Selecting the diameter of a radial head implant: an assessment of local landmarks

被引:15
作者
Alolabi, Bashar [1 ]
Studer, Alexis [2 ]
Gray, Alia [3 ]
Ferreira, Louis M. [3 ,4 ]
King, Graham J. W. [3 ,4 ]
Johnson, James A. [3 ,4 ]
Athwal, George S. [3 ,4 ]
机构
[1] Cleveland Clin Fdn, Orthoped & Rheumatol Inst, Cleveland, OH 44195 USA
[2] Alps Surg Inst, Annecy, France
[3] Western Univ, Dept Surg, London, ON, Canada
[4] St Josephs Hlth Care, Hand & Upper Limb Ctr, London, ON, Canada
关键词
Radial head replacement; lesser sigmoid notch; diameter; sizing; ARTHROPLASTY; REPLACEMENT; PROSTHESIS; ELBOW; SIZE;
D O I
10.1016/j.jse.2013.04.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Little information exists on radial head implant diameter sizing methods. When the native head is absent due to extensive comminution or previous excision, the lesser sigmoid notch may be a useful landmark for sizing. We evaluated the reliability of native radial head measurements, and the lesser sigmoid notch, as landmarks for radial head implant diameter sizing. Methods: We examined 27 fresh frozen ulnae and their corresponding radial heads. The maximum, minimum, and dish diameters of the radial heads were measured. A radial head implant diameter was selected based on the congruency of the trial implants with the radius of curvature of the lesser sigmoid notch. Intraobserver and interobserver reliability for all measurements and implant selection were assessed using intraclass correlation coefficients (ICC). Correlations between the native radial head measurements and the selected radial head implant diameter or the lesser sigmoid notch radius of curvature were assessed using the Pearson correlation coefficient (PCC). Results: Radial head diameter measurements demonstrated strong to excellent intraobserver (ICC >= 0.75) and interobserver reliability (ICC >= 0.82). The lesser sigmoid notch sizing method showed poor interobserver reliability (ICC = 0.34). Only a moderate correlation was found between the native radial head and the lesser sigmoid notch (PCC <= 0.80) or the selected radial head implant size (PCC <= 0.59). Conclusion: Radial head diameter measurements showed excellent reliability, suggesting that the excised radial head, when available, should be used to select the implant diameter. The reliability of using the lesser sigmoid notch for sizing the diameter of radial head implants was only moderate, suggesting this is an unreliable landmark for implant diameter sizing. Level of evidence: Basic Science Study, Anatomy, Cadaver Dissection. (C) 2013 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:1395 / 1399
页数:5
相关论文
共 12 条
[1]  
Athwal GS, 2011, J BONE JOINT SURG AM, V93A, P1339, DOI [10.2106/JBJS.J.01244, 10.2106/JBJSJ.01244]
[2]   Loss of flexion after radial head replacement [J].
Birkedal, JP ;
Deal, DN ;
Ruch, DS .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2004, 13 (02) :208-213
[3]   Reference points for radial head prosthesis size [J].
Doornberg, JN ;
Linzel, DS ;
Zurakowski, D ;
Ring, D .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (01) :53-57
[4]   Radial head arthroplasty with a modular metal spacer to treat acute traumatic elbow instability [J].
Doornberg, Job N. ;
Parisien, Robert ;
van Duijn, P. Joppe ;
Ring, David .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (05) :1075-1080
[5]   Determination of Correct Implant Size in Radial Head Arthroplasty to Avoid Overlengthening [J].
Frank, Simon G. ;
Grewal, Ruby ;
Johnson, James ;
Faber, Kenneth J. ;
King, Graham J. W. ;
Athwal, George S. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (07) :1738-1746
[6]   Comminuted radial head fractures treated with a modular metallic radial head arthroplasty - Study of outcomes [J].
Grewal, Ruby ;
MacDermid, Joy C. ;
Faber, Kenneth J. ;
Drosdowech, Darren S. ;
King, Graham J. W. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (10) :2192-2200
[7]  
Pugh David M W, 2002, Tech Hand Up Extrem Surg, V6, P21, DOI 10.1097/00130911-200203000-00005
[8]  
Ring David, 2008, J Bone Joint Surg Am, V90 Suppl 2 Pt 1, P63, DOI 10.2106/JBJS.G.01248
[9]   The kinematic importance of radial neck length in radial head replacement [J].
Van Glabbeek, F ;
van Riet, RP ;
Baumfeld, JA ;
Neale, PG ;
O'Driscoll, SW ;
Morrey, BF ;
An, KN .
MEDICAL ENGINEERING & PHYSICS, 2005, 27 (04) :336-342
[10]   Detrimental effects of overstuffing or understuffing with a radial head replacement in the medial collater-alligament deficient elbow [J].
Van Glabbeek, F ;
van Riet, RR ;
Baumfeld, JA ;
Neale, PG ;
O'Driscoll, SW ;
Morrey, BF ;
An, KN .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (12) :2629-2635