end-tidal carbon dioxide; capnography; capnometer; monitoring; carbon dioxide; blood gas analysis; CARBON-DIOXIDE; ARTERIAL; TRAUMA; CAPNOGRAPHY; CARE;
D O I
10.1016/j.jemermed.2012.11.019
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The determination of end-tidal carbon dioxide (etCO(2)) is very helpful in cardiac resuscitation for confirmation and monitoring of endotracheal tube placement and as an indicator of return of circulation and effectiveness of chest compressions. There is now also widespread use of capnometry on-site at emergency and trauma fields. Objective: We studied the accuracy and correlation of three capnometers (EMMA, Medtronic, and Evita) with partial pressure of arterial CO2 (PaCO2) measurements. Methods: The three capnometers were placed in-line in the ventilator tubing of the patient. Forty sedated and mechanically ventilated post-cardiac surgery patients were studied. Twenty consecutive etCO(2) values were collected simultaneously from all three monitors while drawing an arterial blood sample. Paired sample t-test and Pearson correlation were used to compare the capnometers and their correlation with PaCO2. Results: The correlation of etCO(2) measurements between all three capnometers was good (Emma vs. Evita: 0.874, Emma vs. Medtronic: 0.949, Evita vs. Medtronic: 0.878). The correlation of PaCO2 with the Evita is the lowest (0.671) as compared to the EMMA (0.693) and the Medtronic (0.727). The lowest dispersion of the difference between etCO(2) and PaCO2 was seen in EMMA (3.30), the highest in Evita (3.98). Conclusions: A good correlation between etCO(2) and PaCO2 was shown with the three capnometers in the present study. However, etCO(2) measurements were not valid to estimate PaCO2 in these patients. Therefore, capnometry cannot be used to replace serial blood gas analyses completely, but may be a good cardiopulmonary trend monitor and alerting system in catastrophic events. (c) 2013 Elsevier Inc.
引用
收藏
页码:130 / 134
页数:5
相关论文
共 50 条
  • [21] End-Tidal CO2 as a Predictor of Survival in Out-of-Hospital Cardiac Arrest
    Eckstein, Marc
    Hatch, Lorien
    Malleck, Jennifer
    McClung, Christian
    Henderson, Sean O.
    PREHOSPITAL AND DISASTER MEDICINE, 2011, 26 (03) : 148 - 150
  • [22] The Relation of End-Tidal CO2 Values With Infarct Volume and Early Prognosis in Patients With Acute Ischemic Stroke
    Eyler, Yesim
    Kilic, Turgay Yilmaz
    Atilla, Ozge Duman
    Arslan, Yildiz
    Capar, Ahmet Ergin
    Idil, Hasan
    Suner, Asli
    NEUROLOGIST, 2022, 27 (06) : 309 - 312
  • [23] Transcutaneous CO2 versus end-tidal CO2 in neonates and infants undergoing surgery: a prospective study
    Chandrakantan, Arvind
    Jasiewicz, Ronald
    Reinsel, Ruth A.
    Khmara, Kseniya
    Mintzer, Jonathan
    DeCristofaro, Joseph D.
    Jacob, Zvi
    Seidman, Peggy
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2019, 12 : 165 - 172
  • [24] Unknown use of end-tidal CO2 in metabolic emergencies in pediatric patients
    Redant, Sebastien
    Angoulvant, Francois
    Honore, Patrick M.
    Attou, Rachid
    Biarent, Dominique
    De Bels, David
    JOURNAL OF TRANSLATIONAL INTERNAL MEDICINE, 2019, 7 (02) : 76 - 78
  • [25] NONINVASIVE MONITORING OF END-TIDAL CO2 VIA NASAL CANNULAS IN SPONTANEOUSLY BREATHING CHILDREN DURING THE PERIOPERATIVE PERIOD
    TOBIAS, JD
    FLANAGAN, JFK
    WHEELER, TJ
    GARRETT, JS
    BURNEY, C
    CRITICAL CARE MEDICINE, 1994, 22 (11) : 1805 - 1808
  • [26] Assessing the prediction of arterial CO2 from end tidal CO2 in adult blunt trauma patients
    Petrakis, Nicholas M.
    Harris, Daniel
    Ellis, Daniel Y.
    Haustead, Daniel
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (05):
  • [27] Application of End-Tidal CO2 Monitoring to ICU Management
    Owens, Bradley
    Hall, Chris
    CRITICAL CARE NURSING QUARTERLY, 2024, 47 (02) : 157 - 162
  • [28] Transcutaneous and End-Tidal CO2 Measurements in Hypoxia and Hyperoxia
    Shykoff, Barbara E.
    Lee, Lesley R.
    Gallo, Megan
    Griswold, Cheryl A.
    AEROSPACE MEDICINE AND HUMAN PERFORMANCE, 2021, 92 (11) : 864 - 872
  • [29] Relationship between variations in cardiac output and end-tidal CO2 after phenylephrine infusion in anaesthetised patients
    de Courson, Hugues
    Georges, Delphine
    Boyer, Philippe
    Futier, Emmanuel
    Biais, Matthieu
    BRITISH JOURNAL OF ANAESTHESIA, 2021, 126 (05) : E174 - E176
  • [30] Quantitative analysis of end-tidal carbon dioxide during mechanical and spontaneous ventilation in infants and young children
    Hsieh, KS
    Lee, CL
    Lin, CC
    Wu, SN
    Ko, FY
    Huang, YF
    Huang, TC
    PEDIATRIC PULMONOLOGY, 2001, 32 (06) : 453 - 458