Evaluation of dose conversion coefficients for an eight-year-old Iranian male phantom undergoing computed tomography

被引:3
作者
Akhlaghi, Parisa [1 ]
Hakimabad, Hashem Miri [1 ]
Motavalli, Laleh Rafat [1 ]
机构
[1] Ferdowsi Univ Mashhad, Fac Sci, Dept Phys, Mashhad 917751436, Iran
关键词
Iranian eight-year-old phantom; Dose conversion coefficients; Computed tomography; Organs depth distributions; PEDIATRIC CT EXAMINATIONS; MONTE-CARLO SIMULATIONS; ADULT MALE; ORGAN; PATIENT; EXPOSURE; FEMALE; MODEL; MDCT;
D O I
10.1007/s00411-015-0607-4
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
In order to construct a library of Iranian pediatric voxel phantoms for radiological protection and dosimetry applications, an Iranian eight-year-old phantom was constructed from a series of CT images. Organ and effective dose conversion coefficients to this phantom were calculated for head, chest, abdominopelvis and chest-abdomen-pelvis scans at tube voltages of 80, 100 and 120 kVp. To validate the results, the organ and effective dose conversion coefficients obtained were compared with those of the University of Florida eight-year-old voxel female phantom as a function of examination type and anatomical scan area. For a detailed study, depth distributions of organs together with the thickness of surrounding tissues located in the beam path, which are shielding the internal organs, were determined for these two voxel phantoms. The relation between the anatomical differences and the level of delivered dose was investigated and the discrepancies among the results justified.
引用
收藏
页码:465 / 474
页数:10
相关论文
共 27 条
[1]   Dose estimation in reference and non-reference pediatric patients undergoing computed tomography examinations: a Monte Carlo study [J].
Akhlaghi, P. ;
Miri-Hakimabad, H. ;
Rafat-Motavalli, L. .
RADIOPROTECTION, 2015, 50 (01) :43-54
[2]   An overview of exposure parameters, dose measurements and strategies for dose reduction in pediatric CT examinations [J].
Akhlaghi, P. ;
Hakimabad, H. Miri ;
Motavalli, L. Rafat .
RADIOPROTECTION, 2014, 49 (01) :9-15
[3]   Dose estimations for Iranian 11-year-old pediatric phantoms undergoing computed tomography examinations [J].
Akhlaghi, Parisa ;
Miri-Hakimabad, Hashem ;
Rafat-Motavalli, Laleh .
JOURNAL OF RADIATION RESEARCH, 2015, 56 (04) :646-655
[4]   Effects of shielding the radiosensitive superficial organs of ORNL pediatric phantoms on dose reduction in computed tomography [J].
Akhlaghi, Parisa ;
Miri-Hakimabad, Hashem ;
Rafat-Motavalli, Laleh .
JOURNAL OF MEDICAL PHYSICS, 2014, 39 (04) :238-246
[5]  
[Anonymous], 2011, 3 INT WORKSH COMP PH
[6]  
[Anonymous], 2002, ICRP PUBL
[7]  
[Anonymous], THESIS U FLORIDA
[8]  
[Anonymous], 2007, Publication, V103
[9]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[10]   An EGS4-ready tomographic computational model of a 14-year-old female torso for calculating organ doses from CT examinations [J].
Caon, M ;
Bibbo, G ;
Pattison, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (09) :2213-2225