Bidirectional Flow in the Vertebral Artery Is Not Always Indicative of the Subclavian Steal Phenomenon

被引:10
作者
Chen, Shun-Ping [1 ]
Hu, Yuan-Ping [1 ]
Fan, Liang-Hao [2 ]
Zhu, Xue-Lian [1 ]
机构
[1] Wenzhou Med Coll, Affiliated Hosp 1, Dept Ultrasonog, Wenzhou 325000, Zhejiang, Peoples R China
[2] Wenzhou Med Coll, Affiliated Hosp 1, Dept Intervent Radiol, Wenzhou 325000, Zhejiang, Peoples R China
关键词
angiography; bidirectional flow; occlusion; sonography; subclavian steal; vertebral artery; WAVE-FORM; ULTRASONOGRAPHY; HYPOPLASIA; STENOSIS; CIRCULATION; ULTRASOUND;
D O I
10.7863/ultra.32.11.1945
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective-To evaluate the causes of bidirectional flow in the vertebral artery detected by Doppler sonography and its differential diagnosis. Methods-Twenty-nine patients with bidirectional flow in the vertebral artery were retrospectively studied. The vertebral artery parameters, including peak antegrade velocity (PAV), peak reversed velocity (PRV), maximum peak velocity (MPV), peak systolic velocity, resistive index (RI), and diameter, were measured. The MPV was defined as the MPV of bidirectional flow regardless of the velocity of antegrade or retrograde flow. To better predict the cause of bidirectional flow, receiver operating characteristic curves were constructed for these parameters, and the best cutoff values were obtained. The cause of bidirectional flow was determined by angiography. Results-The causes of bidirectional flow were classified as the subclavian steal phenomenon (n = 21) and factors unrelated to the steal phenomenon (n = 8, including a hypoplastic vertebral artery [n = 4] and proximal vertebral artery stenosis and occlusion [n = 4]). Significant differences were observed between the steal phenomenon and non steal phenomenon groups (P < .05) for MPV, PRV, PAV, target vertebral artery diameter, and contralateral RI. To determine the cause of bidirectional flow, areas under the receiver operating characteristic curves for the different parameters were obtained: 0.929 for MPV, 0.881 for PRV, 0.824 for PAV, 0.753 for target vertebral artery diameter, and 0.845 for contralateral RI. The cutoff value for MPV was 26.1 cm/s, and the accuracy was 93% (27 of 29). Conclusions-Bidirectional flow in the vertebral artery is not always indicative of the subclavian steal phenomenon. Measurement of hemodynamic parameters in the vertebral artery, such as MPV, can facilitate determination of the cause of bidirectional flow.
引用
收藏
页码:1945 / 1950
页数:6
相关论文
共 20 条
[1]   Ultrasound of the extracranial vertebral artery [J].
Buckenham, TM ;
Wright, IA .
BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (913) :15-20
[2]   Estimation of the Youden index and its associated cutoff point [J].
Fluss, R ;
Faraggi, D ;
Reiser, B .
BIOMETRICAL JOURNAL, 2005, 47 (04) :458-472
[3]   Color Doppler Imaging Evaluation of Proximal Vertebral Artery Stenosis [J].
Hua, Yang ;
Meng, Xiu-Feng ;
Jia, Ling-Yun ;
Ling, Chen ;
Miao, Zhong-Rong ;
Ling, Feng ;
Liu, Ji-Bin .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (05) :1434-1438
[4]   Evaluation of vertebral artery hypoplasia and asymmetry by color-coded duplex ultrasonography [J].
Jeng, JS ;
Yip, PK .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (05) :605-609
[5]   Color-coded Doppler imaging of subclavian steal syndrome [J].
Kaneko, A ;
Ohno, R ;
Hattori, K ;
Furuya, D ;
Asano, Y ;
Yamamoto, T ;
Kim, H ;
Shimazu, K ;
Hamaguchi, K .
INTERNAL MEDICINE, 1998, 37 (03) :259-264
[6]   Noninvasive Detection of Vertebral Artery Stenosis A Comparison of Contrast-Enhanced MR Angiography, CT Angiography, and Ultrasound [J].
Khan, Sofia ;
Rich, Philip ;
Clifton, Andrew ;
Markus, Hugh S. .
STROKE, 2009, 40 (11) :3499-3503
[7]   Vertebral artery Doppler waveform changes indicating subclavian steal physiology [J].
Kliewer, MA ;
Hertzberg, BS ;
Kim, DH ;
Bowie, JD ;
Courneya, DL ;
Carroll, BA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (03) :815-819
[8]   Prevalence and Impact of the Subclavian Steal Syndrome [J].
Labropoulos, Nicos ;
Nandivada, Prathima ;
Bekelis, Kimon .
ANNALS OF SURGERY, 2010, 252 (01) :166-170
[9]   Role of vertebral artery hypoplasia in migraine [J].
Lovrencic-Huzjan, A ;
Demarin, V ;
Rundek, T ;
Vukovic, V .
CEPHALALGIA, 1998, 18 (10) :684-686
[10]   Supraaortic arteries: Contrast-enhanced MR angiography at 3.0T - Highly accelerated parallel acquisition for improved spatial resolution over an extended field of view [J].
Nael, Kambiz ;
Villablanca, J. Pablo ;
Pope, Whitney B. ;
McNamara, Thomas O. ;
Laub, Gerhard ;
Finn, J. Paul .
RADIOLOGY, 2007, 242 (02) :600-609