The Application of Software "Rapid Processing of Perfusion and Diffusion" in Acute Ischemic Stroke

被引:9
|
作者
Zhang, Yudi [1 ]
Song, Shuang [1 ]
Li, Zhenzhong [1 ]
Huang, Boyuan [2 ]
Geng, Yanlu [1 ,3 ]
Zhang, Lihong [1 ]
机构
[1] Hebei Med Univ, Dept Neurol, Hosp 2, Shijiazhuang 050000, Hebei, Peoples R China
[2] Hebei Med Univ, Dept Radiol, Hosp 2, Shijiazhuang 050000, Hebei, Peoples R China
[3] Cent Hosp Qinghe Cty, Dept Neurol, Xingtai 054800, Peoples R China
关键词
RAPID software; PWI; CTP; acute ischemic stroke; HIGH-RESOLUTION MEASUREMENT; TRACER BOLUS PASSAGES; IMAGING EVALUATION; NEUROLOGICAL DEFICITS; INFARCT VOLUME; DL-3-N-BUTYLPHTHALIDE; THROMBECTOMY; REPERFUSION; THERAPY; TRIAL;
D O I
10.3390/brainsci12111451
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
In the event of an acute ischemic stroke, saving the penumbra is the most important aspect of early treatment. The rapid and accurate identification of ischemic penumbra plays a key role in its comprehensive treatment. At present, the identification method and evaluation standard of ischemic penumbra have not been unified. Numerous pieces of software identifying ischemic penumbra have been developed, such as rapid processing of perfusion and diffusion (RAPID), Sphere, Vitrea, and computed tomography perfusion+ (CTP+). The RAPID software, analyzing and integrating multi-mode image data (mainly based on perfusion weighted imaging (PWI) or computed tomography perfusion (CTP) images, shows good performance in identifying ischemic penumbra and has been utilized for the assessment of ischemic penumbra in many ischemic stroke clinical studies, achieving good outcomes and promoting the transition from "time window" to "tissue window" in the treatment of early stage AIS. To obtain a comprehensive understanding of the RAPID software and its accuracy in evaluating ischemic penumbra, this paper reviews the background and development of the RAPID software, summarizes the published acute cerebral infarction trials using the RAPID software, generalizes the threshold parameters in different time windows, and further discusses its application and limitations.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Prognostic Prediction Model for Endovascular Treatment of Acute Anterior Circulation Ischemic Stroke Based on Rapid Processing of PerfusIon and Diffusion Software
    Shen, Yuan
    Xu, Gang
    Shi, Haicun
    Wang, Shufang
    Zhou, Li
    Zhong, Jianguo
    Chen, Mingzhu
    Chen, Zhipeng
    Dong, Zhifeng
    WORLD NEUROSURGERY, 2025, 194
  • [2] Utility of automated CT perfusion software in acute ischemic stroke with large and medium vessel occlusion
    Ahmadabad, Rezan Ashayeri
    Tran, Kim H.
    Zhang, Yiran
    Kate, Mahesh P.
    Mishra, Sachin
    Buck, Brian H.
    Khan, Khurshid A.
    Rempel, Jeremy
    Albers, Gregory W.
    Shuaib, Ashfaq
    ANNALS OF CLINICAL AND TRANSLATIONAL NEUROLOGY, 2024, 11 (11): : 2967 - 2976
  • [3] Agreement of three CT perfusion software packages in patients with acute ischemic stroke: A comparison with RAPID
    Lu, Qingqing
    Fu, Junyan
    Lv, Kun
    Han, Yan
    Pan, Yuning
    Xu, Yiren
    Zhang, Jun
    Geng, Daoying
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 156
  • [4] Clinical application of perfusion and diffusion MR imaging in acute ischemic stroke
    Ueda, T
    Yuh, WTC
    Taoka, T
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (03) : 305 - 309
  • [5] Computed Tomography Perfusion Data for Acute Ischemic Stroke Evaluation Using Rapid Software: Pitfalls of Automated Postprocessing
    Kauw, Frans
    Heit, Jeremy J.
    Martin, Blake W.
    van Ommen, Fasco
    Kappelle, L. Jaap
    Velthuis, Birgitta K.
    de Jong, Hugo W. A. M.
    Dankbaar, Jan W.
    Wintermark, Max
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (01) : 75 - 77
  • [6] Comparison of 3 CT Perfusion Software Packages in Estimation of Ischemic Lesions in Acute Ischemic Stroke Patients
    Li, Xiang
    Zeng, Chen
    Li, Yige
    Liu, Huan
    Liu, Ling
    Zeng, Wenbing
    Yang, Ran
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2023, 47 (03) : 500 - 506
  • [7] Rapid Processing of Perfusion and Diffusion for Ischemic Strokes in the Extended Time Window: An Indian Experience
    Vyas, Devashish
    Bohra, Vikram
    Karan, Vivek
    Huded, Vikram
    ANNALS OF INDIAN ACADEMY OF NEUROLOGY, 2019, 22 (01) : 96 - 99
  • [8] Advances in cerebral perfusion imaging techniques in acute ischemic stroke
    Fang, Hui
    He, Guangchen
    Cheng, Yingsheng
    Liang, Fuyou
    Zhu, Yueqi
    JOURNAL OF CLINICAL ULTRASOUND, 2022, 50 (08) : 1202 - 1211
  • [9] Patchy profile sign in RAPID software: a specific marker for intracranial atherosclerotic stenosis in acute ischemic stroke
    Zhang, Lingwen
    Xue, Hua
    Bu, Xiaoqing
    Liao, Juan
    Tang, Ge
    Chen, Yu
    Zhao, Libo
    Yang, Deyu
    Liu, Li
    Liu, Shudong
    FRONTIERS IN NEUROLOGY, 2024, 15
  • [10] Agreement and Accuracy of Ischemic Core Volume Evaluated by Three CT Perfusion Software Packages in Acute Ischemic Stroke
    Liu, Qin Chen
    Jia, Zhen Yu
    Zhao, Lin Bo
    Cao, Yue Zhou
    Ma, Gao
    Shi, Hai Bin
    Liu, Sheng
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2021, 30 (08)