Quantitative analysis of aberrant protein glycosylation in liver cancer plasma by AAL-enrichment and MRM mass spectrometry

被引:28
作者
Ahn, Yeong Hee [1 ]
Shin, Park Min [1 ]
Kim, Yong-Sam [2 ]
Oh, Na Ree [1 ]
Ji, Eun Sun [1 ]
Kim, Kwang Hoe [1 ,4 ]
Lee, Yeon Jung [3 ]
Kim, Sung Ho [3 ]
Yoo, Jong Shin [1 ,4 ]
机构
[1] Korea Basic Sci Inst, Div Mass Spectrometry, Ochang Eup 363883, Cheongwon Gun, South Korea
[2] Korea Res Inst Biosci & Biotechnol, Canc Biomarkers Dev Res Ctr, Taejon 305806, South Korea
[3] Soonchunhyang Univ, Dept Chem, Asan 336745, South Korea
[4] Chungnam Natl Univ, GRAST, Taejon 305764, South Korea
关键词
LIQUID-CHROMATOGRAPHY; BIOMARKER DISCOVERY; HYDRAZIDE CHEMISTRY; PROSTATE-CANCER; LECTIN; GLYCOPROTEINS; IDENTIFICATION; SERUM; QUANTIFICATION; FUCOSYLATION;
D O I
10.1039/c3an01126g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A lectin-coupled mass spectrometry (MS) approach was employed to quantitatively monitor aberrant protein glycosylation in liver cancer plasma. To do this, we compared the difference in the total protein abundance of a target glycoprotein between hepatocellular carcinoma (HCC) plasmas and hepatitis B virus (HBV) plasmas, as well as the difference in lectin-specific protein glycoform abundance of the target glycoprotein. Capturing the lectin-specific protein glycoforms from a plasma sample was accomplished by using a fucose-specific aleuria aurantia lectin (AAL) immobilized onto magnetic beads via a biotin-streptavidin conjugate. Following tryptic digestion of both the total plasma and its AAL-captured fraction of each HCC and HBV sample, targeted proteomic mass spectrometry was conducted quantitatively by a multiple reaction monitoring (MRM) technique. From the MRM-based analysis of the total plasmas and AAL-captured fractions, differences between HCC and HBV plasma groups in fucosylated glycoform levels of target glycoproteins were confirmed to arise from both the change in the total protein abundance of the target proteins and the change incurred by aberrant fucosylation on target glycoproteins in HCC plasma, even when no significant change occurs in the total protein abundance level. Combining the MRM-based analysis method with the lectin-capturing technique proved to be a successful means of quantitatively investigating aberrant protein glycosylation in cancer plasma samples. Additionally, it was elucidated that the differences between HCC and control groups in fucosylated biomarker candidates A1AT and FETUA mainly originated from an increase in fucosylation levels on these target glycoproteins, rather than an increase in the total protein abundance of the target glycoproteins.
引用
收藏
页码:6454 / 6462
页数:9
相关论文
共 28 条
[1]   A lectin-coupled, targeted proteomic mass spectrometry (MRM MS) platform for identification of multiple liver cancer biomarkers in human plasma [J].
Ahn, Yeong Hee ;
Shin, Park Min ;
Oh, Na Ree ;
Park, Gun Wook ;
Kim, Hoguen ;
Yoo, Jong Shin .
JOURNAL OF PROTEOMICS, 2012, 75 (17) :5507-5515
[2]   A lectin-coupled, multiple reaction monitoring based quantitative analysis of human plasma glycoproteins by mass spectrometry [J].
Ahn, Yeong Hee ;
Shin, Park Min ;
Ji, Eun Sun ;
Kim, Hoguen ;
Yoo, Jong Shin .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (06) :2101-2112
[3]   A multiplex lectin-channel monitoring method for human serum glycoproteins by quantitative mass spectrometry [J].
Ahn, Yeong Hee ;
Ji, Eun Sun ;
Shin, Park Min ;
Kim, Kwang Hoe ;
Kim, Yong-Sam ;
Ko, Jeong Heon ;
Yoo, Jong Shin .
ANALYST, 2012, 137 (03) :691-703
[4]   Comparative Quantitation of Aberrant Glycoforms by Lectin-Based Glycoprotein Enrichment Coupled with Multiple-Reaction Monitoring Mass Spectrometry [J].
Ahn, Yeong Hee ;
Kim, Yong-Sam ;
Ji, Eun Sun ;
Lee, Ji Yeon ;
Jung, Ji-Ae ;
Ko, Jeong Heon ;
Yoo, Jong Shin .
ANALYTICAL CHEMISTRY, 2010, 82 (11) :4441-4447
[5]   Quantitative Analysis of an Aberrant Glycoform of TIMP1 from Colon Cancer Serum by L-PHA-Enrichment and SISCAPA with MRM Mass Spectrometry [J].
Ahn, Yeong Hee ;
Lee, Ji Yeon ;
Lee, Ju Yeon ;
Kim, Yong-Sam ;
Ko, Jeong Heon ;
Yoo, Jong Shin .
JOURNAL OF PROTEOME RESEARCH, 2009, 8 (09) :4216-4224
[6]   Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins [J].
Anderson, L ;
Hunter, CL .
MOLECULAR & CELLULAR PROTEOMICS, 2006, 5 (04) :573-588
[7]   Glycosylation of serum ribonuclease 1 indicates a major endothelial origin and reveals an increase in core fucosylation in pancreatic cancer [J].
Barrabes, Silvia ;
Pages-Pons, Lluis ;
Radcliffe, Catherine M. ;
Tabares, Gloria ;
Fort, Esther ;
Royle, Louise ;
Harvey, David J. ;
Moenner, Michel ;
Dwek, Raymond A. ;
Rudd, Pauline M. ;
De Llorens, Rafael ;
Peracaula, Rosa .
GLYCOBIOLOGY, 2007, 17 (04) :388-400
[8]  
Boja E, 2010, BIOMARK MED, V4, P799, DOI [10.2217/bmm.10.92, 10.2217/BMM.10.92]
[9]   Boronate affinity monolith for highly selective enrichment of glycopeptides and glycoproteins [J].
Chen, Ming ;
Lu, Yang ;
Ma, Qiao ;
Guo, Lin ;
Feng, Yu-Qi .
ANALYST, 2009, 134 (10) :2158-2164
[10]   Identification and Development of Fucosylated Glycoproteins as Biomarkers of Primary Hepatocellular Carcinoma [J].
Comunale, Mary Ann ;
Wang, Mengjun ;
Hafner, Julie ;
Krakover, Jonathan ;
Rodemich, Lucy ;
Kopenhaver, Brent ;
Long, Ronald E. ;
Junaidi, Omer ;
Di Bisceglie, Adrian M. ;
Block, Timothy M. ;
Mehta, Anand S. .
JOURNAL OF PROTEOME RESEARCH, 2009, 8 (02) :595-602