Transesophageal Echocardiography Guided Patent Ductus Arteriosus Occlusion with a Duct Occluder

被引:23
作者
Silva, J. [1 ]
Domenech, O. [2 ]
Mavropoulou, A. [1 ]
Oliveira, P. [3 ]
Locatelli, C. [4 ]
Bussadori, C. [1 ]
机构
[1] Clin Vet Gran Sasso, Dept Cardiol, I-20131 Milan, Italy
[2] Ist Vet Novara, Granozzo Con Monticello, Italy
[3] Davies Vet Specialists, Higham Gobion, England
[4] Univ Milan, Fac Med Vet, Dipartimento Sci Vet & Sanita Pubbl, Milan, Italy
关键词
Canine; Congenital heart disease; Fluoroscopy; Interventional; DOGS; CATHETERIZATION;
D O I
10.1111/jvim.12201
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
BackgroundAngiography and fluoroscopy are the standard methods to guide transcatheter occlusion of patent ductus arteriosus (PDA). The use of iodinated contrast agents and radiation exposure pose risks of animals and staff. ObjectivesTo assess feasibility of transesophageal echocardiography (TEE) for device size selection and procedure monitoring for PDA occlusion with a duct occluder (DO) without the use of angiography. AnimalsEighty client-owned dogs with left-to-right PDA. MethodsProspective study. Dogs with left-to-right PDA undergoing transcatheter occlusion were included. Procedures were performed without angiography and device size selection was based on TEE measurements. Procedures were monitored with simultaneous TEE and fluoroscopy and both methods were compared. Visualization of the ductus and dimensions obtained by TEE and transthoracic echocardiography (TTE) were compared. ResultsComplete PDA occlusion was achieved in 79/80 cases. TEE was consistently superior to TTE for PDA visualization and the latter showed higher values for ductal dimensions when compared to the former. TEE provided adequate procedure monitoring in 73 cases (91%). Fluoroscopy exposure time (2.771.2minutes (mean, SD)) was lower than previously reported for the same procedure. Conclusions and Clinical ImportanceTEE is a useful and efficient tool for device size selection and can be used for procedure monitoring in most cases. Fluoroscopy exposure time can be reduced and the use of contrast agents can be avoided. However, fluoroscopy is required in a minority of cases when TEE monitoring is not feasible or incomplete and should be available for this procedure.
引用
收藏
页码:1463 / 1470
页数:8
相关论文
共 19 条
  • [1] Transarterial Ductal Occlusion with the Amplatzer Vascular Plug in 31 Dogs
    Achen, S. E.
    Miller, M. W.
    Gordon, S. G.
    Saunders, A. B.
    Roland, R. M.
    Drourr, L. T.
    [J]. JOURNAL OF VETERINARY INTERNAL MEDICINE, 2008, 22 (06) : 1348 - 1352
  • [2] Transthoracic echocardiographically-guided interventional cardiac procedures in the dog
    Caivano, Domenico
    Birettoni, Francesco
    Fruganti, Alessandro
    Rishniw, Mark
    Knafelz, Patrizia
    Moise, N. Sydney
    Porciello, Francesco
    [J]. JOURNAL OF VETERINARY CARDIOLOGY, 2012, 14 (03) : 431 - 444
  • [3] Transthoracic echocardiographic guidance of patent ductus arteriosus occlusion with an Amplatz® Canine Duct Occluder
    Falcini, R.
    Gaspari, M.
    Polveroni, G.
    [J]. RESEARCH IN VETERINARY SCIENCE, 2011, 90 (03) : 359 - 362
  • [4] Gordon Sonya G, 2010, J Vet Cardiol, V12, P85, DOI 10.1016/j.jvc.2010.04.004
  • [5] The use of transesophageal echocardiography monitoring of transcatheter closure of a persistent ductus arteriosus
    Lam, J
    Tanke, RB
    van Oort, A
    Helbing, WR
    Ottenkamp, J
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2001, 18 (03): : 197 - 202
  • [6] Meijer M, 2012, TIJDSCHR DIERGENEESK, V137, P376
  • [7] Miller Matthew W, 2006, J Vet Cardiol, V8, P109, DOI 10.1016/j.jvc.2006.07.001
  • [8] Minimally invasive per-catheter patent ductus arteriosus occlusion in dogs using a prototype duct occluder
    Nguyenba, T. P.
    Tobias, A. H.
    [J]. JOURNAL OF VETERINARY INTERNAL MEDICINE, 2008, 22 (01): : 129 - 134
  • [9] Nguyenba Thaibinh P, 2007, J Vet Cardiol, V9, P109, DOI 10.1016/j.jvc.2007.09.002
  • [10] Pariaut Romain, 2004, J Vet Cardiol, V6, P32, DOI 10.1016/S1760-2734(06)70062-5