Hybrid dynamic coating with n-dodecyl β-D-maltoside and methyl cellulose for high-performance carbohydrate analysis on poly(methyl methacrylate) chips

被引:44
作者
Dang, FQ
Kakehi, K
Cheng, JJ
Tabata, O
Kurokawa, M
Nakajima, K
Ishikawa, M
Baba, Y
机构
[1] AIST, Hlth Technol Res Ctr, Nanobioanal Team, Takamatsu, Kagawa 7610395, Japan
[2] Kinki Univ, Fac Pharmaceut Sci, Higashi Osaka 5778502, Japan
[3] Netherlands Inst Brain Res, NL-1105 AZ Amsterdam, Netherlands
[4] Kyoto Univ, Grad Sch Engn, Dept Mech Engn, Sakyo Ku, Kyoto 6068501, Japan
[5] Starlite Co Ltd, Kusatsu 5203004, Japan
[6] Nagoya Univ, Grad Sch Engn, Dept Appl Chem, Chikusa Ku, Nagoya, Aichi 4648603, Japan
关键词
D O I
10.1021/ac051702f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hybrid dynamic coating using n-dodecyl beta-D-maltoside (DDM) and methyl cellulose (MC) has been developed for suppression of analyte adsorption and electroosmotic flow (EOF) in a poly(methyl methacrylate) (PMMA) channel. The adsorption of APTS-labeled sugars in a PMMA channel was obviously suppressed with DDM dynamic coating; however, EOF was reduced only by a factor of similar to 25%, resulting in irreproducible separations. In contrast, both analyte adsorption and EOF in a PMMA channel were efficiently minimized with MC coating; however, concentrated MC above 0.3% was required to achieve high-performance separations, which greatly increased viscosity of the solution and caused difficulties during buffer loading and rinsing. In addition, n-dodecyltrimethylammonium chloride did not show observable effects on reducing analyte adsorption, although it has the same hydrophobic alkyl chain as DDM. These results strongly indicated that the polysaccharide moiety of surface modifiers has a specific affinity to surface charges and is crucial to achieving efficient and stable dynamic coating on the PMMA surface. Hybrid dynamic coating with 0.25% DDM and 0.03% MC was found to minimize both analyte adsorption and EOF in a PMMA channel to a negligible level, while still keeping a low viscosity of the solution. High-speed and high-throughput profiling of the N-linked glycans derived from alpha 1-acid glycoprotein, fetuin, and ribonuclease B was demonstrated in both single-channel and 10-channel PMMA chips using DDM-MC hybrid coating. We propose that DDM-MC hybrid coating might be a general method for suppressing analyte adsorption and EOF in polymer MCE devices. The current MCE-based method might be a promising alternative for high-throughput screening of carbohydrate alterations in glycoproteins.
引用
收藏
页码:1452 / 1458
页数:7
相关论文
共 43 条
  • [1] Becker H, 2000, ELECTROPHORESIS, V21, P12, DOI 10.1002/(SICI)1522-2683(20000101)21:1<12::AID-ELPS12>3.3.CO
  • [2] 2-Z
  • [3] Surface modification in microchip electrophoresis
    Belder, D
    Ludwig, M
    [J]. ELECTROPHORESIS, 2003, 24 (21) : 3595 - 3606
  • [4] Protein sizing on a microchip
    Bousse, L
    Mouradian, S
    Minalla, A
    Yee, H
    Williams, K
    Dubrow, R
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (06) : 1207 - 1212
  • [5] An integrated fluorescence detection system in poly(dimethylsiloxane) for microfluidic applications
    Chabinyc, ML
    Chiu, DT
    McDonald, JC
    Stroock, AD
    Christian, JF
    Karger, AM
    Whitesides, GM
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (18) : 4491 - 4498
  • [6] Development of a multichannel microfluidic analysis system employing affinity capillary electrophoresis for immunoassay
    Cheng, SB
    Skinner, CD
    Taylor, J
    Attiya, S
    Lee, WE
    Picelli, G
    Harrison, DJ
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (07) : 1472 - 1479
  • [7] Ultrafast analysis of oligosaccharides on microchip with light-emitting diode confocal fluorescence detection
    Dang, F
    Zhang, L
    Hagiwara, H
    Mishina, Y
    Baba, Y
    [J]. ELECTROPHORESIS, 2003, 24 (04) : 714 - 721
  • [8] Replica multichannel polymer chips with a network of sacrificial channels sealed by adhesive printing method
    Dang, F
    Shinohara, S
    Tabata, O
    Yamaoka, Y
    Kurokawa, M
    Shinohara, Y
    Ishikawa, M
    Baba, Y
    [J]. LAB ON A CHIP, 2005, 5 (04) : 472 - 478
  • [9] Characterization of electrophoretic behavior of sugar isomers by microchip electrophoresis coupled with videomicroscopy
    Dang, FQ
    Zhang, LH
    Jabasini, M
    Kaji, N
    Baba, Y
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (10) : 2433 - 2439
  • [10] High-performance genetic analysis on microfabricated capillary array electrophoresis plastic chips fabricated by injection molding
    Dang, FQ
    Tabata, O
    Kurokawa, M
    Ewis, AA
    Zhang, LH
    Yamaoka, Y
    Shinohara, S
    Shinohara, Y
    Ishikawa, M
    Baba, Y
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (07) : 2140 - 2146