Quantification of myocardial uptake rate constants in dynamic small-animal SPECT using a cardiac phantom

被引:4
|
作者
Johnson, Lindsay C. [1 ]
Guerraty, Marie A. [2 ]
Moore, Stephen C. [1 ]
Metzler, Scott D. [1 ]
机构
[1] Univ Penn, Dept Radiol, Perelman Sch Med, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Med, Div Cardiovasc Med, Perelman Sch Med, Philadelphia, PA 19104 USA
基金
美国国家卫生研究院;
关键词
SPECT; cardiac imaging; phantom; kinetic modeling; POSITRON-EMISSION-TOMOGRAPHY; BLOOD-FLOW; PROGNOSTIC VALUE; RESERVE;
D O I
10.1088/1361-6560/ab0472
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Myocardial blood flow and myocardial blood flow reserve (MBFR) measurements are often used clinically to quantify coronary microvascular function. Developing imaging-based methods to measure MBFR for research in mice would be advantageous for evaluating new treatment methods for coronary microvascular disease (CMVD), yet this is more challenging in mice than in humans. This work investigates microSPECT's quantitative capabilities of cardiac imaging by utilizing a multi-part cardiac phantom and applying a known kinetic model to synthesize kinetic data from static data, allowing for assessment of kinetic modeling accuracy. The phantom was designed with four main components: two left-ventricular (LV) myocardial sections and two LV blood-pool sections, sized for end-systole (ES) and end-diastole (ED). Each section of the phantom was imaged separately while acquiring list-mode data. These static, separate-compartment data were manipulated into synthetic dynamic data using a kinetic model representing the myocardium and blood-pool activity concentrations over time and then combined into a set of dynamic image frames and reconstructed. Regions of interest were drawn on the resulting images, and kinetic parameters were estimated. This process was performed for three tracer uptake values (K-1), three myocardial wall thicknesses, ten filter parameters, and 20 iterations for 25 noise ensembles. The degree of filtering and iteration number were optimized to minimize the root mean-squared error (RMSE) of K-1 values, with the largest number of iterations and minimal filtering yielding the lowest error. Using the optimized parameters, K-1 was determined with reasonable error (similar to 3% RMSE) over all wall thicknesses and K-1 input values. This work demonstrates that accurate and precise measurements of K-1 are possible for the U-SPECT+ system used in this study, for several different uptake rates and LV dimensions. Additionally, it allows for future investigation utilizing other imaging systems, including PET studies with any radiotracer, as well as with additional phantom parts containing lesions.
引用
收藏
页数:15
相关论文
共 24 条
  • [1] Cardiac Phantom for Improved Small-Animal SPECT Myocardial Blood Flow Quantification
    Johnson, Lindsay C.
    Guerraty, Marie A.
    Matej, David J.
    Metzler, Scott D.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [2] Image quality phantom and parameters for high spatial resolution small-animal SPECT
    Visser, Eric P.
    Harteveld, Anita A.
    Meeuwis, Antoi P. W.
    Disselhorst, Jonathan A.
    Beekman, Freek J.
    Oyen, Wim J. G.
    Boerman, Otto C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 654 (01) : 539 - 545
  • [3] Validation of advanced hybrid SPECT/CT system using dynamic anthropomorphic cardiac phantom
    Gelbart, Elad
    Krakovich, Alexander
    Sherm, Yigal
    Rabin, Gilad
    Ratner, Hagit
    Scheinowitz, Mickey
    Goldkorn, Ronen
    ANNALS OF NUCLEAR MEDICINE, 2024, 38 (11) : 919 - 926
  • [4] Evaluation of hardware in a small-animal SPECT system using reconstructed images
    Hesterman, Jacob Y.
    Kupinski, Matthew A.
    Clarkson, Eric
    WilSon, Donald W.
    Barrett, Harrison H.
    MEDICAL IMAGING 2007: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2007, 6515
  • [5] Quantification of Myocardial Perfusion Reserve Using Dynamic SPECT Imaging in Humans: A Feasibility Study
    Ben-Haim, Simona
    Murthy, Venkatesh L.
    Breault, Christopher
    Allie, Rayjanah
    Sitek, Arkadiusz
    Roth, Nathaniel
    Fantony, Jolene
    Moore, Stephen C.
    Park, Mi-Ae
    Kijewski, Marie
    Haroon, Athar
    Slomka, Piotr
    Erlandsson, Kjell
    Baavour, Rafael
    Zilberstien, Yoel
    Bomanji, Jamshed
    Di Carli, Marcelo F.
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (06) : 873 - 879
  • [6] Quantification of Cerebral Glucose Metabolic Rate in Mice Using 18F-FDG and Small-Animal PET
    Yu, Amy S.
    Lin, Hong-Dun
    Huang, Sung-Cheng
    Phelps, Michael E.
    Wu, Hsiao-Ming
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (06) : 966 - 973
  • [7] Development of a novel small-animal myocardial phantom can evaluate the image quality of dual-isotope simultaneous acquisition (DISA)
    Shibutani, Takayuki
    Onoguchi, Masahisa
    Kanno, Takayuki
    Wakabayashi, Hiroshi
    Hiromasa, Tomo
    Kinuya, Seigo
    ANNALS OF NUCLEAR MEDICINE, 2022, 36 (12) : 1031 - 1038
  • [8] In vivo validation of gated myocardial SPECT imaging for quantification of small hearts: comparison with cardiac MRI
    Kondo, Chisato
    Watanabe, Eri
    Momose, Mitsuru
    Fukushima, Kenji
    Abe, Koichiro
    Hagiwara, Nobuhisa
    Sakai, Shuji
    EJNMMI RESEARCH, 2016, 6 : 1 - 10
  • [9] Assessment of global cardiac I-123 MIBG uptake and washout using volumetric quantification of SPECT acquisitions
    van der Veen, Berlinda J.
    Al Younis, Imad
    de Roos, Albert
    Stokkel, Marcel P. M.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (04) : 752 - 762
  • [10] Comparison of ejection fraction calculation between CT and SPECT at high heart rate: A dynamic cardiac phantom study
    Chen, Chien-Cheng
    Shen, Thau-Yun
    Peterson, Christine B.
    Hung, Guang-Uei
    Pan, Tinsu
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (01) : 311 - 316