Proposal and optimization of method for direct determination of the thoron progeny concentrations and thoron equilibrium

被引:4
|
作者
Forkapic, Sofija [1 ]
Lakatos, Robert [2 ]
Celikovic, Igor [3 ]
Bikit-Schroeder, Kristina [1 ]
Mrdja, Dusan [1 ]
Radolic, Vanja [4 ]
Samardzic, Selena [2 ]
机构
[1] Univ Novi Sad, Fac Sci, Dept Phys, Trg Dositeja Obradovica 3, Novi Sad, Serbia
[2] Univ Novi Sad, Fac Tech Sci, Trg Dositeja Obradovica 6, Novi Sad, Serbia
[3] Univ Belgrade, Vinca Inst Nucl Sci, Lab Nucl & Plasma Phys, Belgrade, Serbia
[4] JJ Strossmayer Univ Osijek, Dept Phys, Trg Lj Gaja 6, Osijek, Croatia
关键词
Thoron; Thoron progeny; Equilibrium equivalent thoron concentration; INDOOR RADON; DWELLINGS; RN-220;
D O I
10.1016/j.radphyschem.2019.02.043
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Most studies focused on thoron have shown that indoor thoron originates mainly from building materials and that thoron concentrations exponentially decrease with a distance from a wall surface. On the contrary, due to longer half-lives of thoron progenies, Pb-212 and Bi-212, which are mainly responsible for the bronchial dose, it is expected that their spatial distribution is homogeneous. Therefore, direct measurements of thoron progeny concentrations or direct thoron measurement and determination of thoron equilibrium factor are necessary for accurate dose assessment. In this paper, we have optimized and validated a reliable and inexpensive method for direct measurement of thoron progenies concentrations based on an air filtration followed by gamma spectrometry measurements. With simultaneous measurements of indoor thoron by the RAD7 active device, the equilibrium factor for thoron in 15 different investigated dwellings was estimated. Obtained results for the equilibrium equivalent thoron concentrations in the range from 0.277 Bq/m(3) to 11.34 Bq/m(3) and thoron equilibrium factor in the range from 0.0047 to 0.098 with arithmetic mean value of 0.034 are in good agreement with already published results.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 29 条
  • [1] Simulation of thoron and thoron progeny concentrations in the indoor environment
    de With, Govert
    de Jong, Peter
    JOURNAL OF BUILDING PHYSICS, 2011, 35 (02) : 101 - 127
  • [2] Convenient methods for evaluation of indoor thoron progeny concentrations
    Zhuo, WH
    Tokonami, S
    HIGH LEVELS OF NATURAL RADIATION AND RADON AREAS: RADIATION DOSE AND HEALTH EFFECTS, 2005, 1276 : 219 - 220
  • [3] Optimization of the thoron progeny compensation system of a thoron calibration chamber
    Weiwei Li
    Qingzhi Zhou
    Zhengzhong He
    Guiyuan Li
    Wei Liu
    Journal of Radioanalytical and Nuclear Chemistry, 2020, 324 : 1255 - 1263
  • [4] Optimization of the thoron progeny compensation system of a thoron calibration chamber
    Li, Weiwei
    Zhou, Qingzhi
    He, Zhengzhong
    Li, Guiyuan
    Liu, Wei
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2020, 324 (03) : 1255 - 1263
  • [5] Response of direct thoron progeny sensors (DTPS) to various aerosol concentrations and ventilation rates
    Mishra, Rosaline
    Prajith, R.
    Sapra, B. K.
    Mayya, Y. S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (06) : 671 - 675
  • [6] Study of a deposition-based direct thoron progeny sensor (DTPS) technique for estimating equilibrium equivalent thoron concentration (EETC) in indoor environment
    Mishra, Rosaline
    Mayya, Y. S.
    RADIATION MEASUREMENTS, 2008, 43 (08) : 1408 - 1416
  • [7] SIMULTANEOUS MEASUREMENTS OF RADON, THORON, AND EQUILIBRIUM EQUIVALENT CONCENTRATIONS IN FAMILY HOUSE - SINGLE CASE STUDY
    Lakatos, Robert Z.
    Forkapic, Sofija M.
    Radolic, Vanja
    Celikovic, Igor T.
    Samardzic, Selena D.
    Mrdja, Dusan S.
    Bikit-Schroeder, Kristina I.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2019, 34 (02) : 181 - 188
  • [8] Direct measurement of indoor thoron and radon progeny and estimation of inhalation dose in three cities in Gabon: Comparison of the use of thoron typical and measured equilibrium factor values
    Mouandza, Sylvere Yannick Loemba
    Saidou
    Ndong, W.
    Kranrod, Chutima
    Hosoda, Masahiro
    Meye, P. Ondo
    Djeune, R. Bipolo
    Mombo, E. -D. Durastanti-Rabenga
    Andeme-Abondhoume, H. M. -J.
    Ndjembidouma, B. C. Mabika
    Ekogo, T. B.
    Ben-Bolie, G. H.
    Tokonami, Shinji
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2024, 280
  • [9] Effective dose estimation of radon, thoron and their progeny concentrations in the environs of Himalayan belt, India
    Semwal, P.
    Agarwal, T. K.
    Joshi, M.
    Kumar, A.
    Singh, K.
    Ramola, R. C.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2023, 20 (04) : 4127 - 4138
  • [10] DYNAMICS OF OUTDOOR RADON AND THORON PROGENY CONCENTRATIONS IN SOME GEOGRAPHICAL AREAS OF ROMANIA
    Simion, E.
    Mihalcea, I.
    Cuculeanu, V.
    Simion, F.
    ROMANIAN JOURNAL OF PHYSICS, 2013, 58 : S251 - S261