Sensitivity and specificity of SWI venography for detection of cerebral venous alterations in multiple sclerosis

被引:9
作者
Beggs, Clive B. [1 ]
Shepherd, Simon J.
Dwyer, Michael G. [2 ]
Polak, Paul [2 ]
Magnano, Christopher [2 ]
Carl, Ellen [2 ]
Poloni, Guy U. [2 ]
Weinstock-Guttman, Bianca [3 ]
Zivadinov, Robert [2 ,3 ]
机构
[1] Univ Bradford, Ctr Infect Control & Biophys, Sch Engn Design & Technol, Bradford BD7 1DP, W Yorkshire, England
[2] SUNY Buffalo, Buffalo Neuroimaging Anal Ctr, Buffalo, NY 14260 USA
[3] SUNY Buffalo, Jacobs Neurol Inst, Buffalo, NY 14260 USA
关键词
Multiple sclerosis; Susceptibility-weighted imaging venography; Venous vasculature visibility; Diagnosis; Brain atrophy; WHITE-MATTER; BRAIN; LESIONS; VASCULATURE; IMPAIRMENT; VISIBILITY; PHASE;
D O I
10.1179/1743132812Y.0000000048
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objectives: To determine the sensitivity and specificity of decreased venous vasculature visibility (VVV) on susceptibility-weighted imaging (SWI) venography in multiple sclerosis (MS) patients versus controls, and to compare this with assessment of whole brain atrophy. Methods: Forty MS patients and 22 controls without known central nervous system (CNS) disease who had non-specific white-matter (WM) lesions were imaged on a 3T GE scanner using SWI venography. Apparent total venous volume (ATVV) and increased average distance from vein (DFV) were calculated for various vein mean diameter categories: <0.3, 0.3-0.6, 0.6-0.9, and >0.9 mm. Principal component analysis (PCA) was used to identify potential discriminatory metrics. Receiver operating characteristics (ROC) of these metrics, along with normalized brain volume (NBV), were calculated to determine sensitivity and specificity values between the groups. The efficacy of the metrics was validated against blinded data from 14 MS patients and 8 controls who had non-specific WM lesions. Results: PCA identified 0.3-0.6 mm venous relative fraction (VRF) and DFV as useful metrics. ROC analysis results in initial sample of 40 MS patients and 22 controls were (sensitivity, specificity): 0.3-0.6 mm VRF (95.0%, 100.0%); DFV (100.0%, 100.0%); and NBV (82.5%, 68.2%). The results in validation sample were: 0.3-0.6 mm VRF (92.9%, 75.0%); DFV (100.0%, 100.0%); and NBV (78.6%, 75.0%). Discussion: Altered VVV indices on SWI venography showed high sensitivity and specificity for MS. The value of SWI venography for diagnosis of MS has to be further tested at early disease stages and against patients with other neurologic diseases.
引用
收藏
页码:793 / 801
页数:9
相关论文
共 24 条
  • [1] PERIVENTRICULAR LESIONS IN MULTIPLE-SCLEROSIS - THEIR PERIVENOUS ORIGIN AND RELATIONSHIP TO ANTIGRANULOCYTES EPENDYMITIS
    ADAMS, CWM
    ABDULLA, YH
    TORRES, EM
    POSTON, RN
    [J]. NEUROPATHOLOGY AND APPLIED NEUROBIOLOGY, 1987, 13 (02) : 141 - 152
  • [2] PERIVASCULAR IRON DEPOSITION AND OTHER VASCULAR DAMAGE IN MULTIPLE-SCLEROSIS
    ADAMS, CWM
    [J]. JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1988, 51 (02) : 260 - 265
  • [3] Cardillo G., 2008, Roc curve: compute a receiver operating characteristics curve
  • [4] Vascular aspects of multiple sclerosis
    D'haeseleer, Miguel
    Cambron, Melissa
    Vanopdenbosch, Ludo
    De Keyser, Jacques
    [J]. LANCET NEUROLOGY, 2011, 10 (07) : 657 - 666
  • [5] Hypoperfusion of the cerebral white matter in multiple sclerosis: possible mechanisms and pathophysiological significance
    De Keyser, Jacques
    Steen, Christel
    Mostert, Jop P.
    Koch, Marcus W.
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2008, 28 (10) : 1645 - 1651
  • [6] FOG T, 1963, ACTA NEUROL SCAND, V39, P258
  • [7] Ge YL, 2005, AM J NEURORADIOL, V26, P2316
  • [8] Ge YL, 2005, AM J NEURORADIOL, V26, P1539
  • [9] Diminished Visibility of Cerebral Venous Vasculature in Multiple Sclerosis by Susceptibility-Weighted Imaging at 3.0 Tesla
    Ge, Yulin
    Zohrabian, Vahe M.
    Osa, Etin-Osa
    Xu, Jian
    Jaggi, Hina
    Herbert, Joseph
    Haacke, E. Mark
    Grossman, Robert I.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (05) : 1190 - 1194
  • [10] Susceptibility weighted imaging (SWI)
    Haacke, EM
    Xu, YB
    Cheng, YCN
    Reichenbach, JR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (03) : 612 - 618