Dual electrode micro-channel flow cell for redox titrations: Kinetics and analysis of homogeneous ascorbic acid oxidation

被引:33
作者
Bitziou, Eleni [1 ]
Snowden, Michael E. [1 ]
Joseph, Maxim B. [2 ]
Leigh, Simon J. [2 ]
Covington, James A. [2 ]
Macpherson, Julie V. [1 ]
Unwin, Patrick R. [1 ]
机构
[1] Univ Warwick, Dept Chem, Coventry CV4 7AL, W Midlands, England
[2] Univ Warwick, Sch Engn, Coventry CV4 7AL, W Midlands, England
关键词
Channel electrode; Dual band electrodes; Catalytic EC ' reaction; Redox titration; Flow cell; Simulations; INTERDIGITATED MICROELECTRODE ARRAY; COLLECTION EFFICIENCY MEASUREMENTS; CHANNEL MICROBAND ELECTRODES; DIFFUSION LAYER TITRATION; BAND ELECTROCHEMICAL-CELL; HYDRODYNAMIC VOLTAMMETRY; STEADY-STATE; MICROFLUIDIC CHANNELS; RING ELECTRODE; IN-SITU;
D O I
10.1016/j.jelechem.2012.12.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A channel flow cell, fabricated using microsterolithography (MSL), has been employed to determine the rate constant for the homogenous oxidation of ascorbic acid (AA) by an electrogenerated oxidant in aqueous solution under physiological pH conditions using a dual gold microband electrode format. Specifically, the oxidation of ferrocenylmethyl trimethyl-ammonium (FcTMA(+)) at an upstream electrode produce FcTMA(2+), which oxidises AA in solution, yielding FcTMA(+) which can undergo further heterogeneous oxidation at the upstream electrode. In addition, by setting the downstream electrode potential to a value where FcTMA(2+) is detected at a transport-limited rate, collection efficiency measurements are also possible in a redox titration format. The benefits of studying homogeneous kinetics, and particularly this catalytic EC' process, in a flow through system using a dual electrode format are highlighted. Collection efficiency measurements are shown to be particularly attractive for the detection of low levels of AA and are much more sensitive than measurements at a single electrode, particularly as a range of device parameters, such as flow rate, electrode size and electrode separation can be tuned to optimise detection. Various electrode sizes operating in the generation/collection (GC) mode have been assessed, with the optimum geometry of those studied (for the highest collection efficiency in the absence of homogenous reactions) being a small upstream generator electrode (25 mu M long), a large downstream collector electrode (400 mu M long), separated by a few tens of microns, in a channel of 200 mu m height and 4 mm width. A full model for the cell hydrodynamics and mass transport has been developed using finite element modelling and extensive experiments are reported assessing the collection efficiency for different electrode geometries and AA concentrations. The homogeneous rate constant for the reaction between FcTMA(2+) and AA is 5.5 (+/- 1.6) x 10(5) M-1 s(-1). (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:72 / 79
页数:8
相关论文
共 59 条
  • [1] Albery W. J., 1971, RING DISC ELECTRODES
  • [2] RING-DISC ELECTRODES .5. FIRST-ORDER KINETIC COLLECTION EFFICIENCIES AT RING ELECTRODE
    ALBERY, WJ
    BRUCKENS.S
    [J]. TRANSACTIONS OF THE FARADAY SOCIETY, 1966, 62 (523P): : 1946 - &
  • [3] THE WALL-JET RING-DISC ELECTRODE .2. COLLECTION EFFICIENCY, TITRATION CURVES AND ANODIC-STRIPPING VOLTAMMETRY
    ALBERY, WJ
    BRETT, CMA
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1983, 148 (02): : 211 - 220
  • [4] Hydrodynamic voltammetry with channel microband electrodes: Axial diffusion effects
    Alden, JA
    Compton, RG
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 404 (01) : 27 - 35
  • [5] The multigrid method, MGD1: An efficient and stable approach to electrochemical modelling. The simulation of double electrode problems
    Alden, JA
    Compton, RG
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 415 (1-2): : 1 - 12
  • [6] Channel microband electrode arrays for mechanistic electrochemistry. Two dimensional voltammetry: Transport-limited currents
    Alden, JA
    Feldman, MA
    Hill, E
    Prieto, F
    Oyama, M
    Coles, BA
    Compton, RG
    Dobson, PJ
    Leigh, PA
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (09) : 1707 - 1720
  • [7] In situ and online monitoring of hydrodynamic flow profiles in microfluidic channels based upon microelectrochemistry: Optimization of electrode locations
    Amatore, C
    Klymenko, OV
    Svir, I
    [J]. CHEMPHYSCHEM, 2006, 7 (02) : 482 - 487
  • [8] Using electrochemical coupling between parallel microbands for in situ monitoring of flow rates in microfluidic channels
    Amatore, C
    Belotti, M
    Chen, Y
    Roy, E
    Sella, C
    Thouin, L
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2004, 573 (02): : 333 - 343
  • [9] Theory and Experiments of Transport at Channel Microband Electrodes under Laminar Flows. 2. Electrochemical Regimes at Double Microband Assemblies under Steady State
    Amatore, Christian
    Da Mota, Nicolas
    Lemmer, Celia
    Pebay, Cecile
    Sella, Catherine
    Thouin, Laurent
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (24) : 9483 - 9490
  • [10] [Anonymous], 2001, ELECTROCHEMICAL METH