Wave-front coded optical readout for the MEMS-based uncooled infrared imaging systemaf

被引:0
|
作者
Li, Tian [1 ]
Zhao, Yuejin [1 ]
Dong, Liquan [1 ]
Liu, Xiaohua [1 ]
Jia, Wei [1 ]
Hui, Mei [1 ]
Yu, Xiaomei [2 ]
Gong, Cheng [1 ]
Liu, Weiyu [1 ]
机构
[1] Beijing Inst Technol, Sch Optoelect, Beijing 100081, Peoples R China
[2] Peking Univ, Inst Microelect, Natl Key Lab Nano/Micro Fabrica Technol, Beijing 100871, Peoples R China
来源
OPTICAL DESIGN AND TESTING V | 2012年 / 8557卷
基金
中国国家自然科学基金;
关键词
CPM; depth of focus; optical coding; digital decoding; infrared imaging;
D O I
10.1117/12.999386
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In the space limited infrared imaging system based MEMS, the adjustment of optical readout part is inconvenient. This paper proposed a method of wave-front coding to extend the depth of focus/field of the optical readout system, to solve the problem above, and to reduce the demanding for precision in processing and assemblage of the optical readout system itself as well. The wave-front coded imaging system consists of optical coding and digital decoding. By adding a CPM (Cubic Phase Mask) on the pupil plane, it becomes non-sensitive to defocussing within an extended range. The system has similar PSFs and almost equally blurred intermediate images can be obtained. Sharp images are supposed to be acquired based on image restoration algorithms, with the same PSF as a decoding core. We studied the conventional optical imaging system, which had the same optical performance with the wave-front coding one for comparing. Analogue imaging experiments were carried out. And one PSF was used as a simple direct inverse filter, for imaging restoration. Relatively sharp restored images were obtained. Comparatively, the analogue defocussing images of the conventional system were badly destroyed. Using the decrease of the MTF as a standard, we found the depth of focus/field of the wave-front coding system had been extended significantly.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Comprehensive performance analysis of popular odd-symmetric phase masks used for wave-front coded imaging system
    Zhao, Hui
    Li, Yingcai
    OPTICAL DESIGN AND TESTING IV, 2010, 7849
  • [42] Experimental Studies on Improved Vector Extrapolation Richardson-Lucy Algorithm Used to Realize Wave-front Coded Imaging
    Zhao Hui
    Xia Jing-jing
    Zhang Ling
    Fan Xue-wu
    ACTA PHOTONICA SINICA, 2019, 48 (06)
  • [43] Design and Characterization of Fabry-Perot MEMS-Based Short-Wave Infrared Microspectrometers
    Keating, A. J.
    Antoszewski, J.
    Silva, K. K. M. B. D.
    Winchester, K. J.
    Nguyen, T.
    Dell, J. M.
    Musca, C. A.
    Faraone, L.
    Mitra, P.
    Beck, J. D.
    Skokan, M. R.
    Robinson, J. E.
    JOURNAL OF ELECTRONIC MATERIALS, 2008, 37 (12) : 1811 - 1820
  • [44] Design and Characterization of Fabry–Pérot MEMS-Based Short-Wave Infrared Microspectrometers
    A.J. Keating
    J. Antoszewski
    K.K.M.B.D. Silva
    K.J. Winchester
    T. Nguyen
    J.M. Dell
    C.A. Musca
    L. Faraone
    P. Mitra
    J.D. Beck
    M.R. Skokan
    J.E. Robinson
    Journal of Electronic Materials, 2008, 37 : 1811 - 1820
  • [45] Optical design for uniform scanning in MEMS-based 3D imaging lidar
    Lee, Xiaobao
    Wang, Chunhui
    APPLIED OPTICS, 2015, 54 (09) : 2219 - 2223
  • [46] An Optical Readout Method Based on Reflective Filter for Infrared Imaging System
    Wang, Wenjuan
    Hui, Mei
    Gong, Cheng
    Dong, Liquan
    Liu, Ming
    Liu, Xiaohua
    Zhao, Yuejin
    INFRARED, MILLIMETER-WAVE, AND TERAHERTZ TECHNOLOGIES II, 2012, 8562
  • [47] Short-wave infrared, medium-wave infrared, and long-wave infrared imaging study for optical readout microcantilever array infrared sensing system
    Gong, Cheng
    Zhao, Yuejin
    Dong, Liquan
    Hui, Mei
    Yu, Xiaomei
    Liu, Xiaohua
    OPTICAL ENGINEERING, 2013, 52 (02)
  • [48] Method to Measure Transmitting Wave-Front of Imaging Lens Based on Extended Ptychographical Iterative Engine
    Zong Bangming
    Luan Jiayun
    Jiang Zhilong
    Kong Yan
    Wang Shouyu
    Liu Cheng
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2019, 46 (08):
  • [50] Optical study on the vision correction and supernormal vision based on the wave-front aberrations of human eye
    GuoGuang Mu
    ZhaoQi Wang
    YongJi Liu
    Wei Quan
    Yang Wang
    Wei Wang