Comparison of macrobend seismic optical fiber accelerometer and ferrule-top cantilever fiber sensor for vibration monitoring

被引:1
作者
Poczesny, Tomasz [1 ]
Prokopczuk, Krzysztof [1 ]
Domanski, Andrzej W. [1 ]
机构
[1] Warsaw Univ Technol, Fac Phys, PL-00662 Warsaw, Poland
来源
OPTICAL SENSING AND DETECTION II | 2012年 / 8439卷
关键词
vibration monitoring; inertial sensor; bend loss; optical fiber loop; ferrule-top; optical fiber sensor; macrobend;
D O I
10.1117/12.928306
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper presents the exemplary application and comparison of a macrobend seismic optical fiber accelerometer and ferrule-top cantilever fiber sensor for long distance vibration monitoring with use of typical telecommunication optical transmission systems including optical fibers, transmitters and receivers. Use of telecommunication optical systems allows developing cost-effective monitoring and sensing architecture. All-optical fiber sensors do not create any fire hazard due to transmitting low power light through the optical fibers and lack of electrically driven parts in sensing part. Optical fiber macrobend seismic sensor consists of single mode optical fiber bended into a loop of radius around few millimeters with attached small seismic mass around 0.3 grams. We achieve signal that is proportional to the geometrical deformation of the loop. The ferrule-top cantilever (made by Optics11 - Amsterdam, Netherlands) optical fiber sensor is fabricated on a rectangular 3 mm x 3mm x 7 mm glass ferrule equipped with a central borehole and laser curved cantilever with dimensions of 200 microns wide, 30 microns thick and around 3 mm long. Construction allows measuring bending of the cantilever. Both optical fiber sensors in this setup measure force and acceleration similar to the piezoelectric accelerometers. The advantage of these devices is insensitivity to electromagnetic interference because of all-optical sensor head. We compared parameters and measurement capabilities of both sensor types.
引用
收藏
页数:8
相关论文
共 10 条
[1]   Ferrule-top cantilever optical fiber sensor for velocity measurements of low speed air flows [J].
Cipullo, A. ;
Gruca, G. ;
Heeck, K. ;
De Filippis, F. ;
Iannuzzi, D. ;
Zeni, L. .
21ST INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, 2011, 7753
[2]   Carving fiber-top optomechanical transducers from an optical fiber [J].
Deladi, S ;
Iannuzzi, D ;
Gadgil, VJ ;
Schreuders, H ;
Elwenspoek, MC .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2006, 16 (05) :886-889
[3]  
Domanski A.W., 2010, PHOTONICS LETT POLAN, V2, P58
[4]   CURVATURE LOSS FORMULA FOR OPTICAL FIBERS [J].
MARCUSE, D .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1976, 66 (03) :216-220
[5]  
Morawski R. Z., 2010, J PHYS C SERIES, V238, DOI [10.1088/1742-6596/238/1/012022, DOI 10.1088/1742-6596/1/012022]
[6]   Vibration sensor based on optical fiber loop with seismic mass [J].
Poczesny, T. ;
Prokopczuk, K. ;
Domanski, A. W. .
OPTICAL FIBERS AND THEIR APPLICATIONS 2011, 2011, 8010
[7]   Optical fiber macro-bend seismic sensor for real-time vibration monitoring in harsh industrial environment [J].
Poczesny, T. ;
Prokopczuk, K. ;
Makowski, P. L. ;
Domanski, A. W. .
OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION VII, 2011, 8082
[8]   Multi-point vibration sensor using a fiber optic telecommunication cable [J].
Prokopczuk, K. ;
Poczesny, T. ;
Domanski, A. W. .
OPTICAL FIBERS AND THEIR APPLICATIONS 2011, 2011, 8010
[9]   Improved bend loss formula verified for optical fiber by simulation and experiment [J].
Schermer, Ross T. ;
Cole, James H. .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 2007, 43 (9-10) :899-909
[10]  
WOLINSKI TR, 2007, P SOC PHOTO-OPT INS, V6585