Localising rectus muscle insertions using high frequency wide-field ultrasound biomicroscopy

被引:22
作者
Khan, Hayat Ahmad
Smith, David R.
Kraft, Stephen P. [1 ]
机构
[1] Hosp Sick Children, Dept Ophthalmol & Vis Sci, Toronto, ON M5G 1X8, Canada
关键词
STRABISMUS; REOPERATIONS; AGREEMENT;
D O I
10.1136/bjophthalmol-2011-300960
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim The ultrasound biomicroscope (UBM) can accurately locate an extraocular muscle (EOM) insertion. The authors compared the accuracy of the Sonomed UBM (SUBM), a new 'wide-field ultrasound biomicroscope', with the older model Humphrey UBM (HUBM) in localising EOM insertions and compared their ranges of detection of muscle insertions. Methods Prospective, double-masked, observational study of 27 patients undergoing primary (n=40 muscles) or repeat (n=10 muscles) horizontal or vertical rectus muscle surgery. EOM insertional distances were measured with SUBM, and then intraoperatively with callipers. A Bland-Altman analysis and intraclass correlation coefficient were used to compare the SUBM and surgical data. Results For all muscles, the differences between SUBM and surgery measurements were less than 1.0 mm. The mean of the SUBM insertion distances was 6.67 mm (SD 1.65 mm) versus 6.7 mm (SD 1.6 mm) at surgery. The intraclass correlation coefficient showed 'excellent' correlation between the two sets of data and was higher than that reported with HUBM. The image quality with the SUBM was superior to the HUBM, and its range of field was much larger (14x18 mm vs 5x6 mm). Conclusion The SUBM with its smaller, more manoeuvrable probe handpiece and a wider scanning field was more accurate in detecting muscle insertions compared with HUBM.
引用
收藏
页码:683 / 687
页数:5
相关论文
共 12 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Ultrasound biomicroscopy in strabismus reoperations [J].
Dai, Shuan ;
Kraft, Stephen P. ;
Smith, David R. ;
Buncic, J. Raymond .
JOURNAL OF AAPOS, 2006, 10 (03) :202-205
[3]   COMPARISON OF STANDARDIZED ECHOGRAPHY WITH MAGNETIC-RESONANCE-IMAGING TO MEASURE EXTRAOCULAR-MUSCLE SIZE [J].
DEMER, JL ;
KERMAN, BM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1994, 118 (03) :351-361
[4]   High-resolution magnetic resonance imaging of the normal extraocular musculature [J].
Ettl, A ;
Kramer, J ;
Daxer, A ;
Koornneef, L .
EYE, 1997, 11 (6) :793-797
[5]  
HELVESTON EM, 1979, OPHTHALMOLOGY, V86, P1379
[6]   Quantitative CT of the orbit in Graves' disease [J].
Özgen, A ;
Alp, MN ;
Ariyürek, M ;
Tütüncü, NB ;
Can, I ;
Günalp, I .
BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (860) :757-762
[7]   Normative measurements of orbital structures using MRI [J].
Özgen, A ;
Aydingöz, Ü .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (03) :493-496
[8]  
Pavlin CJ, 1995, ULTRASOUND BIOMICROS, P50
[9]   Evaluation of vertical rectus muscles using ultrasound biomicroscopy [J].
Solarte, Carlos Eduardo ;
Smith, David R. ;
Buncic, J. Raymond ;
Tehrani, Nasrin Najm ;
Kraft, Stephen P. .
JOURNAL OF AAPOS, 2008, 12 (02) :128-131
[10]   Ultrasound of the horizontal rectus muscle insertion sites: Implications in preoperative assessment of strabismus [J].
Tamburrelli, C ;
Salgarello, T ;
Vaiano, AS ;
Scullica, L ;
Palombi, M ;
Bagolini, B .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (02) :618-622