More precise diagnosis of access stenosis: ultrasonography versus angiography

被引:30
作者
Kudlicka, Jaroslav [1 ,2 ]
Kavan, Jan [3 ]
Tuka, Vladimir [2 ]
Malik, Jan [2 ]
机构
[1] Gen Univ Hosp, Dept Internal Med 3, Prague 12808 2, Czech Republic
[2] Charles Univ Prague, Fac Med 1, Dept Internal Med 3, Prague, Czech Republic
[3] Charles Univ Prague, Fac Med 1, Dept Radiol, Prague, Czech Republic
关键词
Angiography; Duplex Doppler ultrasound; Hemodialysis vascular access; Residual diameter; Significant stenosis; HEMODIALYSIS VASCULAR ACCESS; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY; INTERNAL CAROTID-ARTERY; ULTRASOUND SURVEILLANCE; NEOINTIMAL HYPERPLASIA; ARTERIOVENOUS GRAFTS; BLOOD-FLOW; SHORT-TERM; PATHOPHYSIOLOGY; PATENCY;
D O I
10.5301/jva.5000047
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Purpose: Patency of mature vascular access for hemodialysis is mostly limited by the growing stenoses leading to acute access thrombosis. The therapy of choice is usually percutaneous balloon angioplasty (PTA). However, PTA injures the vessel wall and subsequent re-stenosis develops faster than de novo stenosis. Therefore, the key is in appropriate timing of PTA procedures - as late as possible but before access thrombosis develops. Ultrasonography combines the morphologic and functional access assessment, but the former is less precise than angiography. The aim of this study was to compare ultrasonographic and angiographic measuring of residual diameter as the additional criterion of significant stenoses used in our center. Methods: Residual diameter of significant stenoses was measured by B-mode ultrasonography three times in 20 patients. All the patients were indicated for angiography and the residual diameter of the stenoses was re-analyzed by this method. The repeatability of ultrasonographic residual diameter measurements and reproducibility in comparison to angiography were expressed by coefficients of variation (CV). Results: The residual diameter was 1.69 +/- 0.05 mm by ultrasound and 1.65 +/- 0.59 mm measured by angiography. In the ultrasound repeatability study, CV was 3.17 +/- 2.76% and in the reproducibility study CV was 18.0 +/- 15.6%. All the stenoses found to be significant by ultrasound were above 65% by angiography and PTA was performed. Conclusions: Ultrasonographic measurement of the residual diameter is stable in experienced hands and is well comparable to angiography results. These findings advocate residual diameter of 2.0 mm as the strong additional criterion of the significant stenoses, which can also be used in ultrasound surveillance of arteriovenous grafts.
引用
收藏
页码:310 / 314
页数:5
相关论文
共 24 条
[1]   Hemodialysis vascular access monitoring: Current concepts [J].
Allon, Michael ;
Robbin, Michelle L. .
HEMODIALYSIS INTERNATIONAL, 2009, 13 (02) :153-162
[2]   Angioplasty for arteriovenous grafts and fistulae [J].
Beathard, GA .
SEMINARS IN NEPHROLOGY, 2002, 22 (03) :202-210
[3]   Highly increased cell proliferation activity in the restenotic hemodialysis vascular access after percutaneous transluminal angioplasty: Implication in prevention of restenosis [J].
Chang, CJ ;
Ko, PJ ;
Hsu, LA ;
Ko, YS ;
Ko, YL ;
Chen, CF ;
Huang, CC ;
Hsu, TS ;
Lee, YS ;
Pang, JHS .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2004, 43 (01) :74-84
[4]   STENOSIS OF THE INTERNAL CAROTID-ARTERY - ASSESSMENT USING COLOR DOPPLER IMAGING COMPARED WITH ANGIOGRAPHY [J].
ERICKSON, SJ ;
MEWISSEN, MW ;
FOLEY, WD ;
LAWSON, TL ;
MIDDLETON, WD ;
QUIROZ, FA ;
MACRANDER, SJ ;
LIPCHIK, EO .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (06) :1299-1305
[5]   Advances and New Frontiers in the Pathophysiology of Venous Neointimal Hyperplasia and Dialysis Access Stenosis [J].
Lee, Timmy ;
Roy-Chaudhury, Prabir .
ADVANCES IN CHRONIC KIDNEY DISEASE, 2009, 16 (05) :329-338
[6]   Prophylactic balloon angioplasty fails to prolong the patency of expanded polytetrafluoroethylene arteriovenous grafts: Results of a prospective randomized study [J].
Lumsden, AB ;
MacDonald, MJ ;
Kikeri, D ;
Cotsonis, GA ;
Harker, LA ;
Martin, LG .
JOURNAL OF VASCULAR SURGERY, 1997, 26 (03) :382-390
[7]   Regular ultrasonographic screening significantly prolongs patency of PTFE grafts [J].
Malik, J ;
Slavikova, M ;
Svobodova, J ;
Tuka, V .
KIDNEY INTERNATIONAL, 2005, 67 (04) :1554-1558
[8]   Low-Flow Polytetrafluoroethylene Accesses: Ultrasound Surveillance and Preemptive Interventions Ensure Long-Term Patency [J].
Malik, Jan ;
Tuka, Vladimir ;
Chytilova, Eva ;
Mokrejsova, Magdalena ;
Masek, Martin ;
Slavikova, Marcela .
KIDNEY & BLOOD PRESSURE RESEARCH, 2010, 33 (03) :181-185
[9]   INTERNAL CAROTID-ARTERY STENOSIS - ACCURACY AND REPRODUCIBILITY OF COLOR-DOPPLER-ASSISTED DUPLEX IMAGING [J].
POLAK, JF ;
DOBKIN, GR ;
OLEARY, DH ;
WANG, AM ;
CUTLER, SS .
RADIOLOGY, 1989, 173 (03) :793-798
[10]   A randomized controlled trial of blood flow and stenosis surveillance of hemodialysis grafts [J].
Ram, SJ ;
Work, J ;
Caldito, GC ;
Eason, JM ;
Pervez, A ;
Paulson, WD .
KIDNEY INTERNATIONAL, 2003, 64 (01) :272-280