Blood flow characteristics in the ascending aorta after aortic valve replacement-a pilot study using 4D-flow MRI

被引:75
作者
von Knobelsdorff-Brenkenhoff, Florian [1 ,2 ]
Trauzeddel, Ralf F. [1 ,2 ]
Barker, Alex J. [3 ]
Gruettner, Henriette [1 ,2 ]
Markl, Michael [3 ,4 ]
Schulz-Menger, Jeanette [1 ,2 ]
机构
[1] Joint Cooperat Charite Med Fac & Max Delbrueck Ct, Expt & Clin Res Ctr, Working Grp Cardiovasc Magnet Resonance, Berlin, Germany
[2] HELIOS Klinikum Berlin Buch, Dept Cardiol & Nephrol, Berlin, Germany
[3] Northwestern Univ, Feinberg Sch Med, Dept Radiol, Chicago, IL 60611 USA
[4] Northwestern Univ, Dept Biomed Engn, McCormick Sch Engn, Chicago, IL 60611 USA
关键词
Aorta; Hemodynamics; Magnetic resonance imaging; Surgery; Valves; 4D-flow; WALL SHEAR-STRESS; PATTERNS; DILATATION; GUIDELINES;
D O I
10.1016/j.ijcard.2013.11.034
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Aortic remodeling after aortic valve replacement (AVR) might be influenced by the postoperative blood flow pattern in the ascending aorta. This pilot study used flow-sensitive four-dimensional magnetic resonance imaging (4D-flow) to describe ascending aortic flow characteristics after various types of AVR. Methods: 4D-flow was acquired in 38 AVR patients (n = 9 mechanical, n = 8 stentless bioprosthesis, n = 14 stented bioprosthesis, n = 7 autograft) and 9 healthy controls. Analysis included grading of vortex and helix flow (0-3 point scale), assessment of systolic flow eccentricity (1-3 point scale), and quantification of the segmental distribution of peak systolic wall shear stress (WSSpeak) in the ascending aorta. Results: Compared to controls, mechanical prostheses showed the most distinct vorticity (2.7 +/- 0.5 vs. 0.7 +/- 0.7; p < 0.001), while stented bioprostheses exhibited most distinct helicity (2.6 +/- 0.7 vs. 1.6 +/- 0.5; p = 0.002). Instead of a physiologic central flow, all stented, stentless and mechanical prostheses showed eccentric flow jets mainly directed towards the right-anterior aortic wall. Stented and stentless prostheses showed an asymmetric distribution of WSSpeak along the aortic circumference, with significantly increased local WSSpeak where the flow jet impinged on the aortic wall. Local WSSpeak was higher in stented (1.4 +/- 0.7 N/m(2)) and stentless (1.3 +/- 0.7 N/m(2)) compared to autografts (0.6 +/- 0.2 N/m(2); p = 0.005 and p = 0.008) and controls (0.7 +/- 0.1 N/m(2); p = 0.017 and p = 0.027). Autografts exhibited lower absolute WSSpeak than controls (0.4 +/- 0.1 N/m(2) vs. 0.7 +/- 0.2 N/m(2); p = 0.003). Conclusions: Flow characteristics in the ascending aorta after AVR are different from native aortic valves and differ between various types of AVR. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:426 / 433
页数:8
相关论文
共 50 条
[41]   The Development of Ascending Aortic Aneurysms After Elective Aortic Valve Replacement With St Jude Mechanical Valve Prosthesis in the Bicuspid Patient: A Pilot Study [J].
Cohoon, Kevin P. ;
Foley, Jillian ;
Dieter, Robert S. ;
Bakhos, Mamdouh ;
Schwartz, Jeffrey .
ANGIOLOGY, 2013, 64 (05) :379-384
[42]   Measurement of cardiac valve and aortic blood flow velocities in stroke patients: a comparison of 4D flow MRI and echocardiography [J].
Thomas Wehrum ;
Felix Guenther ;
Alexander Fuchs ;
Florian Schuchardt ;
Anja Hennemuth ;
Andreas Harloff .
The International Journal of Cardiovascular Imaging, 2018, 34 :939-946
[43]   Quantitative Analysis of Vortical Blood Flow in the Thoracic Aorta Using 4D Phase Contrast MRI [J].
von Spiczak, Jochen ;
Crelier, Gerard ;
Giese, Daniel ;
Kozerke, Sebastian ;
Maintz, David ;
Bunck, Alexander Christian .
PLOS ONE, 2015, 10 (09)
[44]   Aortic flow patterns and wall shear stress maps by 4D-flow cardiovascular magnetic resonance in the assessment of aortic dilatation in bicuspid aortic valve disease [J].
José Fernando Rodríguez-Palomares ;
Lydia Dux-Santoy ;
Andrea Guala ;
Raquel Kale ;
Giuliana Maldonado ;
Gisela Teixidó-Turà ;
Laura Galian ;
Marina Huguet ;
Filipa Valente ;
Laura Gutiérrez ;
Teresa González-Alujas ;
Kevin M. Johnson ;
Oliver Wieben ;
David García-Dorado ;
Arturo Evangelista .
Journal of Cardiovascular Magnetic Resonance, 20
[45]   4-D Flow MRI-Based Computational Analysis of Blood Flow in Patient-Specific Aortic Dissection [J].
Pirola, Selene ;
Guo, Baolei ;
Menichini, Claudia ;
Saitta, Simone ;
Fu, Weiguo ;
Dong, Zhihui ;
Xu, Xiao Yun .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (12) :3411-3419
[46]   Quantification of Retrograde Blood Flow in the Descending Aorta Using Transesophageal Echocardiography in Comparison to 4D Flow MRI [J].
Wehrum, Thomas ;
Kams, Miriam ;
Guenther, Felix ;
Beryl, Primrose ;
Vach, Werner ;
Dragonu, Iulius ;
Harloff, Andreas .
CEREBROVASCULAR DISEASES, 2015, 39 (5-6) :287-292
[47]   Aortic flow patterns and wall shear stress maps by 4D-flow cardiovascular magnetic resonance in the assessment of aortic dilatation in bicuspid aortic valve disease [J].
Rodriguez-Palomares, Jose Fernando ;
Dux-Santoy, Lydia ;
Guala, Andrea ;
Kale, Raquel ;
Maldonado, Giuliana ;
Teixido-Tura, Gisela ;
Galian, Laura ;
Huguet, Marina ;
Valente, Filipa ;
Gutierrez, Laura ;
Gonzalez-Alujas, Teresa ;
Johnson, Kevin M. ;
Wieben, Oliver ;
Garcia-Dorado, David ;
Evangelista, Arturo .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20
[48]   Blood flow dynamics with four-dimensional flow cardiovascular magnetic resonance in patients with aortic stenosis before and after transcatheter aortic valve replacement [J].
Komoriyama, Hirokazu ;
Kamiya, Kiwamu ;
Nagai, Toshiyuki ;
Oyama-Manabe, Noriko ;
Tsuneta, Satonori ;
Kobayashi, Yuta ;
Kato, Yoshiya ;
Sarashina, Miwa ;
Omote, Kazunori ;
Konishi, Takao ;
Sato, Takuma ;
Tsujinaga, Shingo ;
Iwano, Hiroyuki ;
Shingu, Yasushige ;
Wakasa, Satoru ;
Anzai, Toshihisa .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
[49]   Evaluation of Marfan patients status post valve-sparing aortic root replacement with 4D flow [J].
Hope, Thomas A. ;
Kvitting, John-Peder Escobar ;
Hope, Michael D. ;
Miller, D. Craig ;
Markl, Michael ;
Herfkens, Robert J. .
MAGNETIC RESONANCE IMAGING, 2013, 31 (09) :1479-1484
[50]   Network-Based Characterization of Blood Large-Scale Coherent Motion in the Healthy Human Aorta With 4D Flow MRI [J].
Calo, Karol ;
Gallo, Diego ;
Guala, Andrea ;
Rizzini, Maurizio Lodi ;
Dux-Santoy, Lydia ;
Rodriguez-Palomares, Jose ;
Scarsoglio, Stefania ;
Ridolfi, Luca ;
Morbiducci, Umberto .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2023, 70 (03) :1095-1104