A novel singlemode-multimode-thinned-singlemode (SMTS) fiber structure based Mach-Zehnder interferometer (MZI) is proposed for measurements of liquid level and refractive index (RI). We observe that the liquid RI information can be provided from the sensitivity of the interference peak shifts. Furthermore, by measuring the certain wavelength shift, the liquid level can be measured accordingly. A 9.00 mm-long thinned fiber with core/cladding diameters of around 4.5/80 mu m is used. The wavelength of 1538.7228 nm exhibits a water level sensitivity of -175.8 pm/mm, and refractive index sensitivity of -1868.42 (pm/mm) / RIU, respectively. Moreover, the fabrication process is very simple and cost effective.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] A Hybrid Mach-Zehnder Interferometer for Refractive Index and Temperature Measurement
    Ni, Xiaoqi
    Wang, Ming
    Guo, Dongmei
    Hao, Hui
    Zhu, Jiali
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2016, 28 (17) : 1850 - 1853
  • [32] Measuring the refractive index of scintillation crystal with a Mach-Zehnder interferometer
    Liu, Xinyue
    Long, Jiale
    Ding, Yi
    Hu, Yi
    Du, Zihao
    Xu, Bin
    Deng, Dingnan
    OPTICS CONTINUUM, 2022, 1 (04): : 909 - 918
  • [33] Microcavity Mach-Zehnder Interferometer Sensors for Refractive Index Sensing
    Dong, Xin-Ran
    Sun, Xiao-Yan
    Chu, Dong-Kai
    Yin, Kai
    Luo, Zhi
    Zhou, Chu
    Wang, Cong
    Hu, You-Wang
    Duan, Ji-An
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2016, 28 (20) : 2285 - 2288
  • [34] Optimization of cascaded fiber tapered Mach-Zehnder interferometer and refractive index sensing technology
    Wang, Qi
    Wei, Wenqing
    Guo, Mengjuan
    Zhao, Yong
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 222 : 159 - 165
  • [35] Simultaneous refractive index and temperature measurements by using dual interference in an all-fiber Mach-Zehnder interferometer
    Yan, Xu
    Fu, Haiwei
    Li, Huidong
    Qiao, Xueguang
    CHINESE OPTICS LETTERS, 2016, 14 (03)
  • [36] Refractive index and temperature sensor based on Mach-Zehnder interferometer with thin fibers
    Liu, Wei
    Wu, Xuqiang
    Zhang, Gang
    Li, Shili
    Zuo, Cheng
    Fang, Shasha
    Yu, Benli
    OPTICAL FIBER TECHNOLOGY, 2020, 54
  • [37] Ultracompact and high sensitive refractive index sensor based on Mach-Zehnder interferometer
    Yu, Huaqing
    Xiong, Liangbin
    Chen, Zhihong
    Li, Qianguang
    Yi, Xunong
    Ding, Yu
    Wang, Feng
    Lv, Hao
    Ding, Yaoming
    OPTICS AND LASERS IN ENGINEERING, 2014, 56 : 50 - 53
  • [38] Simultaneous measurement of refractive index and temperature with high sensitivity based on a multipath fiber Mach-Zehnder interferometer
    Jiang, Yajun
    Wang, Tao
    Liu, Chi
    Feng, Dingyi
    Jiang, Bichang
    Yang, Dexing
    Zhao, Jianlin
    APPLIED OPTICS, 2019, 58 (15) : 4085 - 4090
  • [39] Refractive index sensor using microfiber-based Mach-Zehnder interferometer
    Wo, Jianghai
    Wang, Guanghui
    Cui, Ying
    Sun, Qizhen
    Liang, Ruibing
    Shum, Perry Ping
    Liu, Deming
    OPTICS LETTERS, 2012, 37 (01) : 67 - 69
  • [40] Ultrasensitive refractive index sensor based on a Mach-Zehnder interferometer created in twin-core fiber
    Li, Zhengyong
    Liao, Changrui
    Wang, Yiping
    Dong, Xiaopeng
    Liu, Shen
    Yang, Kaiming
    Wang, Qiao
    Zhou, Jiangtao
    OPTICS LETTERS, 2014, 39 (17) : 4982 - 4985