A comparative study of non-enzymatic glucose detection in artificial human urine and human urine specimens by using mesoporous bimetallic cobalt-iron supported N-doped graphene biosensor based on differential pulse voltammetry

被引:37
作者
Janyasupab, Metini [1 ]
Liu, Chen-Wei [2 ]
Chanlek, Narong [3 ]
Chio-Srichan, Sirinart [3 ]
Promptmas, Chamras [4 ]
Surareungchai, Werasak [5 ,6 ]
机构
[1] King Mongkuts Inst Technol Ladkrabang, Fac Engn, Dept Elect Engn, Bangkok 10520, Thailand
[2] Ind Technol Res Inst, Green Energy & Environm Res Labs, Hsinchu 310, Taiwan
[3] Synchrotron Light Res Inst Publ Org, Nakhon Ratchasima 30000, Thailand
[4] Mahidol Univ, Dept Biomed Engn, Nakhon Pathom 73170, Thailand
[5] King Mongkuts Univ Technol Thonburi, Sch Bioresources & Technol, Bangkok 10150, Thailand
[6] King Mongkuts Univ Technol Thonburi, Fac Sci, Nanosci & Nanotechnol Grad Program, Bangkok 10140, Thailand
关键词
Bimetallic catalyst; Non-enzymatic detection; Glucose in urine; ELECTROCHEMICAL DETECTION; FACILE SYNTHESIS; OXIDE; SENSOR; NANOPARTICLES; EFFICIENT; DEPOSITION; CARBON; PERFORMANCE; NANOFLOWERS;
D O I
10.1016/j.snb.2019.02.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Development of non-invasive glucose measurement allows future advancement of smart sensing platform for diagnostic technology. Especially for endocrine disorders, advanced kidney diseases, and diabetes, monitoring excessive glucose level in urine can provide invaluable information for clinical prognosis and preventive healthcare. Herein, we present a comparative electrochemical study of cobalt/iron (CoFe) catalyst on nitrogen-doped graphene (NG) for non-enzymatic glucose detection, carried out in physiological pH urine including (i) modified artificial urine medium (mAUM), (ii) commercial standard urine (Surine), and (iii) human urine specimens. With no requirement of strong alkaline addition, catalytic properties of CoFe-NG were assessed by using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) on a glassy carbon rotating disk electrode. Upon successive glucose additions from 0 to 3 mM, DPV results revealed two anodic peaks at +0.18 V and +0.42 V versus Ag/AgCl, corresponding to Co3+ and Co4+ as a result of glucose binding in urine. By evaluating at +0.18 V, the sensitivities of CoFe-NG were estimated to be 16.77 (R-2 = 0.987), 45.36 (R-2 = 0.988), and 20.26 (R-2 = 0.991) mu A mM(-1) cm(-2) with the limit of detection of 0.25, 0.07, and 0.19 mM in mAUM, Surine, and human urine specimen with low serum creatinine, respectively. Furthermore, the effects of CoFe on graphene (G) and carbon Vulcan XC-72 (C) were also studied in comparison of NG on the bimetal. Interestingly, CoFe-C showed a good electrochemical trend in glucose detection in urine. However, negligible catalytic activity was presented in CoFe-G. Thus, electrochemical responses of CoFe-C were also further studied in the comparison of CoFe-NG in each type of urine. Overall, CoFe-NG outperformed CoFe-C in all types of urine and exhibited an excellent anti-interference property toward uric acid, thereby suggesting great potential for the next generation of glucose sensing platform in urine.
引用
收藏
页码:550 / 563
页数:14
相关论文
共 65 条
[1]   One-step electrochemical deposition of Polypyrrole-Chitosan-Iron oxide nanocomposite films for non-enzymatic glucose biosensor [J].
AL-Mokaram, Ali M. A. Abdul Amir ;
Yahya, Rosiyah ;
Abdi, Mahnaz M. ;
Mahmud, Habibun Nabi Muhammad Ekramul .
MATERIALS LETTERS, 2016, 183 :90-93
[2]   Increasing prevalence of diabetes mellitus in a developing country and its related factors [J].
Animaw, Worku ;
Seyoum, Yeshaneh .
PLOS ONE, 2017, 12 (11)
[3]  
Arndt P., 2017, J BIOMED MAT RES B
[4]  
Baby T. T., 2011, NAN TECHN SOC IMPL N, P1
[5]   A novel hierarchical 3D N-Co-CNT@NG nanocomposite electrode for non enzymatic glucose and hydrogen peroxide sensing applications [J].
Balamurugan, Jayaraman ;
Tran Duy Thanh ;
Karthikeyan, Gopalsamy ;
Kim, Nam Hoon ;
Lee, Joong Hee .
BIOSENSORS & BIOELECTRONICS, 2017, 89 :970-977
[6]   A simple artificial urine for the growth of urinary pathogens [J].
Brooks, T ;
Keevil, CW .
LETTERS IN APPLIED MICROBIOLOGY, 1997, 24 (03) :203-206
[7]   A novel non-enzymatic glucose sensor modified with Fe2O3 nanowire arrays [J].
Cao, Xia ;
Wang, Ning .
ANALYST, 2011, 136 (20) :4241-4246
[8]   Study of the electrochemical deposition and properties of cobalt oxide species in citrate alkaline solutions [J].
Casella, IG ;
Gatta, M .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 534 (01) :31-38
[9]   Non-enzymatic electrochemical detection of glucose with a disposable paper-based sensor using a cobalt phthalocyanine ionic liquid graphene composite [J].
Chaiyo, Sudkate ;
Mehmeti, Eda ;
Siangproh, Weena ;
Thai Long Hoang ;
Hai Phong Nguyen ;
Chailapakul, Orawon ;
Kalcher, Kurt .
BIOSENSORS & BIOELECTRONICS, 2018, 102 :113-120
[10]   Surface-modified cobalt oxide nanoparticles: New opportunities for anti-cancer drug development [J].
S. Chattopadhyay ;
S. P. Chakraborty ;
D. Laha ;
R. Baral ;
P. Pramanik ;
S. Roy .
Cancer Nanotechnology, 2012, 3 (1-6) :13-23