Nonlinear characterization of materials using the D4σ method inside a Z-scan 4f-system

被引:43
作者
Boudebs, Georges [1 ]
Besse, Valentin [1 ]
Cassagne, Christophe [1 ]
Leblond, Herve [1 ]
de Araujo, Cid B. [2 ]
机构
[1] Univ Angers, LUNAM Univ, Lab Photon Angers, LPhiA,EA 4464, F-49045 Angers 01, France
[2] Univ Fed Pernambuco, Dept Fis, BR-50670901 Recife, PE, Brazil
关键词
COHERENT IMAGING-SYSTEM; BEAM;
D O I
10.1364/OL.38.002206
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We show that direct measurement of the beam radius in Z-scan experiments using a CCD camera at the output of a 4f-imaging system allows higher sensitivity and better accuracy than Baryscan. One of the advantages is to be insensitive to pointing instability of pulsed lasers because no hard (physical) aperture is employed as in the usual Z-scan. In addition, the numerical calculations involved here and the measurement of the beam radius are simplified since we do not measure the transmittance through an aperture and it is not subject to mathematical artifacts related to a normalization process, especially when the diffracted light intensity is very low. (C) 2013 Optical Society of America
引用
收藏
页码:2206 / 2208
页数:3
相关论文
共 9 条
[1]   Third-order susceptibility measurements by nonlinear image processing [J].
Boudebs, G ;
Chis, M ;
Bourdin, JP .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1996, 13 (07) :1450-1456
[2]   Experimental techniques using 4f coherent imaging system for measuring nonlinear refraction [J].
Fedus, K. ;
Boudebs, G. .
OPTICS COMMUNICATIONS, 2013, 292 :140-148
[3]   Sensitivity of the 4f coherent imaging system used in degenerate multiwave mixing experiments [J].
Fedus, Kamil ;
Boudebs, Georges .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2009, 26 (02) :244-248
[4]   Dual-arm Z-scan technique to extract dilute solute nonlinearities from solution measurements [J].
Ferdinandus, Manuel R. ;
Reichert, Matthew ;
Ensley, Trenton R. ;
Hu, Honghua ;
Fishman, Dmitry A. ;
Webster, Scott ;
Hagan, David J. ;
Van Stryland, Eric W. .
OPTICAL MATERIALS EXPRESS, 2012, 2 (12) :1776-1790
[5]   Baryscan: a sensitive and user-friendly alternative to Z scan for weak nonlinearities measurements [J].
Godin, Thomas ;
Fromager, Michael ;
Cagniot, Emmanuel ;
Moncorge, Richard ;
Ait-Ameur, Kamel .
OPTICS LETTERS, 2011, 36 (08) :1401-1403
[6]  
International Organization for Standardization, 2005, 11146 ISO
[7]   SENSITIVE MEASUREMENT OF OPTICAL NONLINEARITIES USING A SINGLE BEAM [J].
SHEIKBAHAE, M ;
SAID, AA ;
WEI, TH ;
HAGAN, DJ ;
VANSTRYLAND, EW .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1990, 26 (04) :760-769
[8]   Z-scan technique through beam radius measurements [J].
Tsigaridas, G ;
Fakis, M ;
Polyzos, I ;
Persephonis, P ;
Giannetas, V .
APPLIED PHYSICS B-LASERS AND OPTICS, 2003, 76 (01) :83-86
[9]   ECLIPSING Z-SCAN MEASUREMENT OF LAMBDA/10(4) WAVE-FRONT DISTORTION [J].
XIA, T ;
HAGAN, DJ ;
SHEIKBAHAE, M ;
VANSTRYLAND, EW .
OPTICS LETTERS, 1994, 19 (05) :317-319