High-cycle fatigue behavior of thin-walled CoCr tubes

被引:10
作者
Khatibi, G. [1 ]
Lederer, M. [1 ]
Kotas, A. Betzwar [1 ]
Frotscher, M. [2 ]
Krause, A. [2 ]
Poehlmann, S. [2 ]
机构
[1] Vienna Univ Technol, A-1060 Vienna, Austria
[2] Cortronik GmbH, D-18119 Rostock, Germany
关键词
CoCr alloy; High cycle fatigue; Stents; Stress concentration; FEM; STENT; LIFE;
D O I
10.1016/j.ijfatigue.2015.05.013
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Thin-walled tubes made of the biocompatible Cobalt-Chromium alloy L605 are being used as the starting material for manufacturing of stents with fine struts of about 100 mu m due to their excellent mechanical properties. The required long-term reliability of these medical implants is endurance of 4. 10(8) loading cycles without failure. Knowledge of the high-cycle fatigue properties of the tubing material used for the stent fabrication is a prerequisite for optimization of these high quality products during the stages of design and fabrication. In the present study, the high-cycle fatigue behavior of thin-walled tubes of CoCr L605 was studied by using an ultrasonic resonance fatigue testing system. Laser cutting technique was used to introduce holes in the midsection of the tubes followed by electro-polishing and passive coating processes. Standard stent manufacturing processes were applied for preparation of the tube samples, ensuring representative microstructures and mechanical properties to final stent products. Vibrometry measurements and finite element simulations were conducted to analyze the overall modal response of the tubes during the vibrational loading and to calculate the stress-strain distribution in the periphery of the holes. A lifetime prediction model covering the low- and high-cycle fatigue regime is proposed, based on the experimentally obtained high-cycle fatigue curves in combination with the literature data and finite element modeling. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:103 / 112
页数:10
相关论文
共 32 条
  • [1] [Anonymous], 1995, G951 US FOOD DRUG AD
  • [2] [Anonymous], 2009, 1200631998A1 EN
  • [3] [Anonymous], 2014, F9014 ASTM
  • [4] Bansemir H, 1999, FATIGUE SUBSTANTIATI
  • [5] Bathias C., 2005, MECH ENG SE
  • [6] Very high cycle regime fatigue of thin walled tubes made from austenitic stainless steel
    Carstensen, JV
    Mayer, H
    Brondsted, P
    [J]. FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES, 2002, 25 (8-9) : 837 - 844
  • [7] Laser Doppler Vibrometry: Development of advanced solutions answering to technology's needs
    Castellini, P.
    Martarelli, M.
    Tomasini, E. P.
    [J]. MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2006, 20 (06) : 1265 - 1285
  • [8] A review of deformation and fatigue of metals at small size scales
    Connolley, T
    McHugh, PE
    Bruzzi, M
    [J]. FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES, 2005, 28 (12) : 1119 - 1152
  • [9] Fan Sun, 2014, Materials Science Forum, V783-786, P1354, DOI 10.4028/www.scientific.net/MSF.783-786.1354
  • [10] Gong XY, 2009, FATIGUE FRACTURE INF