Detection of Bacillus Anthracis Spores in Water Using a Phage-coated Piezoelectric Membrane

被引:1
|
作者
Lu, X. [1 ,2 ]
Wang, L. [1 ]
Hou, L. [1 ]
Zhang, L. [2 ]
Chin, B. A. [2 ]
Cheng, Z-Y [2 ]
机构
[1] Xian Univ Technol, Sch Mat Sci & Engn, Lab Funct Films, Xian 710048, Peoples R China
[2] Auburn Univ, Mat Res & Educ Ctr, Auburn, AL 36849 USA
来源
基金
中国国家自然科学基金;
关键词
D O I
10.1149/08010.1541ecst
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Phage-coated piezoelectric membrane was introduced as biosensor platform for Bacillus Anthracis spores detection in water. The working principle of the membrane is based on resonant frequency shift due to the mass load of Bacillus Anthracis spores on the membrane surface from surrounding liquid. The resonant behaviors of membrane were characterized both in air and in water. And Bacillus Anthracis spores were demonstrated using a PVDF membrane in water.
引用
收藏
页码:1541 / 1547
页数:7
相关论文
共 50 条
  • [11] Rapid Detection of Bacillus anthracis Spores Using Immunomagnetic Separation and Amperometry
    Waller, David F.
    Hew, Brian E.
    Holdaway, Charlie
    Jen, Michael
    Peckham, Gabriel D.
    BIOSENSORS-BASEL, 2016, 6 (04):
  • [12] Microresonator mass sensors for detection of Bacillus anthracis Sterne spores in air and water
    Davila, Angelica P.
    Jang, Jaesung
    Gupta, Amit K.
    Walter, Tom
    Aronson, Arthur
    Bashir, Rashid
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (12): : 3028 - 3035
  • [13] Microresonator mass sensors for detection of Bacillus anthracis Sterne spores in air and water
    Davila, Angelica P.
    Jang, Jaesung
    Gupta, Amit K.
    Walter, Tom
    Aronson, Arthur
    Bashir, Rashid
    Biosensors and Bioelectronics, 2007, 22 (12) : 3028 - 3035
  • [14] Multiple Phage-Based Magnetoelastic Biosensors System for the Detection of Salmonella typhimurium and Bacillus anthracis spores
    Huang, S.
    Li, S.
    Yang, H.
    Johnson, M. L.
    Lakshmanan, R. S.
    Chen, I. -H.
    Petrenko, V. A.
    Barbaree, J. M.
    Chin, B. A.
    MATERIALS AND DEVICES FOR SMART SYSTEMS III, 2009, 1129 : 137 - +
  • [15] Characterization of phage-coupled magnetoelastic micro-particles for the detection of Bacillus anthracis Sterne spores
    Wan, Jiehui
    Johnson, Michael L.
    Horikawa, Shin
    Chin, Bryan A.
    Petrenko, Valery A.
    2007 IEEE SENSORS, VOLS 1-3, 2007, : 1085 - 1092
  • [16] Fast and Sensitive Detection of Bacillus anthracis Spores by Immunoassay
    Morel, Nathalie
    Volland, Herve
    Dano, Julie
    Lamourette, Patricia
    Sylvestre, Patricia
    Mock, Michele
    Creminon, Christophe
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2012, 78 (18) : 6491 - 6498
  • [17] Development of an amperometric biosensor for the detection of Bacillus anthracis spores
    Ortatatli, Mesut
    Saatci, Ebru
    Kilic, Zahir
    Kenar, Levent
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2024, 110 (03)
  • [18] ANYL 46-Phage-based array biosensor: Application for Bacillus anthracis spores detection and their quantification using fluorescence spectroscopy
    Ramanathan, Madhumati
    Sarsenova, Amur
    Chen, I-Hsuan
    Barbaree, J.
    Ramanculov, Erlan
    Simonian, Aleksandr L.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2008, 236
  • [19] Diagnostic probes for Bacillus anthracis spores selected from a landscape phage library
    Brigati, J
    Williams, DD
    Sorokulova, IB
    Nanduri, V
    Chen, IH
    Turnbough, CL
    Petrenko, VA
    CLINICAL CHEMISTRY, 2004, 50 (10) : 1899 - 1906
  • [20] DETECTION OF SPORES OF BACILLUS-ANTHRACIS USING THE POLYMERASE CHAIN-REACTION
    CARL, M
    HAWKINS, R
    COULSON, N
    LOWE, J
    ROBERTSON, DL
    NELSON, WM
    TITBALL, RW
    WOODY, JN
    JOURNAL OF INFECTIOUS DISEASES, 1992, 165 (06): : 1145 - 1148