Stent Fracture After Sirolimus-Eluting Stent Implantation 8-Year Clinical Outcomes

被引:17
作者
Ohya, Masanobu [1 ]
Kadota, Kazushige [1 ]
Tada, Takeshi [1 ]
Habara, Seiji [1 ]
Shimada, Takenobu [1 ]
Amano, Hidewo [1 ]
Izawa, Yu [1 ]
Hyodo, Yusuke [1 ]
Miyake, Koshi [1 ]
Otsuru, Suguru [1 ]
Hasegawa, Daiji [1 ]
Tanaka, Hiroyuki [1 ]
Maruo, Takeshi [1 ]
Katoh, Harumi [1 ]
Fuku, Yasushi [1 ]
Goto, Tsuyoshi [1 ]
Mitsudo, Kazuaki [1 ]
机构
[1] Kurashiki Cent Hosp, Dept Cardiol, Kurashiki, Okayama 7108602, Japan
关键词
angiography; drug-eluting stent; myocardial infarction; percutaneous coronary intervention; stent fracture; CARDIAC EVENTS; THROMBOSIS; IMPACT; PREDICTORS; REVASCULARIZATION;
D O I
10.1161/CIRCINTERVENTIONS.115.002664
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Stent fracture (SF) after sirolimus-eluting stent implantation is reported to be associated with target lesion revascularization (TLR) and stent thrombosis. We aimed to assess the clinical impact of SF at 8 years. Methods and Results Between 2002 and 2005, 972 patients (1795 lesions) underwent sirolimus-eluting stent implantation and follow-up angiography within 1 year after index procedure. SF, defined as the complete separation of stent segments or stent struts at follow-up angiography, was observed in 105 lesions (5.8%). The study sample comprised 954 patients (1630 lesions), excluding 147 lesions undergoing TLR and 18 patients (18 lesions) who died or in whom stent thrombosis developed within 1 year after sirolimus-eluting stent implantation. The median follow-up duration was 9.1 years (the first and third quarters, 8.7 and 9.4 years). The primary end point was defined as any TLR. The 8-year cumulative rates of adverse events were estimated by Kaplan-Meier methods with P values from log-rank tests. Between patients with and without SF, there were no significant differences in the cumulative rates of all-cause death (23.5% versus 27.6%, P=0.35) and cardiac death (4.7% versus 9.1%, P=0.14), whereas patients with SF had significantly higher cumulative rates in myocardial infarction (10.1% versus 3.3%, P=0.001), very late stent thrombosis (6.8% versus 0.7%, P<0.001), any TLR (38.1% versus 10.8%, P<0.001), and clinically driven TLR (26.2% versus 6.6%, P<0.001). Conclusions SF after sirolimus-eluting stent implantation was consistently associated with higher rates of adverse cardiac events during the 8-year follow-up.
引用
收藏
页数:7
相关论文
共 24 条
  • [1] Meta-Analysis of Incidence, Clinical Characteristics and Implications of Stent Fracture
    Chakravarty, Tarun
    White, Anthony J.
    Buch, Mamta
    Naik, Hursh
    Doctor, Niraj
    Schapira, Jay
    Kar, Saibal
    Forrester, James S.
    Weiss, Robert E.
    Makkar, Raj
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (08) : 1075 - 1080
  • [2] The incidence and clinical impact of stent strut fractures developed after drug-eluting stent implantation
    Chung, Wook-Sung
    Park, Chul-Soo
    Seung, Ki-Bae
    Kim, Pum-Joon
    Lee, Jong-Min
    Koo, Bon-Kwon
    Jang, Yang-Soo
    Yang, Joo-Young
    Yoon, Jung-Han
    Kim, Doo-Il
    Yoon, Young-Won
    Park, Jong-Seon
    Cho, Yoon-Haeng
    Park, Seung-Jung
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 125 (03) : 325 - 331
  • [3] Clinical end points in coronary stent trials - A case for standardized definitions
    Cutlip, Donald E.
    Windecker, Stephan
    Mehran, Roxana
    Boam, Ashley
    Cohen, David J.
    van Es, Gerrit-Anne
    Steg, P. Gabriel
    Morel, Marie-angele
    Mauri, Laura
    Vranckx, Pascal
    McFadden, Eugene
    Lansky, Alexandra
    Hamon, Martial
    Krucoff, Mitchell W.
    Serruys, Patrick W.
    [J]. CIRCULATION, 2007, 115 (17) : 2344 - 2351
  • [4] Incidence and Predictors for Late Target Lesion Revascularization After Sirolimus-Eluting Stent Implantation
    Hara, Hironori
    Aoki, Jiro
    Tanabe, Kengo
    Tanimoto, Shuzou
    Nakajima, Yoshifumi
    Yahagi, Kazuyuki
    Nakashima, Makoto
    Hashimoto, Takuya
    Asami, Masahiko
    Watanabe, Mika
    Yoshida, Eri
    Nakajima, Hiroyoshi
    Hara, Kazuhiro
    [J]. CIRCULATION JOURNAL, 2013, 77 (04) : 988 - 994
  • [5] Incidence, Risk Factors, and Clinical Sequelae of Angiographic Peri-Stent Contrast Staining After Sirolimus-Eluting Stent Implantation
    Imai, Masao
    Kadota, Kazushige
    Goto, Tsuyoshi
    Fujii, Satoki
    Yamamoto, Hiroyuki
    Fuku, Yasushi
    Hosogi, Shingo
    Hirono, Akitoshi
    Tanaka, Hiroyuki
    Tada, Takeshi
    Morimoto, Takeshi
    Shiomi, Hiroki
    Kozuma, Ken
    Inoue, Katsumi
    Suzuki, Nobuaki
    Kimura, Takeshi
    Mitsudo, Kazuaki
    [J]. CIRCULATION, 2011, 123 (21) : 2382 - 2391
  • [6] Predictors and Prognosis of Stent Fracture After Sirolimus-Eluting Stent Implantation
    Ino, Yasushi
    Toyoda, Yasuaki
    Tanaka, Atsushi
    Ishii, Shuuta
    Kusuyama, Yoshio
    Kubo, Takashi
    Takarada, Shigeho
    Kitabata, Hironori
    Tanimoto, Takashi
    Mizukoshi, Masato
    Imanishi, Toshio
    Akasaka, Takashi
    [J]. CIRCULATION JOURNAL, 2009, 73 (11) : 2036 - 2041
  • [7] Impact of sirolimus-eluting stent fractures without early cardiac events on long-term clinical outcomes: A multislice computed tomography study
    Ito, Tsuyoshi
    Kimura, Masashi
    Ehara, Mariko
    Terashima, Mitsuyasu
    Nasu, Kenya
    Kinoshita, Yoshihisa
    Habara, Maoto
    Tsuchikane, Etsuo
    Suzuki, Takahiko
    [J]. EUROPEAN RADIOLOGY, 2014, 24 (05) : 1006 - 1012
  • [8] Very Late Sirolimus-Eluting Stent Thrombosis Due to Stent Fracture and Late-Acquired Incomplete Stent Apposition Detected on Multislice Computed Tomography
    Ito, Tsuyoshi
    Terashima, Mitsuyasu
    Kaneda, Hideaki
    Nasu, Kenya
    Kinoshita, Yoshihisa
    Habara, Maoto
    Tsuchikane, Etsuo
    Suzuki, Takahiko
    [J]. CIRCULATION JOURNAL, 2011, 75 (11) : 2716 - 2717
  • [9] Long-term safety and efficacy of sirolimus-eluting stents versus bare-metal stents in real world clinical practice in Japan
    Kimura T.
    Morimoto T.
    Furukawa Y.
    Nakagawa Y.
    Kadota K.
    Iwabuchi M.
    Shizuta S.
    Shiomi H.
    Tada T.
    Tazaki J.
    Kato Y.
    Hayano M.
    Abe M.
    Tamura T.
    Shirotani M.
    Miki S.
    Matsuda M.
    Takahashi M.
    Ishii K.
    Tanaka M.
    Aoyama T.
    Doi O.
    Hattori R.
    Tatami R.
    Suwa S.
    Takizawa A.
    Takatsu Y.
    Takahashi M.
    Kato H.
    Takeda T.
    Lee J.-D.
    Nohara R.
    Ogawa H.
    Tei C.
    Horie M.
    Kambara H.
    Fujiwara H.
    Mitsudo K.
    Nobuyoshi M.
    Kita T.
    [J]. Cardiovascular Intervention and Therapeutics, 2011, 26 (3) : 234 - 245
  • [10] Incidence and Clinical Impact of Stent Fracture After the Nobori Biolimus-Eluting Stent Implantation
    Kuramitsu, Shoichi
    Iwabuchi, Masashi
    Yokoi, Hiroyoshi
    Domei, Takenori
    Sonoda, Shinjo
    Hiromasa, Takashi
    Morinaga, Takashi
    Kobayashi, Yohei
    Ohe, Kensuke
    Goya, Kaoru
    Yamaji, Kyohei
    Hyodo, Makoto
    Soga, Yoshimitsu
    Kondo, Katsuhiro
    Shirai, Shinichi
    Ando, Kenji
    Sakai, Koyu
    Nobuyoshi, Masakiyo
    [J]. JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2014, 3 (02): : e000703