Voltammetric monitoring of electrochemical reduction of riboflavin using silver solid amalgam electrodes

被引:56
作者
Bandzuchova, Lenka [1 ]
Selesovska, Renata [1 ]
Navratil, Tomas [2 ]
Chylkova, Jaromira [1 ]
Novotny, Ladislav [1 ]
机构
[1] Univ Pardubice, Fac Chem Technol, Inst Environm & Chem Engn, Pardubice 53210, Czech Republic
[2] J Heyrovsky Inst Phys Chem AS CR, Vvi, Prague 18223 8, Czech Republic
关键词
Riboflavin; Determination; Mercury meniscus modified silver solid amalgam electrode; Polished silver solid amalgam electrode; Differential pulse voltammetry; ADSORPTIVE STRIPPING VOLTAMMETRY; ELIMINATION VOLTAMMETRY; COMPOSITE ELECTRODE; FOLIC-ACID; CHROMATOGRAPHIC DETERMINATION; PHOTOCHEMICAL DEGRADATION; AQUEOUS-SOLUTION; LINEAR SCAN; DNA; SPECTROSCOPY;
D O I
10.1016/j.electacta.2012.05.009
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The voltammetric behavior of riboflavin (RF), an important compound belonging to the group of vitamins B, has been investigated using mercury meniscus modified electrode (m-AgSAE) and polished silver solid amalgam electrode (p-AgSAE). Obtained results were compared with those obtained using hanging mercury drop electrode (HMDE). Cyclic voltammetry (CV), direct current voltammetry (DCV) and differential pulse voltammetry (DPV) have been applied for investigation of electrochemical behavior of RF on the above mentioned electrodes. Optimum conditions for DPV determination of RF have been found in acetate buffer of pH 5 for m-AgSAE and HMDE, and in Britton-Robinson (BR) buffer of pH 3 for p-AgSAE. The limits of detection amounted to 8.2 x 10(-10) mol L-1 (m-AgSAE) and 1.3 x 10(-9) mol L-1 (p-AgSAE). DPV with optimized parameters was utilized for successful determination of RF in 2 vitamin preparations. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:316 / 324
页数:9
相关论文
共 65 条
[1]   Photolysis of riboflavin in aqueous solution: a kinetic study [J].
Ahmad, I ;
Fasihullah, Q ;
Noor, A ;
Ansari, IA ;
Ali, QNM .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2004, 280 (1-2) :199-208
[2]   Voltammetric determination of riboflavin in vitaminized supplements and feeds [J].
Anisimova, LS ;
Mikheeva, EV ;
Slipchenko, VF .
JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 56 (07) :658-662
[3]   Riboflavin and flavin mononucleotide adsorption on Ag (111) electrodes and their interaction with L-cysteine investigated by electrochemical and non-linear optical methods [J].
Avalle, Lucia B. ;
Valle, Lorena .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 662 (02) :288-297
[4]   Electrochemical behavior of folic acid on mercury meniscus modified silver solid amalgam electrode [J].
Bandzuchova, L. ;
Selesovska, R. ;
Navratil, T. ;
Chylkova, J. .
ELECTROCHIMICA ACTA, 2011, 56 (05) :2411-2419
[5]  
Bandzuchová L, 2011, ACTA CHIM SLOV, V58, P776
[6]   Nontraditional electrode materials in environmental analysis of biologically active organic compounds [J].
Barek, Jiri ;
Fischer, Jan ;
Navratil, Tomas ;
Peckova, Karolina ;
Yosypchuk, Bogdan ;
Zima, Jiri .
ELECTROANALYSIS, 2007, 19 (19-20) :2003-2014
[7]   Front-face fluorescence spectroscopy and chemometrics in analysis of yogurt: Rapid analysis of riboflavin [J].
Becker, EM ;
Christensen, J ;
Frederiksen, CS ;
Haugaard, VK .
JOURNAL OF DAIRY SCIENCE, 2003, 86 (08) :2508-2515
[8]  
CAIRNS WL, 1971, J AM CHEM SOC, V93, P2772
[9]   Simultaneous square-wave voltammetric determination of riboflavin and folic acid in pharmaceutical preparations [J].
Cakir, S ;
Atayman, I ;
Cakir, O .
MIKROCHIMICA ACTA, 1997, 126 (3-4) :237-240
[10]   Biological applications of diamond electrodes; electrochemical studies of riboflavin [J].
Chatterjee, A. ;
Foord, J. S. .
DIAMOND AND RELATED MATERIALS, 2009, 18 (5-8) :899-903