Structural characteristics of the pedicle and its role in screw stability

被引:353
作者
Hirano, T
Hasegawa, K
Takahashi, HE
Uchiyama, S
Hara, T
Washio, T
Sugiura, T
Yokaichiya, M
Ikeda, M
机构
[1] NIIGATA UNIV,SCH MED,DEPT ORTHOPAED SURG,NIIGATA,JAPAN
[2] NIIGATA UNIV,DEPT MECH ENGN,NIIGATA,JAPAN
关键词
bone mineral density; mechanical strength; pedicle; pedicle screw; structural characteristics;
D O I
10.1097/00007632-199711010-00007
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Cross-sectional regional bone mineral density of the pedicle was measured by peripheral quantitative computed tomography. Biomechanical tests were performed to clarify the role of the pedicle in screw stability. Objectives. to identify the structural characteristics of the pedicle that supports pedicle screw stability and the difference sin these characteristics between normal and osteoporotic vertebrae. Summary of Background Data. The pedicle screw is an essential component of many systems used to align the spine. The contribution of the pedicle to screw stability, however, has not been fully investigated. Methods. Trabecular, subcortical, and cortical bone mineral density and the area of the pedicle were measured by peripheral quantitative computed tomography. bone mineral density also was recalculated in four circumferential layers. These parameters were compared between normal and osteoporotic individuals. The relative contribution of the pedicle to screw stability was evaluated by caudocephalad and pull-out loading in a vertebra with or without its body. Results. Inner trabecular, middle subcortical, and outer cortical bone mineral density and cortical bone area in the pedicle were significantly lower in osteoporotic vertebrae than those in normal vertebrae. In the pedicle, bone mineral density increased close to the outer layer. Bone mineral density not as thick even in the outer layer in osteoporotic subjects. Approximately 80% of the caudocephalad stiffness and 60% of the pull-out strength of the pedicle screw depended on the pedicle rather than on the vertebral body. Conclusions. Screw stability depends on the structural characteristics of the pedicle. The pedicle was denser in the subcortical bone, in which the threads of the screw engage, than in trabecular bone. In osteoporosis, bone mineral density was not as dense even in the outer layer, and the cortex was thinner than normal. A larger screw would not enhance screw stability and may break the thin cortex in osteoporotic vertebrae.
引用
收藏
页码:2504 / 2509
页数:6
相关论文
共 27 条
[1]  
BANNA CJ, 1989, ORTHOPEDICS, V12, P939
[2]   THE EFFECTS OF PEDICLE SCREW FIT - AN IN-VITRO STUDY [J].
BRANTLEY, AGU ;
MAYFIELD, JK ;
KOENEMAN, JB ;
CLARK, KR .
SPINE, 1994, 19 (15) :1752-1758
[3]   INFLUENCE OF BONE-MINERAL DENSITY ON THE FIXATION OF THORACOLUMBAR IMPLANTS - A COMPARATIVE-STUDY OF TRANSPEDICULAR SCREWS, LAMINAR HOOKS, AND SPINOUS PROCESS WIRES [J].
COE, JD ;
WARDEN, KE ;
HERZIG, MA ;
MCAFEE, PC .
SPINE, 1990, 15 (09) :902-907
[4]   EFFECTS OF BONE-MINERAL DENSITY ON PEDICLE SCREW FIXATION [J].
HALVORSON, TL ;
KELLEY, LA ;
THOMAS, KA ;
WHITECLOUD, TS ;
COOK, SD .
SPINE, 1994, 19 (21) :2415-2420
[5]   An experimental study of a combination method using a pedicle screw and laminar hook for the osteoporotic spine [J].
Hasegawa, K ;
Takahashi, HE ;
Uchiyama, S ;
Hirano, T ;
Hara, T ;
Washio, T ;
Sugiura, T ;
Youkaichiya, M ;
Ikeda, M .
SPINE, 1997, 22 (09) :958-962
[6]   Internal architecture of the thoracic pedicle - An anatomic study [J].
Kothe, R ;
OHolleran, JD ;
Liu, W ;
Panjabi, MM .
SPINE, 1996, 21 (03) :264-270
[7]   MORPHOMETRY OF THE THORACIC AND LUMBAR SPINE RELATED TO TRANSPEDICULAR SCREW PLACEMENT FOR SURGICAL SPINAL FIXATION [J].
KRAG, MH ;
WEAVER, DL ;
BEYNNON, BD ;
HAUGH, LD .
SPINE, 1988, 13 (01) :27-32
[8]  
KRAG MH, 1986, CLIN ORTHOP RELAT R, V203, P75
[9]   Cortical thickness assessed by peripheral quantitative computed tomography: Accuracy evaluated on radius specimens [J].
Louis, O ;
Willnecker, J ;
Soykens, S ;
VandenWinkel, P ;
Osteaux, M .
OSTEOPOROSIS INTERNATIONAL, 1995, 5 (06) :446-449
[10]   CORTICAL MINERAL-CONTENT OF THE RADIUS ASSESSED BY PERIPHERAL QCT PREDICTS COMPRESSIVE STRENGTH ON BIOMECHANICAL TESTING [J].
LOUIS, O ;
BOULPAEP, F ;
WILLNECKER, J ;
VANDENWINKEL, P ;
OSTEAUX, M .
BONE, 1995, 16 (03) :375-379