A food contaminant detection system based on high-Tc SQUIDs

被引:20
作者
Tanaka, S
Fujita, H
Hatsukade, Y
Nagaishi, T
Nishi, K
Ota, H
Otani, T
Suzuki, S
机构
[1] Toyohashi Univ Technol, Toyohashi, Aichi 4418580, Japan
[2] Sumitomo Elect Hightechs Co Ltd, Itami, Hyogo 6640016, Japan
[3] Adv Food Technol Co Ltd, Toyohashi, Aichi 4418113, Japan
关键词
D O I
10.1088/0953-2048/19/5/S24
中图分类号
O59 [应用物理学];
学科分类号
摘要
We have designed and constructed a computer controlled food contaminant detection system for practical use, based on high-T-c SQUID detectors. The system, which features waterproof stainless steel construction, is acceptable under the HACCP (Hazard Analysis and Critical Control Point) programme guidelines. The outer dimensions of the system are 1500 mm length x 477 mm width x 1445 mm height, and it can accept objects up to 200 mm wide x 80 mm high. An automatic liquid nitrogen filling system was installed in the standard model. This system employed a double-layered permeable metallic shield with a thickness of 1 mm as a magnetically shielded box. The distribution of the magnetic field in the box was simulated by FEM; the gap between each shield layer was optimized before fabrication. A shielding factor of 732 in the Z-component was achieved. This value is high enough to safely operate the system in a non-laboratory environment, i.e., a factory. During testing, we successfully detected a steel contaminant as small as 0.3 mm in diameter at a distance of 75 mm.
引用
收藏
页码:S280 / S283
页数:4
相关论文
共 7 条
[1]  
BICK M, 2003, ISEC03
[2]  
DONALDSON GB, 1996, FUNDAMENTALS APPL, P599
[3]   3D NONLINEAR MAGNETOSTATIC ANALYSIS OF A DOUBLE-WALLED CYLINDRICAL SHIELD [J].
FAURI, M ;
SONATO, P .
IEEE TRANSACTIONS ON MAGNETICS, 1990, 26 (02) :364-367
[4]   Microstructural evolution of 304 stainless steel during mechanical milling [J].
Huang, H ;
Ding, J ;
McCormick, PG .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 1996, 216 (1-2) :178-184
[5]   Appearance of sign reversal in geophysical transient electromagnetics with a SQUID due to stacking [J].
Krause, HJ ;
Panaitov, GI ;
Zhang, Y ;
Bick, M .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (02) :745-748
[6]   Measurement of metallic contaminants in food with a high-Tc SQUID [J].
Tanaka, S ;
Natsume, M ;
Uchida, M ;
Hotta, N ;
Matsuda, T ;
Spanut, ZA ;
Hatsukade, Y .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2004, 17 (04) :620-623
[7]   High-Tc SQUID metal detection system for food and pharmaceutical contaminants [J].
Tanaka, S ;
Kudo, S ;
Hansukade, Y ;
Nagaishi, T ;
Nishi, K ;
Ota, H ;
Suzuki, S .
IEICE TRANSACTIONS ON ELECTRONICS, 2005, E88C (02) :175-179