Poly(pyrrole) versus poly(3,4-ethylenedioxythiophene): amperometric cholesterol biosensor matrices

被引:17
作者
Tuerkarslan, Oezlem [1 ]
Kayahan, Senem Kiralp [1 ]
Toppare, Levent [1 ]
机构
[1] Middle E Tech Univ, Dept Chem, TR-06531 Ankara, Turkey
关键词
Amperometric biosensor; Enzyme electrodes; Conducting polymers; Cholesterol; Cholesterol oxidase; SELF-ASSEMBLED MONOLAYER; POLY 3,4-ETHYLENEDIOXYTHIOPHENE; OXIDASE; SURFACE; FILM; POLYPYRROLE; ELECTROPOLYMERIZATION; IMMOBILIZATION; ELECTRODE; ESTERASE;
D O I
10.1007/s10008-008-0590-7
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Two conducting polymers, poly(pyrrole) (PPy) and poly(3,4-ethylenedioxythiophene) (PEDOT) were used as immobilization matrices for cholesterol oxidase (ChOx). The amperometric responses of the enzyme electrodes were measured by monitoring oxidation current of H2O2 at +0.7 V in the absence of a mediator. Kinetic parameters, such as K (m) and I (max), operational and storage stabilities, effects of pH and temperature were determined for both entrapment supports. K (m) values are found as 7.9 and 1.3 mM for PPy and PEDOT enzyme electrodes, respectively; it can be interpreted that ChOx immobilized in PEDOT shows higher affinity towards the substrate.
引用
收藏
页码:657 / 663
页数:7
相关论文
共 43 条
  • [1] ALLAIN CC, 1974, CLIN CHEM, V20, P470
  • [2] Multicolored electrochromism polymers: Structures and devices
    Argun, AA
    Aubert, PH
    Thompson, BC
    Schwendeman, I
    Gaupp, CL
    Hwang, J
    Pinto, NJ
    Tanner, DB
    MacDiarmid, AG
    Reynolds, JR
    [J]. CHEMISTRY OF MATERIALS, 2004, 16 (23) : 4401 - 4412
  • [3] Novel conducting polymer electrolyte biosensor based on poly(1-vinyl imidazole) and poly(acrylic acid) networks
    Arslan, A
    Kiralp, S
    Toppare, L
    Bozkurt, A
    [J]. LANGMUIR, 2006, 22 (06) : 2912 - 2915
  • [4] Cholesterol biosensor based on N-(2-aminoethyl)-3-aminopropyl-trimethoxysilane self-assembled monolayer
    Arya, Sunil K.
    Prusty, Arun K.
    Singh, S. P.
    Solanki, Pratima R.
    Pandey, Manoj K.
    Datta, Monika
    Malhotra, Bansi D.
    [J]. ANALYTICAL BIOCHEMISTRY, 2007, 363 (02) : 210 - 218
  • [5] Poly-(3-hexylthiophene) self-assembled monolayer based cholesterol biosensor using surface plasmon resonance technique
    Arya, Sunil K.
    Solanki, Pratima R.
    Singh, S. P.
    Kaneto, K.
    Pandey, Manoj K.
    Datta, Monika
    Malhotra, Bansi D.
    [J]. BIOSENSORS & BIOELECTRONICS, 2007, 22 (11) : 2516 - 2524
  • [6] Application of octadecanethiol self-assembled monolayer to cholesterol biosensor based on surface plasmon resonance technique
    Arya, Sunil K.
    Solanki, Pratima R.
    Singh, Ravindra P.
    Pandey, Manoj K.
    Datta, Monika
    Malhotra, Bansi D.
    [J]. TALANTA, 2006, 69 (04) : 918 - 926
  • [7] Electrochemical sensors
    Bakker, Eric
    Qin, Yu
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (12) : 3965 - 3983
  • [8] Amperometric determination of cholesterol in serum using a biosensor of cholesterol oxidase contained within a polypyrrole-hydrogel membrane
    Brahim, S
    Narinesingh, D
    Guiseppi-Elie, A
    [J]. ANALYTICA CHIMICA ACTA, 2001, 448 (1-2) : 27 - 36
  • [9] Polyethylene-co-acrylic acid as coating for biosensor application:: A quartz crystal microbalance study
    Chong, KT
    Su, XD
    Lee, EJD
    O'Shea, SJ
    [J]. LANGMUIR, 2002, 18 (25) : 9932 - 9936
  • [10] Immobilization of cholesterol oxidase in a conducting copolymer of thiophene-3-yl acetic acid cholesteryl ester with pyrrole
    Çirpan, A
    Alkan, S
    Toppare, L
    Cianga, I
    Yagci, Y
    [J]. DESIGNED MONOMERS AND POLYMERS, 2003, 6 (03) : 237 - 243