Methods for glomerular quantification in dogs: a comparative study

被引:0
|
作者
Leles Costa, Caio Augusto [1 ]
de Lima, Charles Silva [1 ]
Ramirez Uscategui, Ricardo Andres [2 ]
Barros Silva, Gyl Eanes [3 ]
Crivellenti, Leandro Zuccolotto [1 ]
机构
[1] Univ Franca UNIFRAN, Hosp Vet, Programa Posgrad Ciencia Anim, BR-14404600 Franca, SP, Brazil
[2] Univ Sao Paulo UNESP, Dept Clin & Cirurgia Vet, Jaboticabal, SP, Brazil
[3] Univ Sao Paulo, Fac Med Ribeirao Preto, Dept Patol Renal, Sao Paulo, SP, Brazil
来源
CIENCIA RURAL | 2019年 / 49卷 / 03期
基金
巴西圣保罗研究基金会;
关键词
glomerulopathy; histopathology; light microscopy; RENAL BIOPSY; PATHOLOGICAL EVALUATION; DISEASE;
D O I
10.1590/0103-8478cr20180851
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
It was evaluated the different methodologies for glomerular enumeration described in the literature in a quantitative, double-blind study on the number of glomeruli present in kidney biopsy specimens obtained using a Tru-cut-type biopsy needle. Eighteen samples were taken (n-18) from various regions of canine kidneys harvested immediately after euthanasia. Sample collection was carried out using Tru-cut-type, semi-automated, 16 gauge needles. Reading and evaluation of the specimens were performed independently by four researchers by means of eye loupe inspection, light microscopy, light microscopy with a reduced condenser aperture, and dissection microscopy Samples were also subjected to histopathological evaluation for comparison purposes. There was no inter-researcher variation for any of the tested methods. The glomerular counts obtained using light microscopy with reduced condenser aperture were similar to those reported in the histopathological evaluation (P=0.44): whereas, the other glomerular enumeration methods yielded significantly lower counts when compared to the histopathological analysis (eye loupe inspection: P<0.01; conventional light microscopy: P-0.02; dissection microscopy: P<0.01).Light microscope with lowering of the condenser lens delivers better results than conventional light microscopy and eye loupe inspection. Results obtained using dissection microscopy and eye loupe inspection did not correlate well with those provided by histopathological evaluation: consequently, these two methods should be avoided.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] COMPARATIVE QUANTIFICATION OF NEURITIC PLAQUES WITH BIELSCHOWSKY AND IMMUNOSTAINING METHODS
    WEN, GY
    KIM, KS
    WISNIEWSKI, HM
    JOURNAL OF NEUROPATHOLOGY AND EXPERIMENTAL NEUROLOGY, 1988, 47 (03): : 343 - 343
  • [22] Comparative analysis of localization and quantification methods of local defects
    Legay, F
    Monteil, G
    Roques-Carmes, C
    Zwilling, V
    MEASURE AND QUALITY CONTROL IN PRODUCTION, 2004, 1860 : 215 - 221
  • [23] Comparative Assessment of Quantification Methods for Tumor Tissue Phosphoproteomics
    Zhang, Yang
    Dreyer, Benjamin
    Govorukhina, Natalia
    Heberle, Alexander M.
    Koncarevic, Sasa
    Krisp, Christoph
    Opitz, Christiane A. .
    Pfander, Pauline
    Bischoff, Rainer
    Schlueter, Hartmut
    Kwiatkowski, Marcel
    Thedieck, Kathrin
    Horvatovich, Peter L.
    ANALYTICAL CHEMISTRY, 2022, 94 (31) : 10893 - 10906
  • [24] ANALYTICAL METHODS FOR THE QUANTIFICATION OF RITONAVIR IN PHARMACEUTICALS, A COMPARATIVE EVALUATION
    Akbel, Erten
    BULLETIN OF THE CHEMICAL SOCIETY OF ETHIOPIA, 2022, 36 (04) : 737 - 747
  • [25] LIGHT AND ELECTRON MICROSCOPICAL STUDY OF GLOMERULAR LIPOIDOSIS IN BEAGLE DOGS
    ZAYED, I
    GOPINATH, C
    HORNSTRA, HW
    SPIT, BJ
    HEIJDEN, CA
    JOURNAL OF COMPARATIVE PATHOLOGY, 1976, 86 (04) : 509 - 517
  • [26] A COMPARATIVE STUDY OF BLOOD VOLUME IN DOGS
    KRIEGER, H
    STORAASLI, JP
    FRIEDELL, HL
    HOLDEN, WD
    PROCEEDINGS OF THE SOCIETY FOR EXPERIMENTAL BIOLOGY AND MEDICINE, 1948, 68 (03): : 511 - 515
  • [27] Computerized electrocardiography in dogs: a comparative study
    Oliveira, Lidia S.
    Santos, Roberto R. B.
    Melo, Marcos B.
    Larangeira, Daniela F.
    Barrouin-Melo, Stella Maria
    PESQUISA VETERINARIA BRASILEIRA, 2013, 33 (07): : 949 - 953
  • [28] Comparative study of calibration methods for quantification of alpha-emitting radionuclides (plutonium) by semiconductor detectors
    Toribio, M
    Garcia, JF
    IzquierdoRidorsa, A
    Rauret, G
    Coll, A
    Valles, I
    Ortega, X
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1997, 221 (1-2) : 73 - 78
  • [29] Comparative study of calibration methods for quantification of alpha-emitting radionuclides (plutonium) by semiconductor detectors
    M. Toribio
    J. F. García
    A. Izquierdo-Ridorsa
    G. Rauret
    A. Coll
    I. Vallés
    X. Ortega
    Journal of Radioanalytical and Nuclear Chemistry, 1997, 221 : 73 - 78
  • [30] A Comparative Study of Different Collimation Methods for Quantification of Required Skin Margin During Electron Treatment
    Shrestha, N.
    Brenner, M.
    Narayanasamy, G.
    Morrill, S.
    Su, Z.
    Lewis, G.
    Kalantari, F.
    MEDICAL PHYSICS, 2021, 48 (06)