Multi-sensor system with Bluetooth connectivity for non-invasive measurements of human body physical parameters

被引:31
作者
Depari, A. [1 ]
Flammini, A. [1 ]
Rinaldi, S. [1 ]
Vezzoli, A. [1 ]
机构
[1] Univ Brescia, Dept Informat Engn, I-25123 Brescia, Italy
关键词
Photoplethysmographic sensor; Tissue impedance measurement; Wireless sensor; Portable smart sensor; Non-invasive measurement;
D O I
10.1016/j.sna.2013.05.001
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the last few years, the availability of powerful personal computing devices, like smartphones, has opened new scenarios to the so called "Body Area Network" (BAN), i.e., sensor networks specifically designed to monitor physical conditions of the user. The traditional methods adopted to monitor physical parameters, like heart beat rate or exertion level, are not suitable for real-time measurements. However, a continuous monitoring of such kind of parameters would allow the athletes to constantly control their physical conditions, furnishing useful information to prevent overstrain and to improve their performance. In this work, a simple, portable and low-cost system for non-invasive and real-time measurement of physical parameters is proposed and experimentally characterized. It is composed of three units: the sensor apparatus, electronic interface circuit, and the data transmission unit. Two different sensors are combined in a unique structure to be placed in a clip-like fashion on the earlobe or other body part of a person. A photoplethysmographic sensor is used to optically measure the changes of blood volume in the arteries, thus to acquire information about heart beat, blood pressure, and arrhythmias. The second sensor is composed of two electrodes, hence an impedance measurement of the tissue is carried out. The impedance estimation can be used to monitor the dielectric properties of biological tissues and fluids, like blood flow. A commercial battery-operated Bluetooth earphone is used both to transmit sensor data and to provide the power supply for the sensors and the first conditioning electronics. Data transmission is operated by the standard Bluetooth Hands-Free profile; therefore, sensor data can be easily acquired, elaborated and visualized by a broad range of commercial devices. In fact, Hands-Free is the only Bluetooth data communication profile supported by any smartphone, from the low-cost ones to the high-end devices. The experimental characterization of the prototype, performed by using a specifically designed application for Android smartphone systems, has demonstrated the validity of the proposed approach. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:147 / 154
页数:8
相关论文
共 20 条
[1]  
[Anonymous], CORE SPECIFICATION V
[2]  
[Anonymous], P INSTR MEAS TECHN C
[3]  
[Anonymous], MED INSTRUMENTATION
[4]  
[Anonymous], TCZT8020 PAER DAT SH
[5]  
De Dominicis CM, 2012, 2012 IEEE SENSORS APPLICATIONS SYMPOSIUM (SAS 2012), P120
[6]   A portable multi-sensor system for non-invasive measurement of biometrical data [J].
Depari, A. ;
Flammini, A. ;
Rinaldi, S. ;
Vezzolia, A. .
26TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS, EUROSENSOR 2012, 2012, 47 :1323-1326
[7]   IEEE802.11 sensor networking [J].
Ferrari, P ;
Flammini, A ;
Marioli, D ;
Taroni, A .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2006, 55 (02) :615-619
[8]   A Bluetooth-based sensor network with Web interface [J].
Ferrari, P ;
Flammini, A ;
Marioli, D ;
Sisinni, E ;
Taroni, A .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2005, 54 (06) :2359-2363
[9]  
Flammini A., 2010, 2010 IEEE International Instrumentation & Measurement Technology Conference - I2MTC 2010, P1618, DOI 10.1109/IMTC.2010.5488040
[10]   Development of wearable intra-body communication devices [J].
Hachisuka, K ;
Nakata, A ;
Takeda, T ;
Shiba, K ;
Sasaki, K ;
Hosaka, H ;
Itao, K .
SENSORS AND ACTUATORS A-PHYSICAL, 2003, 105 (01) :109-115