3D MR angiography of renal arteries: Comparison of volume rendering and maximum intensity projection algorithms

被引:36
作者
Mallouhi, A [1 ]
Schocke, M [1 ]
Judmaier, W [1 ]
Wolf, C [1 ]
Dessl, A [1 ]
Czermak, BV [1 ]
Waldenberger, P [1 ]
Jaschke, WR [1 ]
机构
[1] Univ Innsbruck Hosp, Dept Radiol, A-6020 Innsbruck, Austria
关键词
magnetic resonance (MR); vascular studies; renal arteries; MR; stenosis or obstruction;
D O I
10.1148/radiol.2231010858
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare volume rendering (VR) and maximum intensity projection (MIP) as postprocessing techniques of magnetic resonance (MR) angiography for detection and quantification of renal artery stenosis. MATERIALS AND METHODS: Twenty-seven patients underwent three-dimensional contrast material-enhanced MR angiography of the renal arteries with a 1.5-T imager. For each renal artery, targeted MIP and VR images were reconstructed in oblique coronal and transverse orientations. For each modality, image generation and evaluation were performed interactively by two independent radiologists blinded to angiographic results. In comparison with digital subtraction angiography (DSA) findings, stenosis quantification and detection by using MIP and VIR were evaluated with the use of 50% and 70% cutoff points by using linear regression analysis and 2 X 2 tables. Overall image quality and vascular delineation on MIP and VR images were also compared. RESULTS: All main and accessory renal arteries depicted at DSA were also demonstrated on MIP and VR images. VR performed slightly better than MIP for quantification of stenoses greater than 50% (VR: r(2) = 0.84, P < .001; MIP: r(2) = 0.38, P = .001) and significantly better for severe stenoses (VR: r(2) = 0.83, P < .001; MIP: r(2) = 0.21, P = .1). For detection of stenosis, VR yielded a substantial improvement in positive predictive value (VR: 95% and 90%; MIP: 86% and 68% for stenoses greater than 50% and 70%, respectively). Image quality obtained with VR was not significantly better than that with MIP; however, vascular delineation on VR images was significantly better. CONCLUSION: The VR technique of renal MR angiography enabled more accurate detection and quantification of renal artery stenosis than did MIP, with significantly improved vascular delineation. (C) RSNA, 2002.
引用
收藏
页码:509 / 516
页数:8
相关论文
共 38 条
[1]   Stent placement in ostial and nonostial atherosclerotic renal arterial stenoses: A prospective follow-up study [J].
Baumgartner, I ;
von Aesch, K ;
Do, DD ;
Triller, J ;
Birrer, M ;
Mahler, F .
RADIOLOGY, 2000, 216 (02) :498-505
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Treatment of ostial renal-artery stenoses with vascular endoprostheses after unsuccessful balloon angioplasty [J].
Blum, U ;
Krumme, B ;
Flugel, P ;
Gabelmann, A ;
Lehnert, T ;
BuitragoTellez, C ;
Schollmeyer, P ;
Langer, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (07) :459-465
[4]   Postprocessing techniques for gadolinium-enhanced three-dimensional MR angiography [J].
Davis, CP ;
Hany, TF ;
Wildermuth, S ;
Schmidt, M ;
Debatin, JF .
RADIOGRAPHICS, 1997, 17 (05) :1061-1077
[5]   Renal arterial stenosis: Prospective comparison of color Doppler US and breath-hold, three-dimensional, dynamic, gadolinium-enhanced MR angiography [J].
De Cobelli, F ;
Venturini, M ;
Vanzulli, A ;
Sironi, S ;
Salvioni, M ;
Angeli, E ;
Scifo, P ;
Garancini, MP ;
Quartagno, R ;
Bianchi, G ;
Del Maschio, A .
RADIOLOGY, 2000, 214 (02) :373-380
[6]   Renal artery stenosis: Evaluation with breath-hold, three-dimensional, dynamic, gadolinium-enhanced versus three-dimensional, phase-contrast MR angiography [J].
DeCobelli, F ;
Vanzulli, A ;
Sironi, S ;
Mellone, R ;
Angeli, E ;
Venturini, M ;
Garancini, MP ;
Quartagno, R ;
Bianchi, G ;
DelMaschio, A .
RADIOLOGY, 1997, 205 (03) :689-695
[7]   Diagnosis of renal vascular disease with MR angiography [J].
Dong, Q ;
Schoenberg, SO ;
Carlos, RC ;
Neimatallah, M ;
Cho, KJ ;
Williams, DM ;
Kazanjian, SN ;
Prince, MR .
RADIOGRAPHICS, 1999, 19 (06) :1535-1554
[8]   High-spatial-resolution contrast-enhanced MR angiography of the renal arteries: A prospective comparison with digital subtraction angiography [J].
Fain, SB ;
King, BF ;
Breen, JF ;
Kruger, DG ;
Riederer, SJ .
RADIOLOGY, 2001, 218 (02) :481-490
[9]  
Floemer F, 2000, RADIOLOGE, V40, P246, DOI 10.1007/s001170050665
[10]   Diagnostic impact of four postprocessing techniques in evaluating contrast-enhanced three-dimensional MR angiography [J].
Hany, TF ;
Schmidt, M ;
Davis, CP ;
Göhde, SC ;
Debatin, JF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (04) :907-912