Air injection methods: The key to a better performance of airlift pumps

被引:41
作者
Ahmed, W. H. [1 ]
Aman, A. M. [2 ]
Badr, H. M. [2 ]
Al-Qutub, A. M. [2 ]
机构
[1] Univ Guelph, Sch Engn, Guelph, ON N1G 2W1, Canada
[2] King Fahd Univ Petr & Minerals, Dept Mech Engn, Dhahran 31261, Saudi Arabia
关键词
Airlift pumps; Two-phase flow; Multi-injection; Dual-injection; Swirl; Pulsating; LIFT PUMP; FLOW; MODEL;
D O I
10.1016/j.expthermflusci.2015.09.022
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents a comprehensive experimental investigation on the effect of air injection methods on the performance of airlift pumps. The effect of air water two-phase flow patterns and the phase interaction is presented. The present airlift pump utilizes various air injectors specially designed to enable air injection radially, axially, dual (radial and axial), or with a swirl effect at the air inlet ports. In addition, two air injection modes including steadily and pulsating, at different injection frequencies, are investigated at different two-phase flow patterns. The results have shown that the performance of airlift pumps does not only depend on the design of air injector, but also on the dynamics of air injection method. The pulsating mode of air injection is found to control the intermittent flow pattern in the pump riser and consequently able to keep the pump operating within the best efficiency range. The maximum efficiency of the pulsating axial injection operating at a frequency of 1 Hz has improved by 60% over that of typical steady axial injection and by 24% over that of steady dual injection. Furthermore, the performance of airlift pumps with dual injector is improved by synchronizing the injected air at both axial and radial injection ports. The improvement in this arrangement is attributed to the better utilization of available compressed air, reduction of axial air penetration and minimization of water reverse flow in the riser pipe. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:354 / 365
页数:12
相关论文
共 31 条
[1]   Dual-Injection Airlift Pumps: An Enhanced Performance [J].
Ahmed, Wael H. ;
Badr, Hassan M. .
PARTICULATE SCIENCE AND TECHNOLOGY, 2012, 30 (06) :497-516
[2]  
CASTRO WE, 1975, WORLD MARI CULTURE S, V6, P451
[3]   A slug-churn flow model for small-diameter airlift pumps [J].
deCachard, F ;
Delhaye, JM .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1996, 22 (04) :627-649
[4]   Experimental study on the performance of an air-lift pump for artificial upwelling [J].
Fan, Wei ;
Chen, Jiawang ;
Pan, Yiwen ;
Huang, Haocai ;
Chen, Chen-Tung Arthur ;
Chen, Ying .
OCEAN ENGINEERING, 2013, 59 :47-57
[5]  
Haaland S., 1983, J FLUIDS ENG, V103, P89
[6]  
Hanafizadeh P., 2012, Multiphase Science and Technology, V24, P323
[7]   Effect of Step Geometry on the Performance of the Airlift Pump [J].
Hanafizadeh, P. ;
Karimi, A. ;
Saidi, M. H. .
INTERNATIONAL JOURNAL OF FLUID MECHANICS RESEARCH, 2011, 38 (05) :387-408
[8]   Effect of Bubble Size and Angle of Tapering Upriser Pipe on the Performance of Airlift Pumps [J].
Hanafizadeh, P. ;
Saidi, M. H. ;
Karimi, A. ;
Zamiri, A. .
PARTICULATE SCIENCE AND TECHNOLOGY, 2010, 28 (04) :332-347
[9]   Experimental investigation of characteristic curve for gas-lift pump [J].
Hanafizadeh, Pedram ;
Raffiee, Amir Hossein ;
Saidi, Mohammad Hassan .
JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2014, 116 :19-27
[10]   Visual technique for detection of gas-liquid two-phase flow regime in the airlift pump [J].
Hanafizadeh, Pedram ;
Ghanbarzadeh, Soheil ;
Saidi, Mohammad Hassan .
JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2011, 75 (3-4) :327-335