Conversion of shoulder arthroplasty to reverse implants: clinical and radiological results using a modular system

被引:50
作者
Castagna, Alessandro [1 ]
Delcogliano, Marco [2 ]
de Caro, Francesca [3 ]
Ziveri, Giovanni [3 ]
Borroni, Mario [1 ]
Gumina, Stefano [4 ]
Postacchini, Franco [4 ]
De Biase, Carlo Felice [2 ]
机构
[1] Humanitas Clin Inst, Milan, Italy
[2] Univ Hosp Parma, Orthoped Div, I-43126 Parma, Italy
[3] Univ Hosp Parma, Orthoped Clin, I-43126 Parma, Italy
[4] Univ Roma La Sapienza, Hosp Umberto, I-00185 Rome, Italy
关键词
5-YEAR FOLLOW-UP; PROXIMAL HUMERUS; FAILED HEMIARTHROPLASTY; PROSTHETIC REPLACEMENT; GLENOHUMERAL ARTHRITIS; FRACTURES; REVISION; OUTCOMES; COMPLICATIONS; INSTABILITY;
D O I
10.1007/s00264-013-1907-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Revision of a shoulder arthroplasty to a reverse arthroplasty is a highly demanding procedure. The aim of this study is to report the clinical results of hemi and total shoulder prosthesis revisions to reverse implants without removal of the humeral stem, using a modular shoulder replacement system (SMR Lima LTD). We retrospectively reviewed 26 patients who underwent an operation from 2004 to 2009. The patients were divided into two groups: in Group I, 18 patients underwent a revision of hemiarthroplasty implanted for fracture; in Group II, eight patients underwent a revision of anatomical total prosthesis. All patients were evaluated at a mean follow-up of 32.3 (+/- 12.7) months using the Constant score rating scale and by range of motion evaluation, EQ-VAS, X-ray and CT scan. The Constant score of each patient was 47.88 (+/- 5.88) after the revision. The EQ-VAS improved from 40 (+/- 20) to 70 (+/- 10). All patients improved in terms of range of motion. The radiographs and CT scans obtained after revision showed good integration and no signs of loosening of the implant. The mean time of surgery was recorded as 62' (+/- 8'), with a maximum blood loss of less than 300 ml in all cases. Our study demonstrates that using a full modular system at the time of the first implant allows avoidance of the step to remove the humeral stem and metal back in cases of shoulder prosthesis revision to a reverse prosthesis, resulting in a short operative time, few intraoperative complications and a satisfactory clinical outcome at medium-term follow-up.
引用
收藏
页码:1297 / 1305
页数:9
相关论文
共 42 条
[1]   Complications in shoulder arthroplasty: an analysis of 485 cases [J].
Aldinger, Peter R. ;
Raiss, Patric ;
Rickert, Markus ;
Loew, Markus .
INTERNATIONAL ORTHOPAEDICS, 2010, 34 (04) :517-524
[2]   Are Shoulders with A Reverse Shoulder Prosthesis Strong Enough? A Pilot Study [J].
Alta, Tjarco D. W. ;
Veeger, H. E. J. ;
Janssen, Thomas W. J. ;
Willems, W. Jaap .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (08) :2185-2192
[3]   Shoulder hemiarthroplasty for acute fractures of the proximal humerus: A minimum five-year follow-up [J].
Antuna, Samuel A. ;
Sperling, John W. ;
Cofield, Robert H. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2008, 17 (02) :202-209
[4]   Tuberosity malposition and migration:: Reasons for poor outcomes after hemiarthroplasty for displaced fractures of the proximal humerus [J].
Boileau, P ;
Krishnan, SG ;
Tinsi, L ;
Walch, G ;
Coste, JS ;
Molé, D .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2002, 11 (05) :401-412
[5]   Shoulder arthroplasty for the treatment of the sequelae of fractures of the proximal humerus [J].
Boileau, P ;
Trojani, C ;
Walch, G ;
Krishnan, SG ;
Romeo, A ;
Sinnerton, R .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2001, 10 (04) :299-308
[6]   Conversion of painful hemiarthroplasty to total shoulder arthroplasty: Long-term results [J].
Carroll, RM ;
Izquierdo, R ;
Vazquez, M ;
Blaine, TA ;
Levine, WN ;
Bigliani, LU .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2004, 13 (06) :599-603
[7]  
COMPITO CA, 1994, CLIN ORTHOP RELAT R, P27
[8]   Prognostic factors in prosthetic replacement for acute proximal humerus fractures [J].
Demirhan, M ;
Kilicoglu, O ;
Altinel, L ;
Eralp, L ;
Akalin, Y .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2003, 17 (03) :181-188
[9]   Clinical results of revision shoulder arthroplasty for glenoid component loosening [J].
Deutsch, Allen ;
Abboud, Joseph A. ;
Kelly, James ;
Mody, Milan ;
Norris, Tom ;
Ramsey, Matthew L. ;
Iannotti, Joseph P. ;
Williams, Gerald R. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (06) :706-716
[10]   Outcomes analysis of revision total shoulder replacement [J].
Dines, Joshua S. ;
Fealy, Stephen ;
Strauss, Eric J. ;
Allen, Answorth ;
Craig, Edward V. ;
Warren, Russell E. ;
Dines, David M. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (07) :1494-1500