Forearm extensor and flexor muscle exertion during simulated gripping work - An electromyographic study

被引:79
作者
Hagg, GM [1 ]
Milerad, E [1 ]
机构
[1] PAIN CLIN KRONAN,STOCKHOLM,SWEDEN
关键词
EMG; fatigue; lateral epicondylitis; forearm;
D O I
10.1016/S0268-0033(96)00049-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To study forearm muscular exertion during intermittent gripping work at three different regimes resembling vocational work. Design. An electromyographic laboratory study of forearm fatigue during intermittent gripping work at 25% MVC with 10/10, 20/10 and 30/10 s of work/rest was performed. Background. Data from the literature indicate that forearm flexors as well as extensors are activated during gripping. However, no systematic quantitative assessment of the muscular exertion has been made hitherto. Methods. Nine female subjects participated. EMG was detected from five forearm muscles, three extensors and two flexors. Zero crossing rate alterations were used as an index of fatigue. Results. The results show significant (P<0.05) fatigue signs in at least two of the extensor muscles at all regimes while significant signs of fatigue was seen only at the 30/10 regime for the flexor muscles. Conclusions. Fatigue effects are generally larger on the extensor side. None of the studied regimes is acceptable from EMG fatigue point of view.
引用
收藏
页码:39 / 43
页数:5
相关论文
共 23 条
  • [1] [Anonymous], 1993, CRIT REV PHYS REHABI
  • [2] METHODOLOGY FOR DOCUMENTING HAND POSITIONS AND FORCES DURING MANUAL WORK
    ARMSTRONG, TJ
    CHAFFIN, DB
    FOULKE, JA
    [J]. JOURNAL OF BIOMECHANICS, 1979, 12 (02) : 131 - 133
  • [3] BASMAJIAN JV, 1985, MUSCLES ALIVE
  • [4] PHYSIOLOGICAL-EFFECTS OF MICROPAUSES IN ISOMETRIC HANDGRIP EXERCISE
    BYSTROM, SEG
    MATHIASSEN, SE
    FRANSSONHALL, C
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1991, 63 (06): : 405 - 411
  • [5] PHYSIOLOGICAL-RESPONSE IN THE FOREARM DURING AND AFTER ISOMETRIC INTERMITTENT HANDGRIP
    BYSTROM, SEG
    KILBOM, A
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1990, 60 (06): : 457 - 466
  • [6] MEDIAN FREQUENCY OF THE MYOELECTRIC SIGNAL - EFFECTS OF HAND DOMINANCE
    DE LUCA, CJ
    SABBAHI, MA
    ROY, SH
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1986, 55 (05) : 457 - 464
  • [7] EVALUATION OF HANDGRIP FORCE FROM EMG MEASUREMENTS
    DUQUE, J
    MASSET, D
    MALCHAIRE, J
    [J]. APPLIED ERGONOMICS, 1995, 26 (01) : 61 - 66
  • [8] FranssonHall C, 1996, AM J IND MED, V29, P15, DOI 10.1002/(SICI)1097-0274(199601)29:1<15::AID-AJIM3>3.0.CO
  • [9] 2-Y
  • [10] HAGBERG M, 1981, J APPL PHYSIOL, V51, P1