Development of an amperometric sensor for simultaneous determination of uric acid and ascorbic acid using 2-[bis(2-aminoethyl)amino]ethanol, 4,4′- bipyridine bridged dicopper(II) complex

被引:9
作者
Wang, Ming Yan [1 ,2 ]
Xu, Xing You [1 ,2 ]
Yang, Fan [1 ]
Zhang, Sheng Yu [1 ]
Yang, Xu Jie [2 ]
机构
[1] Huaihai Inst Technol, Dept Chem Engn, Lianyungang 222005, Jiangsu Prov, Peoples R China
[2] Nanjing Univ Sci & Technol, Lab Mat Chem, Nanjing 210094, Peoples R China
关键词
binuclear copper complex; uric acid; ascorbic acid; modified electrode; cyclic voltammetry; differential pulse voltammetry;
D O I
10.1007/s10800-008-9552-0
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Binuclear copper complex (2-[bis(2-aminoethyl)amino]ethanol, 4,4'-bipyridine bridged dicopper(II) complex) was grafted onto the surface of a glassy carbon electrode (GCE) using the cyclic voltammetric method in a phosphate buffer solution (PBS). The modified electrode resulted in efficient electrocatalytic activity for anodic oxidation of uric acid (UA) and ascorbic acid (AA) via a substantial decrease in anodic over-potentials for both compounds. Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) using this modified electrode result in two well-resolved anodic waves for the oxidation of UA and AA in mixed solution, making possible the simultaneous determination of both compounds. Linear analytical curves were obtained in the ranges 5.0-300.0 mu M and 5.0-160.0 mu M for UA and AA concentrations through DPV methods, respectively. The detection limits were 2.0 mu M of UA and AA. This electrode was used for UA and AA determinations in urine samples with satisfactory results.
引用
收藏
页码:1269 / 1274
页数:6
相关论文
共 23 条
[1]   Cobalt(II) salophen-modified carbon-paste electrode for potentiometric and voltammetric determination of cysteine [J].
Amini, MK ;
Khorasani, JH ;
Khaloo, SS ;
Tangestaninejad, S .
ANALYTICAL BIOCHEMISTRY, 2003, 320 (01) :32-38
[2]  
BARD AJ, 1980, ELECTROCHEMICAL METH
[3]  
GSWARA DVS, 1974, ANAL CHEM, V46, P1777
[4]   Detection of serum uric acid using the optical polymeric enzyme biochip system [J].
Huang, SH ;
Shih, YC ;
Wu, CY ;
Yuan, CJ ;
Yang, YS ;
Li, YK ;
Wu, TK .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (12) :1627-1633
[5]   Novel choline and acetylcholine modified glassy carbon electrodes for simultaneous determination of dopamine, serotonin and ascorbic acid [J].
Jin, GP ;
Lin, XQ ;
Gong, JM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2004, 569 (01) :135-142
[6]   Monolayer covalent modification of 5-hydroxytryptophan on glassy carbon electrodes for simultaneous determination of uric acid and ascorbic acid [J].
Lin, Xiangqin ;
Li, Yongxin .
ELECTROCHIMICA ACTA, 2006, 51 (26) :5794-5801
[7]   Electrocatalytic oxidation and selective detection of dopamine at a 5,5-ditetradecyl-2-(2-trimethyl-ammonioethyl)-1,3-dioxane bromide self-assembled bilayer membrane modified glassy carbon electrode [J].
Lin, XQ ;
Gong, JM .
ANALYTICA CHIMICA ACTA, 2004, 507 (02) :255-261
[8]   Electroanalysis of dopamine at a gold electrode modified with N-acetylcysteine self-assembled monolayer [J].
Liu, T ;
Li, MX ;
Li, QY .
TALANTA, 2004, 63 (04) :1053-1059
[10]   Simultaneous voltammetric determination of dopamine and serotonin on carbon paste electrodes modified with iron(II) phthalocyanine complexes [J].
Oni, J ;
Nyokong, T .
ANALYTICA CHIMICA ACTA, 2001, 434 (01) :9-21