Prediction and measurement of axial flow fan aerodynamic and aeroacoustic performance in a split-type air-conditioner outdoor unit

被引:26
作者
Zhao, Xifeng [1 ]
Sun, Jinju [1 ]
Zhang, Zhi [2 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Xian 710049, Peoples R China
[2] Midea Air Conditioning & Refrigerat Grp Co Ltd, Ctr Inst, Foshan 528311, Peoples R China
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2013年 / 36卷 / 03期
关键词
Air conditioner; Outdoor unit; Axial flow fan; Computational fluid dynamics; Computational aerodynamic acoustics; Noise reduction; NOISE-REDUCTION;
D O I
10.1016/j.ijrefrig.2012.11.024
中图分类号
O414.1 [热力学];
学科分类号
摘要
The study has focused on outdoor unit noise reduction by fan geometry modification with the refined numerical and experimental approaches. The outlet louver, electric motor and its support are included to refine the flow and acoustic model and a hybrid method incorporating CFD and CAA is used to predict the noise behavior. The fan performance curve is well-predicted; the moderate acoustic power is obtained on the outlet louver, motor support and motor exhibiting a significant contribution to overall noise behavior. The aeroacoustic test is conducted in an anechoic chamber and the obtained results are compared with the semi-anechoic chamber ones, and the unremarkable differences are produced, which indicate the ground floor being of some influence. Both modified fan geometries are effective to reduce the noise but the flanging outer-edge blade is more effective. The noise directivities of three geometry fans are investigated both numerically and experimentally and the produced asymmetric characteristics are analyzed. (C) 2012 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:1098 / 1108
页数:11
相关论文
共 15 条
[1]  
[Anonymous], FLUENT VERS 6 3 US G
[2]   Discrete noise prediction of variable pitch cross-flow fans by unsteady Navier-Stokes computations [J].
Cho, Y ;
Moon, YJ .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (03) :543-550
[3]   Development of low-noise centrifugal fans for a refrigerator using inclined S-shaped trailing edge [J].
Heo, Seung ;
Cheong, Cheolung ;
Kim, Tae-Hoon .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (08) :2076-2091
[4]  
ISO, 2003, Tech. Rep. 3745
[5]  
*ISO, 1997, 5801 ISO
[6]   Experimental and numerical study on aeroacoustic sound of axial flow fan in room air conditioner [J].
Jiang Cai-ling ;
Chen Jiang-ping ;
Chen Zhi-jiu ;
Tian Jie ;
Hua, OuYang ;
Du Zhao-Hui .
APPLIED ACOUSTICS, 2007, 68 (04) :458-472
[7]   Investigation of air-flow fields and aeroacoustic noise in outdoor unit for split-type air conditioner [J].
Jiang, Cai-Ling ;
Tian, Jie ;
Ouyang, Hua ;
Chen, Jiang-Ping ;
Chen, Zhi-Jiu .
NOISE CONTROL ENGINEERING JOURNAL, 2006, 54 (03) :146-156
[8]   Prediction and reduction of internal blade-passing frequency noise of the centrifugal fan in a refrigerator [J].
Lee, Seungyub ;
Heo, Seung ;
Cheong, Cheolung .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2010, 33 (06) :1129-1141
[9]   REVIEW OF NOISE-REDUCTION METHODS FOR CENTRIFUGAL FANS [J].
NEISE, W .
JOURNAL OF ENGINEERING FOR INDUSTRY-TRANSACTIONS OF THE ASME, 1982, 104 (02) :151-161
[10]   NOISE-REDUCTION IN CENTRIFUGAL FANS - LITERATURE SURVEY [J].
NEISE, W .
JOURNAL OF SOUND AND VIBRATION, 1976, 45 (03) :375-403