Proposal of Objective Criterion in Diagnosis of Abnormalities of Power-Transformer Winding by Frequency Response Analysis

被引:0
作者
Miyazaki, S. [1 ]
Mizutani, Y. [1 ]
Taguchi, A. [2 ]
Murakami, J. [3 ]
Tsuji, N. [4 ]
Takashima, M. [5 ]
Kato, O. [6 ]
机构
[1] Cent Res Inst Elect Power Ind, Yokosuka, Kanagawa, Japan
[2] Kyushu Elect Power Co Inc, Fukuoka, Japan
[3] Tohoku Elect Power Co Inc, Sendai, Miyagi, Japan
[4] Chugoku Elect Power Co Inc, Hiroshima, Japan
[5] Shikoku Elect Power Co Inc, Takamatsu, Kagawa, Japan
[6] Elect Power Dev Co Inc, Chigasaki, Kanagawa, Japan
来源
2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD) | 2016年
关键词
Power Transformer; Winding; Frequency Response Analysis(FRA); Abnormality Diagnosis;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Frequency Response Analysis (FRA) is a powerful technique to detect internal abnormalities within power transformers. However, diagnosis criteria of power transformers by FRA have not been fully established yet. In this paper, an indicator of identification degree of the two transfer functions is examined using data of real transformers and problems in practical application are discussed. Based on this discussion, an improved indicator of degree of identification between two transfer functions is proposed. The proposed indicator is applied to transfer functions of real transformers with or without some abnormalities. Based on this discussion, an objective criterion for diagnosis of abnormalities of transformer windings by FRA is proposed.
引用
收藏
页码:74 / 77
页数:4
相关论文
共 50 条
  • [31] Novel method for detection of transformer winding faults using Sweep Frequency Response Analysis
    Singh, Jashandeep
    Sood, Yog Raj
    Verma, Piush
    Jarial, Raj Kumar
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 2949 - +
  • [32] Interpretation of Sweep Frequency Response Analysis (SFRA) traces for the open circuit and short circuit winding fault damages of the power transformer
    Pandya, Akshay A.
    Parekh, B. R.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 62 : 890 - 896
  • [33] Frequency Response Measurement of a Power Transformer
    Ariastina, W. G.
    Kumara, I. N. S.
    Partha, C. G. Indra
    Arjana, I. G. Dyana
    2015 INTERNATIONAL CONFERENCE QUALITY IN RESEARCH (QIR), 2015, : 102 - 105
  • [34] Deformation Study of a Transformer Winding using Frequency-Response Analysis and Finite-Element Analysis
    Pradhan, Sibabrata
    Nayak, Sisir Kumar
    2022 22ND NATIONAL POWER SYSTEMS CONFERENCE, NPSC, 2022,
  • [35] A Variable Frequency Constant Current Power Supply for Vibration Analysis Method to Detect the Winding Deformation of Power Transformer
    Lu, Q. Y.
    Wang, F. H.
    Jin, Z. J.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [36] Case Studies of Factors Influencing Frequency Response Analysis Measurements and Power Transformer Diagnostics
    Reykherdt, Andrey A.
    Davydov, Valery
    IEEE ELECTRICAL INSULATION MAGAZINE, 2011, 27 (01) : 22 - 30
  • [37] Application of Statistical Interpretation Technique for Frequency Response Analysis and Detection of Axial Displacement in Transformer Winding
    Sardar, Suman
    Kumar, Amrendra
    Chatterjee, Biswendu
    Dalai, Sovan
    2017 IEEE CALCUTTA CONFERENCE (CALCON), 2017, : 461 - 464
  • [38] Study on Diagnosis of Power Transformer Winding Deformation through Vibration Signal
    Zhang, Fan
    Ji, Shengchang
    Shi, Yuhang
    Cui, Yanjie
    Zhu, Lingyu
    Zhu, Yeye
    2016 IEEE INTERNATIONAL POWER MODULATOR AND HIGH VOLTAGE CONFERENCE (IPMHVC), 2016, : 654 - 658
  • [39] Detection of Winding Axial Displacement of a Real Transformer by Frequency Response Analysis without Fingerprint Data
    Miyazaki, Satoru
    ENERGIES, 2022, 15 (01)
  • [40] Modeling of Axial Displacements of Transformer Windings for Frequency Response Analysis Diagnosis
    Trela, Katarzyna
    Gawrylczyk, Konstanty Marek
    ENERGIES, 2024, 17 (13)