EGSnrc Monte Carlo calculated dosimetry parameters for 192Ir and 169Yb brachytherapy sources

被引:108
作者
Taylor, R. E. P. [1 ]
Rogers, D. W. O. [1 ]
机构
[1] Carleton Univ, Carleton Lab Radiotherapy Phys, Ottawa Carleton Inst Phys, Ottawa, ON K1S 5B6, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
brachytherapy; Ir-192; Yb-169; EGSnrc; Monte Carlo; primary scatter separated dose; database; high dose rate; pulsed dose rate;
D O I
10.1118/1.2987676
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study presents the results of EGSnrc Monte Carlo calculations of the dose distribution surrounding a high dose rate Yb-169 brachytherapy source and 14 high dose rate and pulsed dose rate Ir-192 brachytherapy sources. Energy-weighted spectra of emitted photons, a full set of TG-43 dosimetry parameters, along-away dose tables, and a description of the materials and geometry used for each source are provided. In addition to this, separate tallies are made of the dose contributed from primary, single-scattered, and multiply-scattered photons. Separation of dose in this manner allows one to use convolution/superposition methods to calculate the dose surrounding a brachytherapy source accounting for a non-homogeneous medium. The effect of phantom size on TG-43 dosimetry parameters and scattered dose is also investigated for the Ir-192 microSelectron v2 HDR source. This paper describes the calculation methods and presents the dose rate constants calculated for each source with the full set of dosimetry data being available online at the Carleton Laboratory for Radiotherapy Physics brachytherapy database (http://www.physics.carleton.ca/clrp/seed_database/). (C) 2008 American Association of Physicists in Medicine. [DOI: 10.1118/1.2987676]
引用
收藏
页码:4933 / 4944
页数:12
相关论文
共 50 条
  • [1] Monte Carlo dosimetry of a new 192Ir high dose rate brachytherapy source
    Angelopoulos, A
    Baras, P
    Sakelliou, L
    Karaiskos, P
    Sandilos, P
    [J]. MEDICAL PHYSICS, 2000, 27 (11) : 2521 - 2527
  • [2] [Anonymous], 1987, NBSIR873597 NIST
  • [3] Technical note:: Monte-Carlo dosimetry of the HDR 12i and plus 192Ir sources (vol 28, pg 2586, 2001)
    Ballester, F
    Puchades, V
    Pérez-Calatayud, J
    Casal, E
    [J]. MEDICAL PHYSICS, 2004, 31 (08) : 2372 - 2372
  • [4] Monte Carlo calculation of dose rate distributions around Ir-192 wires
    Ballester, F
    Hernandez, C
    PerezCalatayud, J
    Lliso, F
    [J]. MEDICAL PHYSICS, 1997, 24 (08) : 1221 - 1228
  • [5] Technical note:: Monte-Carlo dosimetry of the HDR 12i and plus 192Ir sources
    Ballester, F
    Puchades, V
    Lluch, JL
    Serrano-Andrés, MA
    Limami, Y
    Pérez-Calatayud, J
    Casal, E
    [J]. MEDICAL PHYSICS, 2001, 28 (12) : 2586 - 2591
  • [6] Monte Carlo dosimetry of the Buchler high dose rate 192Ir source
    Ballester, F
    Pérez-Calatayud, J
    Puchades, V
    Lluch, JL
    Serrano-Andrés, MA
    Limami, Y
    Lliso, F
    Casal, E
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (03) : N79 - N90
  • [7] Beta versus gamma dosimetry close to Ir-192 brachytherapy sources
    Baltas, D
    Karaiskos, P
    Papagiannis, P
    Sakelliou, L
    Loeffler, E
    Zamboglou, N
    [J]. MEDICAL PHYSICS, 2001, 28 (09) : 1875 - 1882
  • [8] Spectra and air-kerma strength for encapsulated 192Ir sources
    Borg, J
    Rogers, DWO
    [J]. MEDICAL PHYSICS, 1999, 26 (11) : 2441 - 2444
  • [9] The collapsed cone superposition algorithm applied to scatter dose calculations in brachytherapy
    Carlsson, ÅK
    Ahnesjö, A
    [J]. MEDICAL PHYSICS, 2000, 27 (10) : 2320 - 2332
  • [10] Point kernels and superposition methods for scatter dose calculations in brachytherapy
    Carlsson, ÅK
    Ahnesjö, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (02) : 357 - 382