Measurement of vertebral body heights: Ex vivo comparisons between morphometric X-ray absorptiometry, morphometric radiography and direct measurements

被引:10
作者
Edmondston, SJ
Price, RI
Valente, B
Singer, KP
机构
[1] Curtin Univ Technol, Sch Physiotherapy, Shenton Pk, WA 6008, Australia
[2] Sir Charles Gairdner Hosp, Dept Med Technol & Phys, Perth, WA, Australia
[3] Royal Perth Hosp, Dept Diagnost Radiol, Perth, WA, Australia
关键词
morphometric X-ray absorptiometry; osteoporosis; vertebral fracture; vertebral morphometry;
D O I
10.1007/s001980050187
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Morphometric X-ray absorptiometry (MXA) offers some potential advantages over spinal radiography for the quantitative evaluation of vertebral fractures in individuals with spinal osteoporosis. This ex vivo study examined the accuracy of MXA and quantitative morphometry (QM) for the evaluation of vertebral height, in relation to direct measurements from cadaveric vertebral columns. Spinal radiographs and MXA scans were obtained from nine cadaveric vertebral columns (mean age at death 64 years). Anterior, middle and posterior vertebral body heights of all segments from T4 to LA were measured interactively using MXA software and QM (from the spinal radiographs), and compared with direct measurements derived using digital callipers following cadaveric dissection. Coefficients of variation for repeat QM and MXA scan analysis were less than 2%. The QM and MXA measurements were both strongly correlated (r(2) = 0.99) with the direct measurements, with accuracy errors of between 2.6% and 4.3%, and 4.5% and 4.8%, for QM and MXA respectively. At the three measurement sites, analysis of measurement differences showed that QM tended to overestimate the true height and MXA tended towards under-estimation. The mean difference between the direct measurements and QM measurements ranged from 2.7% to 8.7%, and the mean difference between direct and MXA measurements ranged from -2.9% to 4.1%. There was strong linear association between the MXA and QM measurements (r(2) = 0.99) with mean differences at the three measurement sites ranging from -4.1% to -5.9%. Under the optimal (ex vivo) scanning conditions used in this study, MXA is comparable to spinal radiography for the assessment of vertebral height. Further studies are required to determine the conditions under which satisfactory MXA image resolution and measurement accuracy can be achieved in a clinical population.
引用
收藏
页码:7 / 13
页数:7
相关论文
共 16 条
[1]   Vertebral morphometry studies using dual-energy x-ray absorptiometry [J].
Blake, GM ;
Rea, JA ;
Fogelman, I .
SEMINARS IN NUCLEAR MEDICINE, 1997, 27 (03) :276-290
[2]  
Chappard C, 1998, BRIT J RHEUMATOL, V37, P496
[3]  
CUMMINGS SR, 1995, J BONE MINER RES, V10, P518
[4]  
DRAPER NR, 1967, APPL REGRESSION ANAL
[5]   ACCURACY OF LATERAL DUAL-ENERGY X-RAY ABSORPTIOMETRY FOR THE DETERMINATION OF BONE-MINERAL CONTENT IN THE THORACIC AND LUMBAR SPINE - AN INVITRO STUDY [J].
EDMONDSTON, SJ ;
SINGER, KP ;
PRICE, RI ;
BREIDAHL, PD .
BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (784) :309-313
[6]   RECENT DEVELOPMENTS IN DXA - QUALITY OF NEW DXA/MXA-DEVICES FOR DENSITOMETRY AND MORPHOMETRY [J].
FELSENBERG, D ;
GOWIN, W ;
DIESSEL, E ;
ARMBRUST, S ;
MEWS, J .
EUROPEAN JOURNAL OF RADIOLOGY, 1995, 20 (03) :179-184
[7]  
Genant HK, 1996, J BONE MINER RES, V11, P984
[8]   THE BONE-MINERAL CONTENT AND ULTIMATE COMPRESSIVE STRENGTH OF LUMBAR VERTEBRAE [J].
HANSSON, T ;
ROOS, B ;
NACHEMSON, A .
SPINE, 1980, 5 (01) :46-55
[9]   AN ANALYSIS OF ERRORS IN KINEMATIC PARAMETERS ASSOCIATED WITH INVIVO FUNCTIONAL RADIOGRAPHS [J].
PANJABI, M ;
CHANG, D ;
DVORAK, J .
SPINE, 1992, 17 (02) :200-205
[10]   Optimizing data acquisition and analysis of morphometric x-ray absorptiometry [J].
Rea, JA ;
Steiger, P ;
Blake, GM ;
Fogelman, I .
OSTEOPOROSIS INTERNATIONAL, 1998, 8 (02) :177-183