Interactions of skin thickness and physicochemical properties of test compounds in percutaneous penetration studies

被引:77
作者
Wilkinson, SC
Maas, WJM
Nielsen, JB
Greaves, LC
van de Sandt, JJM
Williams, FM [1 ]
机构
[1] Newcastle Univ, Sch Clin & Lab Sci, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
[2] TNO Nutr & Food Res, Dept Physiol Sci, NL-3704 HE Zeist, Netherlands
[3] Univ So Denmark, Inst Publ Hlth, DK-5000 Odense C, Denmark
关键词
OECD guideline 428; in vitro percutaneous penetration; lipophilicity;
D O I
10.1007/s00420-005-0056-5
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objectives: To determine the effect of skin thickness on the percutaneous penetration and distribution of test compounds with varying physicochemical properties using in vitro systems. Studies were carried out in accordance with OECD guidelines on skin absorption tests. Methods: Percutaneous penetration of caffeine (log P -0.01), testosterone (log P 3.32), propoxur (log P 1.52) (finite dose in ethanol to water vehicle ratio) and butoxyethanol (log P 0.83) (undiluted finite dose or as an infinite dose 50% [v/v] aqueous solution) through skin of varying thicknesses under occluded conditions was measured using flow through cells for 8-24 h. Saline (adjusted to pH 7.4) was used as receptor fluid, with BSA added for studies with testosterone and propoxur. Following exposure, the remaining surface dose was removed by swabbing and the skin digested prior to scintillation counting. Results: The maximum flux of caffeine was increased with decreasing skin thickness, although these differences were found to be non-significant. The presence of caffeine in the skin membrane was not altered by skin thickness. Maximum flux and cumulative dose absorbed of testosterone and butoxyethanol (in both finite and infinite doses) were markedly reduced with full thickness (about 1 mm thick) skin compared with split thickness skin (about 0.5 mm). Maximum flux of propoxur (dissolved in 60% ethanol) was clearly higher through skin of 0.71 mm than through skin of 1.36 mm, but no difference was found between 0.56 and 0.71 mm. The proportion of propoxur present in the membrane after 24 h increased significantly over the complete range of thicknesses tested (0.56-1.36 mm). Conclusions: A complex relationship exists between skin thickness, lipophilicity and percutaneous penetration and distribution. This has implications for risk assessment studies and for the validation of models with data from different sources.
引用
收藏
页码:405 / 413
页数:9
相关论文
共 24 条
[11]   METHODS FOR INVITRO SKIN ABSORPTION STUDIES OF A LIPOPHILIC TOXIN PRODUCED BY RED TIDE [J].
KEMPPAINEN, BW ;
REIFENRATH, WG ;
STAFFORD, RG ;
MEHTA, M .
TOXICOLOGY, 1991, 66 (01) :1-17
[12]  
Lee FW, 2001, TOXICOLOGY, V168, P63
[13]   Passive skin penetration enhancement and its quantification in vitro [J].
Moser, K ;
Kriwet, K ;
Naik, A ;
Kalia, YN ;
Guy, RH .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2001, 52 (02) :103-112
[14]  
*OECD, 2000, SKIN ABS VITR METH D
[15]  
*OECD, 2000, SKIN ABS VIV METH DR
[16]  
*OECD, 2000, ENVJMTG20005 OECD
[17]  
OECD, 2004, SKIN ABS VITR METH
[18]   PERCUTANEOUS PENETRATION AND SKIN RETENTION OF TOPICALLY APPLIED COMPOUNDS - AN INVITRO-INVIVO STUDY [J].
REIFENRATH, WG ;
HAWKINS, GS ;
KURTZ, MS .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1991, 80 (06) :526-532
[19]  
Riddick J. A., 1986, ORGANIC SOLVENTS PHY, P1325
[20]   Comparative in vitro-in vivo percutaneous absorption of the pesticide propoxur [J].
van de Sandt, JJM ;
Meuling, WJA ;
Elliott, GR ;
Cnubben, NHP ;
Hakkert, BC .