摘要
Prompt and accurate location of faults in a large-scale transmission system can accelerate system restoration, reduce outage time, and improve system reliability. Traditional approaches are categorized into traveling-wave-based and impedance-based measurement techniques. The traveling-wave-based approach requires detection devices to connect to the high-voltage transmission line, making the solution complex and costly. And the impedance-measurement-based approach is highly dependent on the quality of the signal and affected by fault resistance, ground resistance and non-homogeneity in line configuration. Hence, these approaches may cause a location error that is unacceptable in certain operation cases. In this paper, a novel approach based on noncontact magnetic-field measurement is proposed. With the magnetic field measured along the transmission line by using highly sensitive, broadband, and a low-cost magnetoresistive magnetic sensor, the fault span can be located. The collected data can be further used for identifying the fault type and location within the fault span. The overall system was designed and numerical simulations were performed on typical tower configurations. The simulated results verify the validity of the proposed scheme.
引用
收藏
页码:1186 / 1195
页数:10
相关论文
共 50 条
  • [41] A survey of fault location on transmission line based on synchronized phasor measurement technique
    Wang, Bo
    Wang, Wei
    Chen, Chao
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2009, 37 (13): : 122 - 128
  • [42] Fault location for overhead and cable hybrid transmission line in VSC-HVDC systems based on EMTR
    Zhang Y.
    Li T.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2024, 44 (03): : 180 - 186and224
  • [44] Online Measurement System for Fault Location in Railways Overhead Lines
    Peretto, L.
    Tinarelli, R.
    Margheri, L.
    Delucca, P.
    Palmucci, L.
    Spadini, A.
    2013 IEEE INTERNATIONAL WORKSHOP ON APPLIED MEASUREMENTS FOR POWER SYSTEMS (AMPS), 2013, : 51 - 56
  • [45] MAGNETIC-FIELD LINE RECONNECTION
    KADOMTSEV, BB
    USPEKHI FIZICHESKIKH NAUK, 1987, 151 (01): : 3 - 29
  • [46] MAGNETIC-FIELD LINE RECONNECTION
    KADOMTSEV, BB
    REPORTS ON PROGRESS IN PHYSICS, 1987, 50 (02) : 115 - 143
  • [47] MEASUREMENT OF SENSITIVITY OF TRANSMISSION ELECTRON-MICROSCOPES TO AC MAGNETIC-FIELD
    GEMPERLE, A
    GEMPERLOVA, J
    OPTIK, 1979, 53 (05): : 367 - 380
  • [48] MAGNETIC-FIELD INDUCTION FROM OVERHEAD TRANSMISSION AND DISTRIBUTION POWER-LINES ON PARALLEL FENCES
    JAFFA, KC
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (04): : 1624 - 1636
  • [49] Synchronised/unsynchronised measurements based novel fault location algorithm for transmission line
    Hinge, Trupti
    Dambhare, Sanjay
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (07) : 1493 - 1500
  • [50] A novel theory of fault location for EHV transmission line based on balance of energy
    Xin, ZT
    Yin, XG
    Zhang, Z
    Yang, JC
    UPEC 2004: 39th International Universitities Power Engineering Conference, Vols 1-3, Conference Proceedings, 2005, : 713 - 716