Numerical analysis of Peltier current lead

被引:0
作者
Sato, K [1 ]
Okumura, H [1 ]
Yamaguchi, S [1 ]
机构
[1] Arasat Corp, Tokyo 1500031, Japan
来源
TWENTIETH INTERNATIONAL CONFERENCE ON THERMOELECTRICS, PROCEEDINGS | 2001年
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Peltier current leads (PCL) are numerically analyzed. We solve a one-dimensional heat conduction equation to study the thermal behavior of a variety of PCLs under various cooling conditions. The PCLs consist of a thermoelectric element inserted into a copper lead at its room temperature end, with or without a high-T-c superconductor below 77 K. Thermoelectric elements of both p- and n-types. and pure copper are Utilized as constituent parts of the PCLs. Each part of the PCL is cooled with either a helium or nitro.-en gas under the self-cooling condition. Due to the Peltier effect, the PCLs are expected to exhibit less heat leak at the low temperature end than conventional current leads. Our calculations confirm that the PCLs show as much as 30% reductions of the heat leak when they are optimized. Temperature profiles and other physical quantities of interest are also computed.
引用
收藏
页码:491 / 494
页数:4
相关论文
共 50 条
[31]   Numerical Analysis of AIMD Lead Tolerances Using the Lead Electromagnetic Model [J].
Kozlov, Mikhail ;
Kainz, W. .
2019 USNC-URSI RADIO SCIENCE MEETING (JOINT WITH AP-S SYMPOSIUM), 2019, :41-42
[32]   ON-CHIP PELTIER COOLING USING CURRENT PULSE [J].
Gupta, Man Prakash ;
Sayer, Min-hee S. ;
Mukhopadhyay, Saibal ;
Kumar, Satish .
2010 12TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, 2010,
[33]   Possibility of a gas-cooled Peltier current lead in the 200 m-class superconducting direct current transmission and distribution system of CASER-2 [J].
Kawahara, Toshio ;
Emoto, Masahiko ;
Watanabe, Hirofumi ;
Hamabe, Makoto ;
Yamaguchi, Sataro ;
Hikichi, Yasuo ;
Minowa, Masahiro .
ADVANCES IN SUPERCONDUCTIVITY XXIV, 2012, 27 :380-383
[34]   NUMERICAL MODEL FOR CONDUCTION-COOLED CURRENT LEAD HEAT LOADS [J].
White, M. J. ;
Brueck, H. D. ;
Wang, X. L. .
ADVANCES IN CRYOGENIC ENGINEERING, VOLS 57A AND 57B, 2012, 1434 :565-572
[35]   Steady state and transient current lead analysis [J].
Citver, G. ;
Barzi, E. ;
Burov, A. ;
Feher, S. ;
Limon, P.J. ;
Peterson, T. .
IEEE Transactions on Applied Superconductivity, 1999, 9 (2 I) :515-518
[36]   Numerical Examination of the Performance of a Thermoelectric Cooler with Peltier Heating and Cooling [J].
Kim, Chang Nyung ;
Kim, Jeongho .
JOURNAL OF ELECTRONIC MATERIALS, 2015, 44 (10) :3586-3591
[37]   Performance analysis of nanostructured Peltier coolers [J].
Singha, Aniket ;
Muralidharan, Bhaskaran .
JOURNAL OF APPLIED PHYSICS, 2018, 124 (14)
[38]   Numerical Examination of the Performance of a Thermoelectric Cooler with Peltier Heating and Cooling [J].
Chang Nyung Kim ;
Jeongho Kim .
Journal of Electronic Materials, 2015, 44 :3586-3591
[39]   On the optimal design of gas-cooled Peltier current leads [J].
Xuan, XC .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2003, 13 (01) :48-53
[40]   Structural analysis of relationships amongst bone lead, cumulative blood lead and current blood lead [J].
Brito, JAA ;
Fleming, DEB ;
Chettle, DR .
EDXRS-98: PROCEEDINGS OF THE EUROPEAN CONFERENCE ON ENERGY DISPERSIVE X-RAY SPECTROMETRY 1998, 1999, :235-239