Blood flow characteristics in the ascending aorta after aortic valve replacement-a pilot study using 4D-flow MRI

被引:71
作者
von Knobelsdorff-Brenkenhoff, Florian [1 ,2 ]
Trauzeddel, Ralf F. [1 ,2 ]
Barker, Alex J. [3 ]
Gruettner, Henriette [1 ,2 ]
Markl, Michael [3 ,4 ]
Schulz-Menger, Jeanette [1 ,2 ]
机构
[1] Joint Cooperat Charite Med Fac & Max Delbrueck Ct, Expt & Clin Res Ctr, Working Grp Cardiovasc Magnet Resonance, Berlin, Germany
[2] HELIOS Klinikum Berlin Buch, Dept Cardiol & Nephrol, Berlin, Germany
[3] Northwestern Univ, Feinberg Sch Med, Dept Radiol, Chicago, IL 60611 USA
[4] Northwestern Univ, Dept Biomed Engn, McCormick Sch Engn, Chicago, IL 60611 USA
关键词
Aorta; Hemodynamics; Magnetic resonance imaging; Surgery; Valves; 4D-flow; WALL SHEAR-STRESS; PATTERNS; DILATATION; GUIDELINES;
D O I
10.1016/j.ijcard.2013.11.034
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Aortic remodeling after aortic valve replacement (AVR) might be influenced by the postoperative blood flow pattern in the ascending aorta. This pilot study used flow-sensitive four-dimensional magnetic resonance imaging (4D-flow) to describe ascending aortic flow characteristics after various types of AVR. Methods: 4D-flow was acquired in 38 AVR patients (n = 9 mechanical, n = 8 stentless bioprosthesis, n = 14 stented bioprosthesis, n = 7 autograft) and 9 healthy controls. Analysis included grading of vortex and helix flow (0-3 point scale), assessment of systolic flow eccentricity (1-3 point scale), and quantification of the segmental distribution of peak systolic wall shear stress (WSSpeak) in the ascending aorta. Results: Compared to controls, mechanical prostheses showed the most distinct vorticity (2.7 +/- 0.5 vs. 0.7 +/- 0.7; p < 0.001), while stented bioprostheses exhibited most distinct helicity (2.6 +/- 0.7 vs. 1.6 +/- 0.5; p = 0.002). Instead of a physiologic central flow, all stented, stentless and mechanical prostheses showed eccentric flow jets mainly directed towards the right-anterior aortic wall. Stented and stentless prostheses showed an asymmetric distribution of WSSpeak along the aortic circumference, with significantly increased local WSSpeak where the flow jet impinged on the aortic wall. Local WSSpeak was higher in stented (1.4 +/- 0.7 N/m(2)) and stentless (1.3 +/- 0.7 N/m(2)) compared to autografts (0.6 +/- 0.2 N/m(2); p = 0.005 and p = 0.008) and controls (0.7 +/- 0.1 N/m(2); p = 0.017 and p = 0.027). Autografts exhibited lower absolute WSSpeak than controls (0.4 +/- 0.1 N/m(2) vs. 0.7 +/- 0.2 N/m(2); p = 0.003). Conclusions: Flow characteristics in the ascending aorta after AVR are different from native aortic valves and differ between various types of AVR. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:426 / 433
页数:8
相关论文
共 50 条
[31]   Does the AVNeo valve reduce wall stress on the aortic wall? A cardiac magnetic resonance analysis with 4D-flow for the evaluation of aortic valve replacement with the Ozaki technique [J].
Pirola, Sergio ;
Pirola, Selene ;
Mastroiacovo, Giorgio ;
Bonomi, Alice ;
Manchester, Emily L. ;
Fisichella, Serena M. ;
Maragna, Riccardo ;
Baggiano, Andrea ;
Mushtaq, Saima ;
Muscogiuri, Giuseppe ;
Guglielmo, Marco ;
Yun Xu, Xiao ;
Pontone, Gianluca ;
Polvani, Gianluca .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2023, 64 (06)
[32]   Patients With Hypoplastic Left Heart Syndrome Have Abnormal Ascending Aortic Flow Associated With Increased Kinetic Energy Dissipation: Preliminary 4D-Flow MRI Study [J].
Schafer, Michal ;
Mitchell, Max ;
Browne, Lorna ;
Jaggers, James ;
Truong, Uyen ;
Fonseca, Brian ;
Ivy, Dunbar ;
Younoszai, Adel ;
DiMaria, Michael .
CIRCULATION, 2018, 138
[33]   Morphotype-Dependent Flow Characteristics in Bicuspid Aortic Valve Ascending Aortas: A Benchtop Particle Image Velocimetry Study [J].
McNally, Andrew ;
Madan, Ashish ;
Sucosky, Philippe .
FRONTIERS IN PHYSIOLOGY, 2017, 8
[34]   Longitudinal Monitoring of Hepatic Blood Flow before and after TIPS by Using 4D-Flow MR Imaging [J].
Bannas, Peter ;
Roldan-Alzate, Alejandro ;
Johnson, Kevin M. ;
Woods, Michael A. ;
Ozkan, Orhan ;
Motosugi, Utaroh ;
Wieben, Oliver ;
Reeder, Scott B. ;
Kramer, Harald .
RADIOLOGY, 2016, 281 (02) :574-582
[35]   The impact of 4D-Flow MRI spatial resolution on patient-specific CFD simulations of the thoracic aorta [J].
Cherry, Molly ;
Khatir, Zinedine ;
Khan, Amirul ;
Bissell, Malenka .
SCIENTIFIC REPORTS, 2022, 12 (01)
[36]   4D Flow CMR in Assessment of Valve-Related Ascending Aortic Disease [J].
Hope, Michael D. ;
Hope, Thomas A. ;
Crook, Stephen E. S. ;
Ordovas, Karen G. ;
Urbania, Thomas H. ;
Alley, Marc T. ;
Higgins, Charles B. .
JACC-CARDIOVASCULAR IMAGING, 2011, 4 (07) :781-787
[37]   Multiyear Interval Changes in Aortic Wall Shear Stress in Patients with Bicuspid Aortic Valve Assessed by 4D Flow MRI [J].
Maroun, Anthony ;
Scott, Michael B. ;
Catania, Roberta ;
Berhane, Haben ;
Jarvis, Kelly ;
Allen, Bradley D. ;
Barker, Alex J. ;
Markl, Michael .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 60 (06) :2580-2589
[38]   Blood flow characteristics after aortic valve neocuspidization in paediatric patients: a comparison with the Ross procedure [J].
Secinaro, Aurelio ;
Milano, Elena Giulia ;
Ciancarella, Paolo ;
Trezzi, Matteo ;
Capelli, Claudio ;
Ciliberti, Paolo ;
Cetrano, Enrico ;
Curione, Davide ;
Santangelo, Teresa Pia ;
Napolitano, Carmela ;
Albanese, Sonia B. ;
Carotti, Adriano .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2022, 23 (02) :275-282
[39]   Evaluating a Phase-Specific Approach to Aortic Flow: A 4D Flow MRI Study [J].
Ramaekers, Mitch J. F. G. ;
Westenberg, Jos J. M. ;
Venner, Max F. G. H. M. ;
Juffermans, Joe F. ;
van Assen, Hans C. ;
te Kiefte, Bastiaan J. C. ;
Adriaans, Bouke P. ;
Lamb, Hildo J. ;
Wildberger, Joachim E. ;
Schalla, Simon .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 59 (03) :1056-1067
[40]   Verification Study of In Silico Computed Intracardiac Blood Flow With 4D Flow MRI [J].
Obermeier, L. ;
Wiegand, M. ;
Hellmeier, F. ;
Manini, C. ;
Kuehne, T. ;
Goubergrits, L. ;
Vellguth, K. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2024, 71 (09) :2568-2579