Evaluation of the water equivalence of solid phantoms using gamma ray transmission measurements

被引:75
作者
Hill, R. F. [1 ,2 ]
Brown, S. [2 ,3 ]
Baldock, C. [2 ]
机构
[1] Royal Prince Alfred Hosp, Dept Radiat Oncol, Camperdown, NSW 2050, Australia
[2] Univ Sydney, Inst Med Phys, Sch Phys, Sydney, NSW 2006, Australia
[3] Royal N Share Hosp, Dept Radiat Oncol, Sydney, NSW, Australia
关键词
Solid phantoms; Water equivalency; Technetium-99m; EGSnrc Monte Carlo; XCOM; Low energy photons;
D O I
10.1016/j.radmeas.2008.01.019
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Gamma ray transmission measurements have been used to evaluate the water equivalence of solid phantoms. Technetium-99m was used in narrow beam geometry and the transmission of photons measured, using a gamma camera, through varying thickness of the solid phantom material and water. Measured transmission values were compared with Monte Carlo calculated transmission data using the EGSnrc Monte Carlo code to score fluence in a geometry similar to that of the measurements. The results indicate that the RM1457 Solid Water, CMNC Plastic Water and PTW RW3 solid phantoms had similar transmission values as compared to water to within +/- 1.5%. However, Perspex had a greater deviation in the transmission values up to +/- 4%. The agreement between the measured and EGSnrc calculated transmission values agreed to within 1% over the range of phantom thickness studied. ne linear attenuation coefficients at the gamma ray energy of 140.5 keV were determined from the measured and EGSnrc: calculated transmission data and compared with predicted values derived from data provided by the National Institute of Standards and Technology (NIST) using the XCOM program. The coefficients derived from the measured data were up to 6% lower than those predicted by the XCOM program, while the coefficients determined from the Monte Carlo calculations were between measured and XCOM values. The results indicate that a similar process can be followed to determine the water equivalency of other solid phantoms and at other photon energies. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1258 / 1264
页数:7
相关论文
共 24 条
  • [1] An evaluation of epoxy resin phantom materials for megavoltage photon dosimetry
    Allahverdi, M
    Nisbet, A
    Thwaites, DI
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (05) : 1125 - 1132
  • [2] Andreo P, 2000, TECHNICAL REPORT SER, V398
  • [3] [Anonymous], 1998, XCOM PHOTON CROSS SE
  • [4] Response of a tissue equivalent proportional counter to neutrons
    Badhwar, GD
    Robbins, DE
    Gibbons, F
    Braby, LA
    [J]. RADIATION MEASUREMENTS, 2002, 35 (06) : 551 - 556
  • [5] BROWN S, 2005, AUSTRALAS PHYS ENG S, V29, P140
  • [6] Chu S.Y. F., 1999, Table of radioactive isotopes
  • [7] The effect of pull back technique on dose distribution in the junction region for 90Sr/90Y intravascular brachytherapy sources
    Demir, B
    Bilge, H
    Dincbas, FO
    Koca, A
    Karacam, S
    Gunhan, B
    [J]. RADIATION MEASUREMENTS, 2005, 39 (01) : 29 - 32
  • [8] Output factor measurements for a kilovoltage x-ray therapy unit
    Healy B.J.
    Gibbs A.
    Murry R.L.
    Prunster J.E.
    Nitschke K.N.
    [J]. Australasian Physics & Engineering Sciences in Medicine, 2005, 28 (2): : 115 - 121
  • [9] POLYETHYLENE-BASED WATER-EQUIVALENT PHANTOM MATERIAL FOR X-RAY DOSIMETRY AT TUBE VOLTAGES FROM 10 TO 100 KV
    HERMANN, KP
    GEWORSKI, L
    MUTH, M
    HARDER, D
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (11) : 1195 - 1200
  • [10] A dosimetric evaluation of water equivalent phantoms for kilovoltage x-ray beams
    Hill, R
    Holloway, L
    Baldock, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (21) : N331 - N344