Automatic Detection of Small Bowel Contraction Frequencies in Motility Plots Using Lomb-Scargle Periodogram and Sinus-Fitting Method-Initial Experience

被引:15
作者
Bickelhaupt, Sebastian [1 ]
Cattin, Roger [2 ]
Froehlich, Johannes M. [1 ]
Raible, Stephan [2 ]
Bouquet, Hanspeter [3 ]
Bill, Urs [3 ]
Patak, Michael A. [1 ]
机构
[1] Univ Zurich Hosp, Dept Radiol, CH-8091 Zurich, Switzerland
[2] Univ Appl Sci, CH-2501 Biel, Switzerland
[3] SOHARD AG, CH-3006 Bern, Switzerland
关键词
small bowel motility; lomb scargle periodograms; sinus fitting method; software-assisted analysis; automatic detection; SPACED DATA; MRI;
D O I
10.1002/mrm.24708
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeContraction frequencies are an important parameter for the analysis of bowel motility in MRI. The contraction curve can be rather noisy and the frequency-evaluation might be difficult. The aim was to evaluate manual calculations of small bowel contraction frequency in comparison with automatic calculations using two mathematically established methods. MethodsThe institutional-review-board approved study consisted of 48 segmental small-bowel motility-plots out of a previous study with 25 patients (15 men/10 women; mean 39 years, standard deviation14.67) undergoing MRI (1.5 T, GE-Medical Systems; two-dimensional-Fiesta, pulse repetition time 2.91, echo time 1.25, flip-angle 45 degrees, matrix 256 x 256, slice thickness 10 mm) were evaluated. Calculations of contraction frequency was performed either manually or using Lomb-Scargle-periodograms and Sinus-Fitting method. The results were compared using intraclass correlation coefficient, Friedman's-test and Wilcoxon-matched-paired-signed-rank-test (P<0.05 considered statistically significant). ResultsMean contraction frequency was 5.69 (standard deviation +/- 1.99) for manual calculations showing moderate interreader reliability (intraclass correlation coefficient 0.72; 95% confidence-interval: 0.59;0.82). No significant difference (P=0.776) was found to Lomb-Scargle-periodograms (5.34 contractions-per-minute [cpm], standard deviation +/- 2.47; P=0.174) and to the sinus-fitting-method (5.47 cpm; standard deviation +/- 2.57; P=0.0779). For the latter calculations failed in 3/48 plots, while manual and Lomb-Scargle-periodograms could be performed successfully in all 48/48 plots. ConclusionHerein, we could show that Lomb-Scargle-periodograms and Sinus-Fitting are fast and reliable methods to automatically measure small-bowel contraction frequencies even in noisy small bowel motility plots. Magn Reson Med 71:628-634, 2014. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:628 / 634
页数:7
相关论文
共 20 条
[1]  
[Anonymous], 1994, IEEE STAND DIG WAV R
[2]  
Bickelhaupt S, 2012, P ESGAR 2012, V3, P455
[3]  
Bickelhaupt S, 2012, RSNA
[4]  
Bickelhaupt S, 2012, INSIGHTS IMAGING, V3, P455
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]   Small bowel motility assessment with magnetic resonance imaging [J].
Froehlich, JM ;
Patak, MA ;
von Weymarn, C ;
Juli, CF ;
Zollikofer, CL ;
Wentz, KU .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (04) :370-375
[8]   MR motility imaging in Crohn's disease improves lesion detection compared with standard MR imaging [J].
Froehlich, Johannes M. ;
Waldherr, Christian ;
Stoupis, Christoforos ;
Erturk, S. Mehmet ;
Patak, Michael A. .
EUROPEAN RADIOLOGY, 2010, 20 (08) :1945-1951
[9]   Evaluation of the anti-peristaltic effect of glucagon and hyoscine on the small bowel: comparison of intravenous and intramuscular drug administration [J].
Gutzeit, Andreas ;
Binkert, Christoph A. ;
Koh, Dow-Mu ;
Hergan, Klaus ;
von Weymarn, Constantin ;
Graf, Nicole ;
Patak, Michael A. ;
Roos, Justus E. ;
Horstmann, Marcus ;
Kos, Sebastian ;
Hungerbuehler, Simone ;
Froehlich, Johannes M. .
EUROPEAN RADIOLOGY, 2012, 22 (06) :1186-1194
[10]  
Handel P., 2000, IEEE T INSTRUMENTATI, V49, P6