Iodine-123 metaiodobenzylguanidine scintigraphy for the assessment of cardiac sympathetic innervation and the relationship with cardiac autonomic function in healthy adults using standardized methods

被引:17
作者
Asghar, Omar [1 ,2 ]
Arumugam, Parthiban [3 ]
Armstrong, Ian [3 ]
Ray, Simon [4 ]
Schmitt, Matthias [4 ]
Malik, Rayaz A. [5 ,6 ]
机构
[1] Univ Manchester, Inst Cardiovasc Sci, Manchester M13 9PL, Lancs, England
[2] Cent Manchester Fdn Trust, Manchester Heart Ctr, Manchester, Lancs, England
[3] Cent Manchester Fdn Trust, Dept Nucl Med, Manchester, Lancs, England
[4] Univ Hosp South Manchester, North West Cardiac Imaging Ctr, Manchester, Lancs, England
[5] Univ Manchester, Inst Human Dev, Manchester, Lancs, England
[6] Weill Cornell Med Coll, Dept Med, Doha, Qatar
关键词
cardiac autonomic neuropathy; cardiac innervation; iodine-123; metaiodobenzylguanidine; scintigraphy; HEART-RATE-VARIABILITY; VENTRICULAR-ARRHYTHMIAS; FAILURE; IMPACT; AGE;
D O I
10.1097/MNM.0000000000000608
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundGlobal iodine-123 metaiodobenzylguanidine (I-123-MIBG) uptake is predictive of cardiovascular events and mortality in patients with heart failure. Normal variations in global and regional uptake, however, are not well defined and few studies have addressed the functional relevance of I-123-MIBG uptake and distribution in healthy individuals.Materials and methodsWe performed I-123-MIBG scintigraphy and cardiac autonomic function testing using the standardized methodology in 15 healthy individuals (mean age 54.65.3 years, male:female 10:5) with no evidence of previous myocardial infarction or ischaemic heart disease.ResultsEarly heart to mediastinum ratio (HMR) was 1.67 +/- 0.13, late HMR was 1.73 +/- 0.16 and washout rate was 19.09 +/- 7.63% (4.20-31.30). Regional analysis showed reduced tracer uptake at the apex, base and inferior wall in all individuals. Early and late HMR correlated negatively with RFa (r=-0.603; P=0.05 and r=-0.644; P=0.033) and expiration and inspiration ratio (r=-0.616; P=0.043 and r=-0.676; P=0.022) and positively with LFa/RFa (r=0.711; P=0.014 and r=0.784; P=0.004). Washout rate correlated only with RFa (r=0.642; P=0.033).ConclusionHealthy adults show a heterogeneous pattern of cardiac innervation with reduced regional uptake of I-123-MIBG. Furthermore, HMR correlates with indices of cardiac sympathetic function, suggesting that it might not only be a useful prognostic marker but may also provide insight into the functional integrity of the cardiac autonomic nervous system.
引用
收藏
页码:44 / 50
页数:7
相关论文
共 34 条
  • [1] Functional anatomy of intrathoracic neurons innervating the atria and ventricles
    Armour, J. Andrew
    [J]. HEART RHYTHM, 2010, 7 (07) : 994 - 996
  • [2] 123I-mIBG Scintigraphy to Predict Inducibility of Ventricular Arrhythmias on Cardiac Electrophysiology Testing A Prospective Multicenter Pilot Study
    Bax, Jeroen J.
    Kraft, Otakar
    Buxton, Alfred E.
    Fjeld, Jan Gunnar
    Parizek, Petr
    Agostini, Denis
    Knuuti, Juhani
    Flotats, Albert
    Arrighi, James
    Muxi, Africa
    Alibelli, Marie-Jeanne
    Banerjee, Gopa
    Jacobson, Arnold F.
    [J]. CIRCULATION-CARDIOVASCULAR IMAGING, 2008, 1 (02) : 131 - 140
  • [3] 131I/123I-metaiodobenzylguanidine (MIBG) scintigraphy:: procedure guidelines for tumour imaging
    Bombardieri, E
    Aktolun, C
    Baum, RP
    Bishof-Delaloye, A
    Buscombe, J
    Chatal, JF
    Maffioli, L
    Moncayo, R
    Mortelmans, L
    Reske, SN
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (12) : BP132 - BP139
  • [4] Cardiac Sympathetic Denervation Assessed With 123-Iodine Metaiodobenzylguanidine Imaging Predicts Ventricular Arrhythmias in Implantable Cardioverter-Defibrillator Patients
    Boogers, Mark J.
    Borleffs, C. Jan Willem
    Henneman, Maureen M.
    van Bommel, Rutger J.
    van Ramshorst, Jan
    Boersma, Eric
    Dibbets-Schneider, Petra
    Stokkel, Marcel P.
    van der Wall, Ernst E.
    Schalij, Martin J.
    Bax, Jeroen J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (24) : 2769 - 2777
  • [5] Carrio I, 2010, EUR J NUCL MED MOL I, V38, P219
  • [6] Cardiac Sympathetic Imaging With mIBG in Heart Failure
    Carrio, Ignasi
    Cowie, Martin R.
    Yamazaki, Junichi
    Udelson, James
    Camici, Paolo G.
    [J]. JACC-CARDIOVASCULAR IMAGING, 2010, 3 (01) : 92 - 100
  • [7] Chen J, 2010, J AM COLL CARDIOL, V55, pA89
  • [8] Variation of heart-to-mediastinal ratio in123I-mIBG cardiac sympathetic imaging: Its affecting factors and potential corrections
    Chen W.
    Cao Q.
    Dilsizian V.
    [J]. Current Cardiology Reports, 2011, 13 (2) : 132 - 137
  • [9] D'Alto M, 1998, Cardiologia, V43, P1231
  • [10] Proposal for standardization of 123I-metaiodobenzylguanidine (MIBG) cardiac sympathetic imaging by the EANM Cardiovascular Committee and the European Council of Nuclear Cardiology
    Flotats, Albert
    Carrio, Ignasi
    Agostini, Denis
    Le Guludec, Dominique
    Marcassa, Claudio
    Schaffers, Michael
    Somsen, G. Aernout
    Unlu, Mustafa
    Verberne, Hein J.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (09) : 1802 - 1812