Fatigue behavior of Ti50Zr alloy for dental implant application

被引:12
作者
Cui, Wenfang [1 ]
Liu, Yaohui [1 ]
机构
[1] Northeastern Univ, Key Lab Anisotropy & Texture Mat, Minist Educ, Sch Mat Sci & Engn, Shenyang 110819, Liaoning, Peoples R China
基金
中国国家自然科学基金;
关键词
Titanium alloys; Dental implant; Microstructure; Fatigue; MECHANICAL-PROPERTIES; TITANIUM; MICROSTRUCTURE; STRENGTH;
D O I
10.1016/j.jallcom.2019.04.165
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The microstructure, tensile and fatigue behavior of a hot-rolled Ti50Zr alloy applied for dental implant were investigated. The commercial Ti16Zr alloy was taken as a reference material. The load vs. number of cycling curves of the one-piece type Ti16Zr and Ti50Zr dental implants were tested according to ISO 14801 standard testing methods. The results show that the yield strength and fatigue limit of Ti50Zr alloy are up to 1001 +/- 8 MPa and 500 +/- 10 MPa, respectively, 23% and 32% higher than Ti16Zr alloy. The enhanced strength of Ti50Zr alloy is attributed to multiple mechanisms, including acicular martensite strengthening, Zr solid solution strengthening, nano-twins and dislocations strengthening. The maximum cycling loads of Ti50Zr implants in air, artificial saliva solution and with sand blasting plus acid etching (SLA) treated surface reach 400 N, 400 N and 350 N (5 x 10(6) cycles without failure), respectively, 33%similar to 75% higher than Ti16Zr implants. High surface roughness harms the fatigue performance of the Ti-Zr implants owing to the promotion role of notch-type defects to fatigue crack initiation. A corrosion-assisted fatigue process in artificial saliva solution under large load reduces the fatigue life of the Ti-Zr implants. Ti50Zr alloy is an ideal candidate material applied for dental implant with regards to its good biocompatibility, excellent mechanical properties and economic processing route. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:212 / 219
页数:8
相关论文
共 35 条
[1]   Corrosion fatigue of biomedical metallic alloys: Mechanisms and mitigation [J].
Antunes, Renato Altobelli ;
Lopes de Oliveira, Mara Cristina .
ACTA BIOMATERIALIA, 2012, 8 (03) :937-962
[2]   Fatigue life estimation in dental implants [J].
Ayllon, J. M. ;
Navarro, C. ;
Vazquez, J. ;
Dominguez, J. .
ENGINEERING FRACTURE MECHANICS, 2014, 123 :34-43
[3]   Reliability and failure modes of implant-supported zirconium-oxide fixed dental prostheses related to veneering techniques [J].
Baldassarri, Marta ;
Zhang, Yu ;
Thompson, Van P. ;
Rekow, Elizabeth D. ;
Stappert, Christian F. J. .
JOURNAL OF DENTISTRY, 2011, 39 (07) :489-498
[4]   MARTENSITIC TRANSFORMATION IN ZR-TI ALLOYS [J].
BANERJEE, S ;
KRISHNAN, R .
METALLURGICAL TRANSACTIONS, 1973, 4 (08) :1811-1819
[5]   Failure Analysis of Titanium-Based Dental Implant [J].
Barbosa, Cassio ;
do Nascimento, Joneo Lopes ;
Centeno, Robson Oliveira ;
Vieira Caminha, Ieda Maria ;
Abud, Ibrahim de Cerqueira .
JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2010, 10 (02) :138-142
[6]   A pilot study to evaluate the success and survival rate of titanium-zirconium implants in partially edentulous patients: results after 24 months of follow-up [J].
Barter, Stephen ;
Stone, Paul ;
Braegger, Urs .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (07) :873-881
[7]  
Bernhard N., 2009, FORUM IMPLANTOL, V5, P30
[8]  
Courtney Thomas., 2000, MECH BEHAV MAT
[9]   R&D on dental implants breakage [J].
Croitoru, Sorin Mihai ;
Popovici, Ion Alexandru .
APPLIED SURFACE SCIENCE, 2017, 417 :262-268
[10]  
Elias CN., 2013, J Mater Res Technol, V2, P340, DOI DOI 10.1016/J.JMRT.2013.07.003