The Application of Software "Rapid Processing of Perfusion and Diffusion" in Acute Ischemic Stroke

被引:9
作者
Zhang, Yudi [1 ]
Song, Shuang [1 ]
Li, Zhenzhong [1 ]
Huang, Boyuan [2 ]
Geng, Yanlu [1 ,3 ]
Zhang, Lihong [1 ]
机构
[1] Hebei Med Univ, Dept Neurol, Hosp 2, Shijiazhuang 050000, Hebei, Peoples R China
[2] Hebei Med Univ, Dept Radiol, Hosp 2, Shijiazhuang 050000, Hebei, Peoples R China
[3] Cent Hosp Qinghe Cty, Dept Neurol, Xingtai 054800, Peoples R China
关键词
RAPID software; PWI; CTP; acute ischemic stroke; HIGH-RESOLUTION MEASUREMENT; TRACER BOLUS PASSAGES; IMAGING EVALUATION; NEUROLOGICAL DEFICITS; INFARCT VOLUME; DL-3-N-BUTYLPHTHALIDE; THROMBECTOMY; REPERFUSION; THERAPY; TRIAL;
D O I
10.3390/brainsci12111451
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
In the event of an acute ischemic stroke, saving the penumbra is the most important aspect of early treatment. The rapid and accurate identification of ischemic penumbra plays a key role in its comprehensive treatment. At present, the identification method and evaluation standard of ischemic penumbra have not been unified. Numerous pieces of software identifying ischemic penumbra have been developed, such as rapid processing of perfusion and diffusion (RAPID), Sphere, Vitrea, and computed tomography perfusion+ (CTP+). The RAPID software, analyzing and integrating multi-mode image data (mainly based on perfusion weighted imaging (PWI) or computed tomography perfusion (CTP) images, shows good performance in identifying ischemic penumbra and has been utilized for the assessment of ischemic penumbra in many ischemic stroke clinical studies, achieving good outcomes and promoting the transition from "time window" to "tissue window" in the treatment of early stage AIS. To obtain a comprehensive understanding of the RAPID software and its accuracy in evaluating ischemic penumbra, this paper reviews the background and development of the RAPID software, summarizes the published acute cerebral infarction trials using the RAPID software, generalizes the threshold parameters in different time windows, and further discusses its application and limitations.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Two-way comparison of brain perfusion image processing software for patients with acute ischemic strokes in real-world
    Cai, Heng
    Fan, Shengyu
    Bian, Yueyan
    Yang, Qi
    Long, Zhenhai
    Chen, Liangyu
    Tang, Wei
    Zhang, Nan
    Zhen, Yongyu
    Li, Zhiqing
    NEURORADIOLOGY, 2022, 64 (01) : 161 - 169
  • [22] Predictors of Infarct Growth Measured by Apparent Diffusion Coefficient Quantification in Patients with Acute Ischemic Stroke
    Deng, Wenjing
    Teng, Junfang
    Liebeskind, David
    Miao, Wang
    Du, Ran
    WORLD NEUROSURGERY, 2019, 123 : E797 - E802
  • [23] Comparison of two computed tomography perfusion post-processing software to assess infarct volume in patients with acute ischemic stroke
    Liu, Jiayang
    Wang, Jingjie
    Wu, Jiajing
    Gu, Sirun
    Yao, Yunzhuo
    Li, Jing
    Li, Yongmei
    Ren, Huanhuan
    Luo, Tianyou
    FRONTIERS IN NEUROSCIENCE, 2023, 17
  • [24] Endovascular Treatment of Acute Ischemic Stroke
    Kidwell, Chelsea S.
    Jahan, Reza
    NEUROLOGIC CLINICS, 2015, 33 (02) : 401 - +
  • [25] Evolution pattern estimated by computed tomography perfusion post-thrombectomy predicts outcome in acute ischemic stroke
    Dai, Xinyu
    Yan, Chuming
    Yu, Fan
    Li, Qiuxuan
    Lu, Yao
    Shan, Yi
    Zhang, Miao
    Guo, Daode
    Bai, Xuesong
    Jiao, Liqun
    Ma, Qingfeng
    Lu, Jie
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2024, 33 (04)
  • [26] Perfusion Computed Tomography in Acute Ischemic Stroke
    Heit, Jeremy J.
    Sussman, Eric S.
    Wintermark, Max
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2019, 57 (06) : 1109 - +
  • [27] Evaluation of Siemens Healthineers' StrokeSegApp for automated diffusion and perfusion lesion segmentation in patients with ischemic stroke
    Teichmann, Lynnet-Samuel J.
    Khalil, Ahmed A.
    Villringer, Kersten
    Fiebach, Jochen B.
    Huwer, Stefan
    Gibson, Eli
    Galinovic, Ivana
    FRONTIERS IN NEUROLOGY, 2025, 16
  • [28] Volumetric and Spatial Accuracy of Computed Tomography Perfusion Estimated Ischemic Core Volume in Patients With Acute Ischemic Stroke
    Hoving, Jan W.
    Marquering, Henk A.
    Majoie, Charles B. L. M.
    Yassi, Nawaf
    Sharma, Gagan
    Liebeskind, David S.
    van der Lugt, Aad
    Roos, Yvo B.
    van Zwam, Wim
    van Oostenbrugge, Robert J.
    Goyal, Mayank
    Saver, Jeffrey L.
    Jovin, Tudor G.
    Albers, Gregory W.
    Davalos, Antoni
    Hill, Michael D.
    Demchuk, Andrew M.
    Bracard, Serge
    Guillemin, Francis
    Muir, Keith W.
    White, Philip
    Mitchell, Peter J.
    Donnan, Geoffrey A.
    Davis, Stephen M.
    Campbell, Bruce C. V.
    STROKE, 2018, 49 (10) : 2368 - 2375
  • [29] Validation of a novel CT perfusion software compared to RAPID in stroke patients receiving endovascular therapy
    Chen, Dan
    Chen, Wenhuo
    Nguyen, Thanh N.
    Yi, Tingyu
    Zhang, Luyun
    Guo, Xinze
    Chang, Yanting
    Bai, Xue
    Deng, Bowen
    Zhang, Yang
    Zhao, Yang
    Qiu, Tingting
    Wang, Yu
    Sui, Yi
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [30] Safety and Time Course of Drip-and-Ship in Treatment of Acute Ischemic Stroke
    Ishihara, Hideyuki
    Oka, Fumiaki
    Oku, Takayuki
    Shinoyama, Mizuya
    Suehiro, Eiichi
    Sugimoto, Kazutaka
    Suzuki, Michiyasu
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2017, 26 (11) : 2477 - 2481