Effect of Low Temperature on Electrical Treeing of Polypropylene with Repetitive Pulse Voltage

被引:18
作者
Du, B. X. [1 ]
Zhu, L. W. [1 ]
Han, T. [1 ]
机构
[1] Tianjin Univ, Sch Elect Engn & Automat, Educ Minist, Key Lab Smart Grid, Tianjin 300072, Peoples R China
关键词
HVDC cable; PP; XLPE; electrical tree; repetitive pulse voltage; pulse frequency; pulse amplitude; low temperature; tree length; fractal dimension; tree inception; XLPE CABLE INSULATION; FRACTAL ANALYSIS; EPOXY-RESIN; INITIATION; DC; POLYETHYLENE; FREQUENCY;
D O I
10.1109/TDEI.2016.7556462
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Polypropylene (PP) has been considered as an alternation to cross-linked polyethylene (XLPE) using as the high voltage direct current (HVDC) cable insulation material due to its no crosslinking process and environment friendly characteristics. During the operation, repetitive pulse voltage may generate in HVDC cable system and the challenge of the low temperature environment may occur. This paper compares the tree characteristics of PP and XLPE with the pulse voltage of 12 kV and 400 Hz under low temperature. Furthermore, the influence of pulse amplitude and frequency on the electrical trees of PP under low temperature is investigated. The frequencies of pulse voltage were 400, 800 and 1200 Hz and the pulse amplitudes were 12 and 15 kV. The experimental temperature from 30 to -196 degrees C was applied in the test. The results show that compared with the XLPE, the electrical tree is more difficult to be generated in the PP. The growth rate and fractal dimension of tree in the PP are smaller than these in the XLPE with the same treeing time. The low temperature, pulse frequency and amplitude have an influence on the treeing process. It is obtained that the growth of electrical tree is resisted under the low temperature. The higher pulse frequency accelerates the tree propagation process. The higher amplitude accelerates the tree growth rate and fractal dimension at -30 and -196 degrees C. However, the tree propagation process is not accelerated by the higher amplitude at -90 degrees C.
引用
收藏
页码:1915 / 1923
页数:9
相关论文
共 38 条
[1]  
Campus A, 2002, 2002 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, P155, DOI 10.1109/CEIDP.2002.1048759
[2]   PD inference for the early detection of electrical treeing in insulation systems [J].
Cavallini, A ;
Conti, M ;
Montanari, GC ;
Arlotti, C ;
Contin, A .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2004, 11 (04) :724-735
[3]   Electrical Treeing Characteristics in XLPE Power Cable Insulation in Frequency Range between 20 and 500 Hz [J].
Chen, G. ;
Tham, C. H. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2009, 16 (01) :179-188
[4]   Review of High Voltage Direct Current Cables [J].
Chen, George ;
Hao, Miao ;
Xu, Zhiqiang ;
Vaughan, Alun ;
Cao, Junzheng ;
Wang, Haitian .
CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2015, 1 (02) :9-21
[5]  
Chen J., 2010, J APPL PHYS, V43, P1
[6]   Effect of Tree Channel Conductivity on Electrical Tree Shape and Breakdown in XLPE Cable Insulation Samples [J].
Chen, Xiangrong ;
Xu, Yang ;
Cao, Xiaolong ;
Dodd, S. J. ;
Dissado, L. A. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (03) :847-860
[7]   Nanocomposites-A Review of Electrical Treeing and Breakdown [J].
Danikas, Michael G. ;
Tanaka, Toshikatsu .
IEEE ELECTRICAL INSULATION MAGAZINE, 2009, 25 (04) :19-25
[8]   Effect of Low Temperature on Tree Characteristics in Silicone Rubber with Different Power Frequency [J].
Du, B. X. ;
Han, T. ;
Su, J. G. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (04) :1680-1686
[9]   Effect of Pulse Frequency on Tree Characteristics in Epoxy Resin under Low Temperature [J].
Du, B. X. ;
Zhang, M. M. ;
Han, T. ;
Zhu, L. W. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (01) :104-112
[10]   Electrical Tree Characteristics of XLPE under Repetitive Pulse Voltage in Low Temperature [J].
Du, B. X. ;
Zhu, L. W. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (04) :1801-1808