Inner-volume imaging in vivo using three-dimensional parallel spatially selective excitation

被引:38
作者
Schneider, Johannes T. [1 ,2 ]
Kalayciyan, Raffi [1 ]
Haas, Martin [2 ]
Herrmann, Sarah R. [1 ]
Ruhm, Wolfgang [1 ]
Hennig, Juergen [2 ]
Ullmann, Peter [1 ]
机构
[1] Bruker BioSpin MRI GmbH, DE-76275 Ettlingen, Germany
[2] Univ Med Ctr Freiburg, Dept Radiol, Freiburg, Germany
关键词
inner-volume imaging; parallel excitation; multidimensional spatially selective excitation pulses; three-dimensional k-space trajectory; K-SPACE; RF PULSES; MR-ANGIOGRAPHY; TRANSMISSION; TRAJECTORIES; DESIGN; LOCALIZATION; SPECTROSCOPY; CHANNELS; ECHO;
D O I
10.1002/mrm.24381
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This work describes the first experimental realization of three-dimensional spatially selective excitation using parallel transmission in vivo. For the design of three-dimensional parallel excitation pulses with short durations and high excitation accuracy, the choice of a suitable transmit k-space trajectory is crucial. For this reason, the characteristics of a stack-of-spirals trajectory and of a concentric-shells trajectory were examined in an initial simulation study. It showed that, especially when undersampling the trajectories in combination with parallel transmission, experimental parameters such as transmit-coil geometry and off-resonance conditions have an essential impact on the suitability of the selected trajectory and undersampling scheme. Both trajectories were applied in MR inner-volume imaging experiments which demonstrate that acceptably short and robust three-dimensional selective pulses can be achieved if the trajectory is temporally optimized and its actual path is measured and considered during pulse calculation. Pulse durations as short as 3.2 ms were realized and such pulses were appropriate to accurately excite arbitrarily shaped volumes in a corn cob and in a rat in vivo. Reduced field-of-view imaging of these selectively excited targets allowed high spatial resolution and significantly reduced measurement times and furthermore demonstrates the feasibility of three-dimensional parallel excitation in realistic MRI applications in vivo. Magn Reson Med, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1367 / 1378
页数:12
相关论文
共 46 条
  • [11] SPATIAL LOCALIZATION IN 2 DIMENSIONS USING NMR DESIGNER PULSES
    HARDY, CJ
    CLINE, HE
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1989, 82 (03): : 647 - 654
  • [12] P-31 SPECTROSCOPIC LOCALIZATION USING PINWHEEL NMR EXCITATION PULSES
    HARDY, CJ
    BOTTOMLEY, PA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (02) : 315 - 327
  • [13] k-space and q-space: Combining ultra-high spatial and angular resolution in diffusion imaging using ZOOPPA at 7 T
    Heidemann, Robin M.
    Anwander, Alfred
    Feiweier, Thorsten
    Knoesche, Thomas R.
    Turner, Robert
    [J]. NEUROIMAGE, 2012, 60 (02) : 967 - 978
  • [14] FAST 3-DIMENSIONAL MAGNETIC-RESONANCE-IMAGING
    IRARRAZABAL, P
    NISHIMURA, DG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) : 656 - 662
  • [15] Flow properties of fast three-dimensional sequences for MR angiography
    Irarrázaval, P
    Santos, JM
    Guarini, M
    Nishimura, D
    [J]. MAGNETIC RESONANCE IMAGING, 1999, 17 (10) : 1469 - 1479
  • [16] Transmit SENSE
    Katscher, U
    Börnert, P
    Leussler, C
    van den Brink, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) : 144 - 150
  • [17] Kokorin D, 2011, P 19 ANN M ISMRM MON, P3782
  • [18] A fast method for designing time-optimal gradient waveforms for arbitrary k-space trajectories
    Lustig, Michael
    Kim, Seung-Jean
    Pauly, John A.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (06) : 866 - 873
  • [19] Tailored excitation in 3D with spiral nonselective (SPINS) RF pulses
    Malik, Shaihan J.
    Keihaninejad, Shiva
    Hammers, Alexander
    Hajnal, Joseph V.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (05) : 1303 - 1315
  • [20] MULTI-PLANAR IMAGE-FORMATION USING NMR SPIN ECHOES
    MANSFIELD, P
    [J]. JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1977, 10 (03): : L55 - L58