Diagnostic accuracy of endoscopic ultrasound-guided fine-needle aspiration for solid pancreatic lesion: a systematic review

被引:137
作者
Chen, Jiong [1 ]
Yang, Renbao [1 ]
Lu, Yin [1 ]
Xia, Yunlian [1 ]
Zhou, Hangcheng [1 ]
机构
[1] Anhui Med Univ, Affiliated Prov Hosp, Dept Gen Surg, Hefei, Peoples R China
关键词
Solid pancreatic lesion; Endoscopic ultrasound; Fine-needle aspiration; Diagnosis; Meta-analysis; EUS-FNA; DIFFERENTIAL-DIAGNOSIS; CANCER STATISTICS; BIOPSY; ULTRASONOGRAPHY; MASSES; MANAGEMENT; MALIGNANCY; UTILITY; IMPACT;
D O I
10.1007/s00432-012-1268-1
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To summarize EUS-FNA test performance in suspected pancreatic malignancy with meta-analysis. Two reviewers searched MEDLINE (PubMed and Ovid from January 2002 to January 2012) database to identify relevant studies. The reference lists of the trials were manually searched. Included studies used histopathology or clinical and morphological (CT and MRI and US) follow-up as the "gold standard" and provided sufficient data to construct a diagnostic 2 x 2 table. A statistical program of Meta-Disc was used to calculate the pooled sensitivity, specificity, positive LR, negative LR, DOR, and the SROC curve. Subgroup analysis and meta-regression were calculated to evaluate potential sources of heterogeneity. A total of 15 studies with 1860 patients were included for the analysis. The pooled sensitivity and specificity of EUS-FNA were 92 % (95 % CI = 91-93 %, p < 0.001, I (2) = 69.6 %) and 96 % (95 % CI = 93-98 %, p = 0.006, I (2) = 54.9 %), respectively. The positive LR and negative LR were 14.24 (95 % CI = 7.78-26.07) and 0.09 (95 % CI = 0.07-0.13), respectively. The area under the curve was 0.974. The subgroup analysis of six studies with rapid on-site evaluation (ROSE) showed a pooled sensitivity of 95 % (95 % CI = 93-96 %), with p value equal 0.622 and I (2) = 0. The sensitivity analysis of ten high-quality studies (a score of a parts per thousand yen4) showed a pooled sensitivity of 94 % (95 % CI = 93-96 %, p = 0.144, I (2) = 33.1 %), and the pooled specificity was 0.95 (95 % CI, 0.91-0.97). EUS-FNA had overall excellent specificity and sensitivity in accurately diagnosing solid pancreatic masses. ROSE could help to improve the accuracy of diagnostic test.
引用
收藏
页码:1433 / 1441
页数:9
相关论文
共 39 条
[1]   Prospective evaluation of EUS versus CT scan for staging of ampullary cancer [J].
Artifon, Everson L. A. ;
Couto, Decio, Jr. ;
Sakai, Paulo ;
da Silveira, Eduardo B. .
GASTROINTESTINAL ENDOSCOPY, 2009, 70 (02) :290-296
[2]   Outcomes after preoperative endoscopic ultrasonography and biopsy in patients undergoing distal pancreatectomy [J].
Beane, Joal D. ;
House, Michael G. ;
Cote, Gregory A. ;
DeWitt, John M. ;
Al-Haddad, Mohammad ;
LeBlanc, Julia K. ;
McHenry, Lee ;
Sherman, Stuart ;
Schmidt, C. Max ;
Zyromski, Nicholas J. ;
Nakeeb, Attila ;
Pitt, Henry A. ;
Lillemoe, Keith D. .
SURGERY, 2011, 150 (04) :844-851
[3]  
Bossuyt PM, 2003, CROAT MED J, V44, P639
[4]   Role of endoscopic ultrasound-guided fine-needle aspiration in the diagnosis of solid pancreatic and peripancreatic lesions: is onsite cytopathology necessary? [J].
Cherian, P. Thomas ;
Mohan, Prasoon ;
Douiri, Abdel ;
Taniere, Philippe ;
Hejmadi, Rahul K. ;
Mahon, Brinder S. .
HPB, 2010, 12 (06) :389-395
[5]   Conducting systematic reviews of diagnostic studies: Didactic guidelines [J].
Devillé W.L. ;
Buntinx F. ;
Bouter L.M. ;
Montori V.M. ;
De Vet H.C.W. ;
Van Der Windt D.A.W.M. ;
Bezemer P.D. .
BMC Medical Research Methodology, 2 (1) :1-13
[6]   Endoscopic ultrasound-guided fine needle aspiration biopsy of patients with suspected pancreatic cancer: Diagnostic accuracy and acute and 30-day complications [J].
Eloubeidi, MA ;
Chen, VK ;
Eltoum, IA ;
Jhala, D ;
Chhieng, DC ;
Jhala, N ;
Vickers, SM ;
Wilcox, CM .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2003, 98 (12) :2663-2668
[7]   Endoscopic ultrasound guided fine needle aspiration of solid pancreatic lesions: Performance and outcomes [J].
Fisher, Leon ;
Segarajasingam, Dev Shankar ;
Stewart, Colin ;
Deboer, W. Bastiaan ;
Yusoff, Ian Fuad .
JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2009, 24 (01) :90-96
[8]  
Ghaneh P, 2007, GUT, V56, P1134, DOI 10.1136/gut.2006.103333
[9]   Endosonography-guided fine needle aspiration biopsy in the evaluation of pancreatic masses [J].
Harewood, GC ;
Wiersema, MJ .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2002, 97 (06) :1386-1391
[10]   Measuring inconsistency in meta-analyses [J].
Higgins, JPT ;
Thompson, SG ;
Deeks, JJ ;
Altman, DG .
BMJ-BRITISH MEDICAL JOURNAL, 2003, 327 (7414) :557-560